← All NATE Flashcard Decks

Gas Heating Flashcards

6 cards from real NATE practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Gas Heating flashcards as text
  1. What is the primary safety device that shuts off the gas valve if the pilot flame is extinguished on a standing pilot furnace?

    Answer: Thermocouple

    The thermocouple generates a small millivolt signal that holds the gas valve open; when the pilot goes out the signal drops and the valve closes.

  2. What is the purpose of the heat exchanger in a gas furnace?

    Answer: Transfer heat from combustion gases to the circulating air without mixing them

    The heat exchanger keeps combustion products separated from conditioned air while allowing heat transfer through the metal walls.

  3. What component in an induced-draft furnace proves that combustion airflow is established before the gas valve opens?

    Answer: Pressure switch

    The pressure switch senses negative pressure created by the inducer motor to confirm draft is established before allowing ignition.

  4. What type of ignition system uses a glowing ceramic element to ignite the gas burners in modern furnaces?

    Answer: Hot surface igniter (HSI)

    Hot surface igniters heat to approximately 1800–2500°F using electricity to ignite the gas burner, replacing standing pilots.

  5. What is the function of the rollout switch on a gas furnace?

    Answer: Detect flame rollout and shut down the furnace if heat exceeds safe limits near the burner compartment

    Rollout switches are manual-reset thermal devices that trip if flames exit the burner compartment, indicating a serious combustion problem.

  6. What is the standard gas manifold pressure for natural gas residential furnaces in the US?

    Answer: 3.2–3.8 inches WC

    Natural gas furnace manifold pressure is typically set at 3.2–3.8 inches water column (around 3.5 inches WC nominal).