  1. During a home inspection, the inspector observes that wood structural members in the crawl space show evidence of wood-boring beetle activity. Which sign BEST distinguishes active infestation from old, inactive damage?

    Answer: Fresh, powdery frass and clean exit holes indicate active beetles

    Fresh, fine powdery frass and bright, clean-edged exit holes indicate active wood-boring beetles, while old holes are typically darker and lack fresh frass.

  2. A home inspector finds that several floor joists have been bored with large holes near their ends to run HVAC ducts. What structural principle explains why this location is particularly problematic?

    Answer: Shear forces are highest near the ends of joists, so holes reduce shear capacity

    Shear stress is greatest near the supports (ends) of a beam, so holes in this zone significantly reduce the joist's ability to resist vertical forces.

  3. What is the purpose of a 'let-in brace' in wood-frame wall construction?

    Answer: A diagonal board notched into studs to provide lateral (shear) resistance

    A let-in brace is a diagonal 1x4 board notched flush into studs to stiffen the wall against racking caused by lateral (wind or seismic) loads.

  4. A home inspector finds that a second-floor bedroom was added above a garage, but the garage door header appears to be a single 2x10. What is the likely concern?

    Answer: A single 2x10 is typically undersized to carry the additional live and dead loads from the floor above

    A wide garage opening with an added floor above requires a much larger header or beam to carry the additional loads without excessive deflection.

  5. When inspecting an older home, a home inspector observes that the floor joists rest directly on the foundation sill plate but no metal anchor bolts are visible at the sill. What hazard does this present?

    Answer: The floor and wall framing can slide or lift off the foundation during high winds or seismic events

    Anchor bolts connect the sill plate to the foundation, preventing the entire structure from sliding or lifting off during lateral forces such as wind or earthquakes.

  6. A home inspector notices that a load-bearing stud wall has been framed with 2x3 studs instead of 2x4 studs at 16 inches on center. What is the PRIMARY structural concern?

    Answer: 2x3 studs have significantly less load-carrying capacity and are not typically permitted for load-bearing walls

    2x3 studs have substantially reduced cross-sectional area and column strength, making them inadequate for load-bearing applications under most building codes.

  7. A home inspector observes that roof trusses have been field-modified by a homeowner to create attic storage space — specifically, the bottom chord has been cut and a small room framed in. What is the structural implication?

    Answer: Cutting truss members destroys the engineered load path and can lead to truss failure

    Trusses are engineered systems where every member carries specific tension or compression forces; cutting any member without re-engineering can cause collapse.