  1. Under the National Plumbing Code of the Philippines (NPCP), what is the minimum trap seal depth required for fixture traps?

    Answer: 38 mm (1.5 inches)

    The NPCP requires a minimum trap seal depth of 38 mm (1½ inches) to prevent sewer gases from entering the building.

  2. According to the Philippine Sanitation Code (PD 856), what is the minimum distance between a deep well and a septic tank?

    Answer: 25 meters

    PD 856 requires a minimum horizontal distance of 25 meters between a deep well and a septic tank to prevent contamination of the water supply.

  3. In the NPCP, what is the fixture unit (FU) value assigned to a lavatory (washbasin) for drainage load calculation?

    Answer: 1 FU

    A lavatory is assigned 1 fixture unit for drainage load calculations under the NPCP.

  4. What does 'PN6' designation mean for PVC pressure pipes used in water supply systems in the Philippines?

    Answer: Pressure Nominal rating of 6 bar (600 kPa)

    PN6 stands for Pressure Nominal 6 bar, meaning the pipe is rated for a maximum working pressure of 600 kPa (approximately 87 psi).

  5. Under the NPCP, what is the maximum trap arm length (distance from trap weir to vent) for a 38 mm (1½-inch) drain pipe?

    Answer: 1.5 m (5 ft)

    For a 38 mm diameter drain pipe, the maximum trap arm length is 1.5 m (approximately 5 feet) per the NPCP.

  6. According to the NPCP, what minimum size vent pipe is required for a water closet?

    Answer: 50 mm (2 inches)

    A water closet requires a minimum 50 mm (2-inch) individual vent pipe under the NPCP.

  7. What is the minimum number of water closets required per 100 male employees in a factory or industrial establishment under the Philippine Sanitation Code?

    Answer: 2

    The Philippine Sanitation Code requires a minimum of 2 water closets per 100 male employees in factories and industrial establishments.