  1. Under OSHA 1926.501, at what height must construction workers on a rooftop solar job be protected from falls?

    Answer: 6 feet

    OSHA construction standards require fall protection at 6 feet or more above a lower level.

  2. What is the required top-rail height of a guardrail system under OSHA construction standards?

    Answer: 42 inches ± 3 inches

    OSHA 1926.502(b) requires guardrail top rails at 42 inches, plus or minus 3 inches.

  3. An anchorage for a personal fall arrest system must support at least how much load per attached employee if not designed by a qualified person?

    Answer: 5,000 lb

    OSHA requires PFAS anchorages to support 5,000 lb per employee or be designed with a safety factor of two by a qualified person.

  4. Under NFPA 70E, the arc flash boundary is the distance at which incident energy equals what value?

    Answer: 1.2 cal/cm²

    The arc flash boundary is where incident energy reaches 1.2 cal/cm², the onset of a second-degree burn.

  5. Which OSHA standard governs the control of hazardous energy (lockout/tagout) during service of equipment like inverters?

    Answer: 29 CFR 1910.147

    29 CFR 1910.147 is OSHA's control of hazardous energy (lockout/tagout) standard.

  6. OSHA limits the free-fall distance in a personal fall arrest system to a maximum of how many feet?

    Answer: 6 feet

    Personal fall arrest systems must be rigged so a worker cannot free fall more than 6 feet.

  7. When a portable ladder is used to access a roof, how far must its side rails extend above the upper landing surface?

    Answer: 3 feet

    OSHA 1926.1053 requires ladder side rails to extend at least 3 feet above the landing.