Tonometry and Keratometry Flashcards
7 cards from real COT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Tonometry and Keratometry flashcards as text
Which tonometry method uses a variable force to flatten a fixed area of cornea (3.06 mm diameter)?
Answer: Goldmann applanation tonometry
Goldmann applanation tonometry flattens a fixed 3.06 mm diameter corneal area and varies the force to achieve that area.
What fluorescein pattern indicates the correct endpoint during Goldmann applanation tonometry?
Answer: Two semicircles whose inner edges just touch
The correct endpoint is when the inner edges of the two fluorescein-stained semicircles just touch each other.
A patient has a central corneal thickness of 620 µm. How does this affect Goldmann IOP readings compared to a 545 µm cornea?
Answer: IOP reading is falsely high
Thicker corneas resist applanation more, causing the Goldmann tonometer to overestimate true IOP.
During keratometry, what does the technician measure when aligning the plus (+) and minus (−) mires?
Answer: The radius of curvature of the anterior cornea in two principal meridians
Keratometry measures the radius of curvature of the anterior corneal surface in the flattest and steepest meridians.
A keratometry reading of 44.00 D @ 90° / 46.00 D @ 180° indicates:
Answer: Against-the-rule astigmatism
Against-the-rule astigmatism exists when the steeper meridian is closer to horizontal (180°), meaning more power at 180° than 90°.
Which of the following would cause a falsely LOW IOP reading with non-contact (air-puff) tonometry?
Answer: Patient looking slightly downward
When the patient looks slightly downward, the air puff strikes the peripheral rather than central cornea, yielding an artificially low reading.
The Tono-Pen tonometer is especially useful for which clinical situation?
Answer: Measuring IOP through a bandage contact lens or irregular cornea
The Tono-Pen's small tip makes it ideal for measuring IOP through bandage contact lenses or on irregular corneal surfaces.