← All HERS Flashcard Decks

Rating Standards & Compliance Flashcards

7 cards from real HERS practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Rating Standards & Compliance flashcards as text
  1. For a multifamily building with three or fewer stories, which HERS rating standard applies?

    Answer: ANSI/RESNET/ICC 301 for low-rise residential

    Low-rise multifamily buildings (three stories or fewer above grade) are rated under ANSI/RESNET/ICC 301, the same standard as single-family homes.

  2. A builder asks a HERS rater to rate only the insulation and air sealing and skip duct testing to save time. The rater should:

    Answer: Decline — a confirmed rating requires all required inspections and tests

    RESNET standards require all mandatory inspections and tests to be completed for a valid confirmed rating; partial ratings are not permissible.

  3. Under RESNET's HERS rating standards, 'thermal bypass' defects discovered during inspection must be:

    Answer: Documented as-built and included in the rating model accurately

    All as-built conditions including thermal bypasses must be documented and modeled accurately regardless of their effect on the final HERS score.

  4. A HERS rater's certification lapses due to missed continuing education requirements. What is the immediate consequence?

    Answer: The rater cannot perform or submit HERS ratings until recertification is complete

    A lapsed HERS certification means the rater is not authorized to perform or submit ratings until all recertification requirements are fulfilled.

  5. Which aspect of a home's window specifications is directly input into HERS rating software to calculate energy performance?

    Answer: U-factor and Solar Heat Gain Coefficient (SHGC)

    HERS rating software requires window U-factor (thermal conductance) and SHGC (solar gain) values to calculate heating, cooling, and lighting loads.

  6. When a home's heating system is not yet installed at the time of the confirmed rating, the rater should:

    Answer: Postpone the confirmed rating until the system is installed and tested

    A confirmed rating requires all systems to be installed and verifiable; the rating must be postponed until the heating system is installed.

  7. What is the RESNET-defined role of a 'Rating Provider' in the HERS certification ecosystem?

    Answer: An accredited organization responsible for training, certifying, and quality-assuring HERS raters

    RESNET-accredited Rating Providers are the organizational backbone of the HERS system, responsible for rater training, certification, quality assurance, and file management.