System Sizing & Design Flashcards
7 cards from real CWS practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 System Sizing & Design flashcards as text
A sediment filter with a 20-micron cartridge is placed before a 5-micron cartridge in a multi-stage system. This arrangement is called:
Answer: Series depth filtration with graded porosity
Graded porosity in series filtration progressively removes larger particles first to protect finer downstream media from premature loading.
For a residential RO system rated at 50 gallons per day (GPD), approximately how long will it take to fill a standard 3.2-gallon storage tank to 75% capacity under typical pressure conditions?
Answer: Approximately 1.4 hours
50 GPD ÷ 24 hours ≈ 2.08 GPH; filling 2.4 gallons (75% of 3.2 gal) takes 2.4 ÷ 2.08 ≈ 1.15 hours, or about 1.4 hours accounting for declining production as tank pressure rises.
Which of the following best describes the purpose of a bypass valve assembly in a water treatment system design?
Answer: To allow service or replacement of equipment without interrupting water supply
A bypass valve lets untreated water flow directly to the home while the treatment unit is offline for service or replacement.
When designing a system to remove nitrates by ion exchange, why must the resin be specifically a strong base anion (SBA) resin rather than a standard cation softening resin?
Answer: Nitrate is an anion and requires an anion exchange resin to be captured
Nitrate (NO₃⁻) is a negatively charged anion, so it can only be exchanged by an anion exchange resin, not a cation resin.
A water system serving an 8-unit apartment building needs to be designed. Compared to sizing for a single-family home with the same total fixtures, what design adjustment is most important?
Answer: Apply a diversity factor, as not all fixtures in all units will run simultaneously
A diversity (coincidence) factor is applied to multi-unit buildings because statistical probability of all fixtures running simultaneously is much lower than in a single unit.
In a twin-tank alternating softener system, what is the main operational advantage over a single-tank system?
Answer: Continuous soft water supply with no hardness breakthrough during regeneration
When one tank regenerates, the second tank remains in service, ensuring uninterrupted soft water delivery with no hardness slip.
A designer is specifying pipe size for a whole-house treatment system. The source water contains high iron and the system will include a backwashing iron filter. What pipe material should generally be AVOIDED in downstream distribution?
Answer: Galvanized steel
Galvanized steel pipe can leach zinc and corrode when residual dissolved iron oxidizes inside the pipe, causing rust staining and flow restrictions.