What must a fire guard do if they find a required exit door locked during an event?
Answer: Immediately unlock the door and notify the fire safety director
Required exit doors must never be locked during occupancy. If a fire guard discovers a locked exit, they must immediately unlock it and notify the fire safety director. Keeping exits locked during an event is a serious fire code violation that endangers occupant lives.
What is the minimum clear width required for aisles leading to exits in places of assembly?
Answer: 36 inches
Aisles serving seating in places of assembly must maintain a minimum clear width of 36 inches to allow safe egress during an emergency. Fire guards must ensure aisles remain free of obstructions including chairs, equipment, and standing guests.
Which of the following is an acceptable use of a required exit corridor in a place of assembly?
Answer: Free and unobstructed passage for occupants to reach exits
Required exit corridors must be kept clear at all times and used only for free and unobstructed passage of occupants to exits. Using corridors for storage, dining, or other purposes that impede egress is prohibited.
What must happen to exit signs in a place of assembly if the primary lighting fails?
Answer: Exit signs must illuminate automatically from an independent emergency power source
Exit signs in places of assembly must be connected to an emergency power supply that activates automatically if primary power fails. This ensures occupants can always locate exits even during a power outage, which may occur during a fire or emergency.
When may a device that requires a key or special knowledge to open be installed on a required exit door?
Answer: Only if a delayed-egress or alarm-activating device is approved for the specific occupancy
Certain code-approved delayed-egress or access-control devices may be permitted on exits in specific occupancies under FDNY and Building Code approval. These devices are designed to sound an alarm and release quickly in emergencies. Simple key locks on required exits during occupancy are never permitted.
What should a fire guard do when they observe guests standing in or blocking an aisle during an event?
Answer: Politely but firmly direct guests to clear the aisle immediately
A fire guard must immediately and politely direct guests blocking aisles to move. Aisle clearance is a life-safety requirement — blocked aisles can prevent rapid egress during an emergency and constitute a fire code violation.