Codebook Navigation and Application Flashcards
7 cards from real CWI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Codebook Navigation and Application flashcards as text
In AWS D1.1, which section contains the prequalified joint detail tables for complete joint penetration groove welds?
Answer: Section 4
Section 4 of AWS D1.1 covers prequalified WPS requirements including the joint detail tables for CJP groove welds.
When AWS D1.1 lists a requirement as 'shall,' this indicates the requirement is:
Answer: Mandatory
In AWS codes, 'shall' denotes a mandatory requirement, whereas 'should' denotes a recommendation.
Which AWS D1.1 table is used to determine the minimum preheat and interpass temperature for a given base metal and thickness?
Answer: Table 4.5
Table 4.5 in AWS D1.1 provides minimum preheat and interpass temperature requirements based on base metal category and thickness.
A CWI needs to verify fillet weld size acceptance criteria. In AWS D1.1, where would this information be found?
Answer: Section 6 — Inspection
Section 6 (Inspection) contains the visual inspection acceptance criteria including fillet weld size tolerances.
In AWS D1.1, Annex A is normative. What does 'normative' mean for an annex?
Answer: It is mandatory and part of the code requirements
A normative annex contains mandatory requirements just like the main body of the code, unlike informative annexes which are for guidance only.
Which symbol in AWS D1.1 figures indicates that a dimension or variable is the same as shown in a referenced figure?
Answer: A circle with a letter
AWS D1.1 uses circled letters (callouts) to cross-reference dimensions between figures and corresponding tables.
When performing a code search for the maximum allowable undercut in a statically loaded tension member per AWS D1.1, which section should the inspector consult first?
Answer: Section 6 — Inspection
Weld discontinuity acceptance criteria, including undercut limits, are located in Section 6 under visual inspection requirements.