OR Setup & Room Turnover Flashcards

7 cards from real CST practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 OR Setup & Room Turnover flashcards as text
  1. Which of the following is the CORRECT sequence for donning sterile attire before a case?

    Answer: Gown, then gloves

    The gown is donned first because the hands must remain uncontaminated to open and position the gown; gloves are then applied over the gown cuffs.

  2. A case cart delivered to the OR contains a package with an expired sterilization date. The scrub tech should:

    Answer: Return the item, obtain a replacement, and notify the charge nurse

    Expired sterilization dating means sterility cannot be guaranteed; the item must be replaced and the incident reported.

  3. The recommended minimum air exchanges per hour in a standard OR to maintain air quality is:

    Answer: 15 exchanges per hour

    AORN and ASHRAE standards recommend a minimum of 15 air exchanges per hour in the OR, with at least 3 being fresh outside air.

  4. When creating a sterile field, the scrub technician should open the back table drape by:

    Answer: Cuffing the drape over gloved hands and unfolding away from the body

    Cuffing the drape over gloved hands protects the sterility of the gloves while the drape is unfolded away from the body to prevent contamination.

  5. Ideally, the back table should be set up how far in advance of the surgical incision?

    Answer: As close to the start of the case as practical; no more than 4 hours before the first incision

    AORN recommends setting up the sterile field as close to the time of use as possible, with 4 hours as an accepted outer limit in most facilities.

  6. Which action BEST maintains the sterility of a wrapped sterile instrument set when opening it onto the back table?

    Answer: Open the outermost flap away from the scrub tech, then side flaps, then near flap

    Opening the far flap first prevents the circulator's arm from passing over the sterile field and maintains directionality away from the scrub tech.

  7. Terminal cleaning of the OR differs from routine between-case cleaning primarily in that terminal cleaning:

    Answer: Includes cleaning all surfaces including walls, ceilings, and equipment, performed at the end of each operative day

    Terminal cleaning is a comprehensive end-of-day cleaning covering all surfaces including walls and overhead equipment to reset the room to baseline cleanliness.