  1. Under the IPC, what is the required test pressure for a new water distribution system before it is put into service?

    Answer: 100 psi for 15 minutes

    The IPC requires new water distribution systems to be tested at 100 psi for a minimum of 15 minutes without leakage.

  2. Which code section of the IPC specifically governs storm drainage systems?

    Answer: Chapter 10

    IPC Chapter 10 covers storm drainage, including roof drains, leaders, and storm sewer connections.

  3. According to the IPC, a floor drain installed in a parking garage must be connected to:

    Answer: A sand/oil interceptor before the sewer

    Parking garage floor drains must discharge through a sand and oil interceptor to remove petroleum products before entering the sewer.

  4. Under model plumbing codes, what is the minimum number of fixture units a 4-inch vertical soil stack can carry?

    Answer: 256 DFU

    Per IPC Table 710.1, a 4-inch vertical stack can carry 256 drainage fixture units.

  5. The IPC requires that vent pipes penetrating a roof extend a minimum of how far above the roof surface in areas subject to frost?

    Answer: 12 inches

    In frost areas the IPC requires vent terminals to extend at least 12 inches above the roof to prevent frost closure.

  6. Per OSHA and plumbing codes, a plumber working in a trench deeper than 5 feet must ensure the trench is:

    Answer: Sloped, shored, or shielded

    OSHA 29 CFR 1926.652 requires trenches 5 feet or deeper to be sloped, shored, or protected with a trench shield.

  7. Which of the following fixtures does NOT require a trap under model plumbing codes?

    Answer: Water closet

    Water closets have an integral trap built into the bowl and do not require a separate external trap.