← All EPA 609 Flashcard Decks

Refrigerant Recovery & Recycling Flashcards

6 cards from real EPA 609 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Refrigerant Recovery & Recycling flashcards as text
  1. What type of container must recovered refrigerant be stored in?

    Answer: DOT-approved recovery cylinders that are clearly labeled

    Recovered refrigerant must be stored in DOT-approved recovery cylinders that are properly labeled with the refrigerant type and recovery date.

  2. Can R-134a and R-12 be mixed in the same recovery cylinder?

    Answer: No — different refrigerants must NEVER be mixed

    Mixing refrigerants creates a contaminated blend that is extremely difficult to separate and reclaim, and may damage the reclaimer's equipment.

  3. What must technicians do if they discover that a vehicle's A/C system contains a refrigerant other than what is labeled?

    Answer: Recover it into a separate cylinder for contaminated refrigerant

    Unknown or mixed refrigerants must be recovered into a dedicated 'contaminated' or 'unknown' cylinder to prevent cross-contamination.

  4. Recovery cylinders must be checked and retired when they reach:

    Answer: Their retest date or show signs of damage/corrosion

    DOT recovery cylinders must be hydrostatically retested periodically (typically every 5 years) and retired if damaged or past their retest date.

  5. The maximum fill level for refrigerant recovery cylinders is:

    Answer: 80% of water capacity by weight

    Recovery cylinders must never be filled beyond 80% of their water capacity by weight to allow for refrigerant expansion.

  6. Which equipment is required for MVAC refrigerant service under Section 609?

    Answer: Recovery/recycling or recovery-only equipment certified to SAE J2788

    Technicians must use recovery or recovery/recycling equipment that meets SAE J2788 certification to comply with EPA Section 609.