  1. Which of the following fixtures is assigned the highest drainage fixture unit (DFU) value under the IPC?

    Answer: Water closet (flush tank)

    A flush-tank water closet is rated at 3 DFUs, which is higher than a lavatory (1), bathtub (2), or kitchen sink (2).

  2. What type of vent is installed downstream of a fixture trap and connects to the vent stack above the fixture's flood level rim?

    Answer: Individual vent (back vent)

    An individual vent (also called a back vent or revent) connects the fixture's trap arm to the vent stack and runs upward past the fixture's flood level rim.

  3. An island fixture vent loop is required when:

    Answer: A sink or similar fixture is installed in an island where a standard vent cannot go up through a wall

    Island fixture vent loops route the vent piping under the floor and back up alongside the drain when there is no adjacent wall to run a conventional vent.

  4. What is the minimum size of a vent stack serving a soil stack that receives discharge from water closets?

    Answer: 3 inches

    When water closets connect to the soil stack, the vent stack must be at least 3 inches in diameter per IPC sizing requirements.

  5. A crown vent is prohibited because:

    Answer: Solids can accumulate and block the vent opening at the top of the trap

    A crown vent connects at the crown (top) of the trap, where waste material can collect and plug the vent, rendering it ineffective.

  6. Under the IPC, a vent pipe that terminates through an exterior wall must terminate at least how far above the top of the opening it is near?

    Answer: 6 inches

    A vent terminating through an exterior wall must end at least 6 inches above the top of any nearby opening such as a window or door.

  7. Which of these conditions would cause a trap to lose its water seal due to self-siphonage?

    Answer: A fixture drain discharges a full slug of water through a long, unvented trap arm

    Self-siphonage occurs when a full flow of water down an unvented or inadequately vented trap arm creates enough suction to pull the water seal out of the trap.