F60 Cheat Sheet 2026
The 30 highest-yield F60 facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
25 questions
30 min time limit
70% to pass
- Under FDNY rules, who is responsible for ensuring a properly rated fire extinguisher is present during torch operations? → The Certificate of Fitness (F-60) holder on site
- Under FDNY rules, a fire guard conducting a fire watch must be within what proximity of the torch work? → Within sight of the torch operations at all times
- Under the F60 certificate requirements, the fire guard must inspect the hot work area how often during active torch operations? → Continuously throughout the operation
- Who is authorized to issue a hot work permit for torch operations in New York City? → The building owner or their designated representative
- Under NYC fire code, how long before expiration should a torch operations fire guard ideally begin the certificate renewal process? → At least 60 to 90 days before expiration
- A torch-related fire has been extinguished with a portable extinguisher. Why must the fire guard still call 911? → Concealed smoldering may remain undetected and reignite without FDNY inspection
- How should a fire guard document the fire watch period at the completion of torch operations? → Enter the start time, end time, and observations in the required log or permit
- What must the fire guard do if a fire starts during torch operations and cannot be controlled with available extinguishers? → Activate the fire alarm, call 911, and initiate building evacuation procedures
- The F-60 certificate holder is required to remain on-site during torch operations for what purpose? → To act as a fire guard and monitor for fire hazards
- Before signing the hot work permit, the fire watch must verify that: → A fire extinguisher is fully charged and within reach of the work area
- How long is the Fire Guard for Torch Operations certificate typically valid? → 3 years
- What is the maximum duration typically allowed for a single hot work permit before it must be renewed? → One shift or one day
- Which of the following best describes 'kindling temperature' as it applies to torch operations? → The minimum temperature at which a material will self-sustain combustion
- Which of the following best describes the fire guard's responsibility regarding access points and exits in the work area? → Exits must remain unobstructed and accessible for emergency evacuation at all times
- How must a fire guard document the completion of their fire watch duties? → By completing a fire watch log recording the work performed, times, and observations
- Before torch operations begin each day, what must the fire guard inspect? → The work area for combustible and flammable materials that must be removed or protected
- When torch operations take place within 10 feet of a fire door, the fire guard must verify that the fire door: → Remains fully operational and is not blocked or wedged open
- Halon extinguishers are no longer commonly used in new installations primarily because: → Halon damages the ozone layer and its production is banned
- Which of the following is a required element in a fire watch log entry when torch operations are underway? → The name and C of F number of the Fire Guard on duty
- When a fire guard is assigned to a torch operation on a roof, what is the minimum required watch period after the torch work is completed? → 1 hour
- When a fire guard discovers a fire that cannot be immediately extinguished, what is the FIRST action to take? → Activate the building fire alarm
- Which extinguisher is appropriate for a fire in a propane cylinder valve area during torch operations? → Dry chemical extinguisher rated B:C — to suppress the gas fire
- After successfully extinguishing a fire with a dry chemical extinguisher, what critical follow-up step must the fire guard perform? → Watch for re-ignition and ensure the area is monitored for at least one hour
- Which of the following is a mandatory storage requirement for compressed gas cylinders when they are not in use on a job site? → Protected from the direct rays of the sun.
- Under NYC Building Code, hot work permits on construction sites are typically valid for what maximum duration? → One calendar day
- What action must the fire guard take if combustible materials cannot be relocated away from the hot work zone on a construction site? → Use fire-resistant barriers or shields to protect the materials in place
- What is the fire guard's role when FDNY inspectors arrive at an active torch operation site? → Present their Certificate of Fitness and cooperate fully with the inspection
- A fire guard notices a small fire starting in a wall cavity near a torch operation. What is the FIRST action the fire guard should take? → Attempt to extinguish the fire with available means and notify the supervisor
- What does the 'B' rating on a fire extinguisher indicate? → Square footage of Class B fire it can extinguish
- The F60 certificate scope applies primarily to prevent fires caused by heat transfer from torches to which types of materials? → Combustible substrates, insulation, wood framing, and debris
Turn these facts into recall: