Building Components & Lead Paint Inspection Flashcards

6 cards from real EPA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Building Components & Lead Paint Inspection flashcards as text
  1. Which building component is most commonly associated with lead-based paint hazards in pre-1978 housing?

    Answer: Interior trim, window frames, and door frames

    Interior trim, windows, and doors are prime locations for lead-based paint because contractors historically used durable oil-based lead paint on high-wear surfaces.

  2. What device is the standard tool for non-destructive lead testing in the field?

    Answer: X-ray fluorescence (XRF) analyzer

    XRF analyzers use X-ray fluorescence to measure lead concentration in paint layers without destroying the surface, providing immediate results on-site.

  3. Under EPA regulations, what is the lead concentration threshold that defines paint as 'lead-based paint'?

    Answer: 1.0 mg/cm² or 0.1% by weight

    EPA defines lead-based paint as paint containing 1.0 mg/cm² or more by XRF measurement, or 0.1% or more by weight from laboratory analysis.

  4. When using paint chip sampling to test for lead, where should samples be collected from?

    Answer: Through all paint layers down to the substrate

    Paint chip samples must include all paint layers down to the bare substrate to capture any lead-based paint that may be covered by subsequent non-lead paint coats.

  5. Which type of surface testing is allowed as a presumptive determination of lead-based paint without laboratory analysis?

    Answer: Certified XRF measurement at or above 1.0 mg/cm²

    An EPA-recognized XRF instrument measuring 1.0 mg/cm² or above is a definitive field measurement; colorimetric tests can indicate presence but XRF provides a regulatory-grade determination.

  6. In a lead inspection report, which component designations must be recorded for each tested surface?

    Answer: Room, component type, substrate material, test result, and lead-based paint determination

    EPA lead inspection reports must document each tested component with room location, component type, substrate, the test result, and whether the surface is defined as lead-based paint.