Safety Procedures & Code Compliance Flashcards
7 cards from real NEC practice questions. Tap to flip, then mark Knew It or Still Learning โ missed cards come back until you master them.
Read the first 7 Safety Procedures & Code Compliance flashcards as text
Per NEC 210.8(A), GFCI protection is required for 125V receptacles in which residential location?
Answer: Bathrooms
NEC 210.8(A) lists bathrooms among locations requiring GFCI protection.
What device protects against arcing faults that can cause fires, required in dwelling bedrooms?
Answer: AFCI
AFCI (Arc-Fault Circuit Interrupter) detects dangerous arcing and is required in bedrooms per NEC 210.12.
What is the maximum overcurrent protection for a 12 AWG copper conductor under normal conditions?
Answer: 20 amps
NEC 240.4(D) limits 12 AWG copper to 20 amps overcurrent protection.
Per NEC, what color is reserved for the equipment grounding conductor?
Answer: Green or green with yellow stripe
NEC 250.119 identifies equipment grounding conductors as green or green with a yellow stripe.
What is required where a panelboard is installed, regarding the directory?
Answer: Legibly identify the purpose of each circuit
NEC 408.4 requires each circuit to be legibly identified as to its purpose.
When using a portable ladder near energized electrical equipment, which material is safest?
Answer: Fiberglass
Fiberglass ladders are non-conductive, making them safest near energized equipment.
What is the minimum burial depth for direct-buried UF cable rated 0-600V under a residential driveway per NEC Table 300.5?
Answer: 18 inches
NEC Table 300.5 requires 18 inches of cover for direct-buried cable in most residential conditions.