Photovoltaic (PV) System Design Flashcards
7 cards from real SE ENGR. practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Photovoltaic (PV) System Design flashcards as text
An off-grid home uses 6 kWh/day and needs 3 days of autonomy with a 50% maximum depth of discharge on a 48 V battery bank. What is the required capacity?
Answer: 750 Ah
6 kWh × 3 days ÷ 0.5 = 36 kWh, and 36,000 Wh ÷ 48 V = 750 Ah.
What is a key advantage of an MPPT charge controller over a PWM controller?
Answer: It can run the array at a higher voltage than the battery and convert the extra voltage into charging current
MPPT controllers step down array voltage with a DC-DC converter, recovering energy that a PWM controller would waste.
Which site factor has the biggest effect on energy gain from bifacial modules?
Answer: Ground surface albedo
The rear side collects reflected light, so a high-albedo surface such as white gravel or snow greatly increases bifacial gain.
How is ground coverage ratio (GCR) defined for a row-based array?
Answer: Collector width (slant length) divided by row pitch
GCR is the collector's width along the slope divided by the row-to-row pitch, so a higher GCR means denser rows and more inter-row shading.
Which standard is typically used in the US to determine wind and snow design loads on PV array structures?
Answer: ASCE 7
ASCE 7 sets minimum design loads, including wind and snow, which the building codes reference for PV structures.
How is a PV cell's fill factor defined?
Answer: Pmax ÷ (Voc × Isc)
Fill factor compares actual maximum power with the product of open-circuit voltage and short-circuit current, showing how 'square' the I-V curve is.
Compared with a fixed-tilt array, about how much more annual energy does a single-axis tracker typically produce at a sunny US site?
Answer: 15–25%
Single-axis trackers usually add about 15–25% annual energy by following the sun from east to west.