โ† All HSPA Flashcard Decks

Sterilization and Disinfection Flashcards

5 cards from real HSPA practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 5 Sterilization and Disinfection flashcards as text
  1. What is the most commonly used method for sterilizing surgical instruments in healthcare facilities?

    Answer: Steam sterilization

    Steam sterilization, also known as autoclaving, is the most commonly used and reliable method for sterilizing heat- and moisture-stable surgical instruments in healthcare facilities. Its effectiveness stems from its ability to rapidly kill microorganisms through heat and moisture, making it efficient and cost-effective for a wide range of medical devices.

  2. Which of the following is critical for ensuring effective steam sterilization?

    Answer: Achieving the correct combination of time, temperature, and pressure

    Effective steam sterilization relies on a precise balance of time, temperature, and pressure to ensure all microorganisms are destroyed. Insufficient exposure to any of these parameters can lead to incomplete sterilization, posing a risk to patient safety. Adhering to validated cycles is paramount for successful outcomes.

  3. What type of item is most suitable for hydrogen peroxide gas plasma sterilization?

    Answer: Heat-sensitive medical equipment

    Hydrogen peroxide gas plasma sterilization is a low-temperature method specifically designed for heat- and moisture-sensitive medical devices that cannot withstand steam sterilization. This method effectively sterilizes instruments without causing damage, making it ideal for delicate electronics, cameras, and certain plastics.

  4. Which indicator is used to confirm that sterilization conditions were met in a sterilizer?

    Answer: Biological indicator (BI)

    A biological indicator (BI) is the only process monitoring device that directly measures the lethality of a sterilization process by using highly resistant bacterial spores. A negative BI result confirms that the conditions within the sterilizer were sufficient to kill even the most resistant microorganisms, providing the highest level of assurance for sterilization.

  5. What is the recommended procedure for cleaning instruments before sterilization?

    Answer: Use enzymatic detergent and follow manufacturer instructions

    Proper cleaning is the critical first step in reprocessing instruments, as sterilization cannot compensate for inadequate cleaning. Enzymatic detergents are highly effective at breaking down organic matter like blood and tissue, and following the instrument manufacturer's Instructions for Use (IFU) ensures the correct method and agents are used to prevent damage and achieve thorough decontamination.