  1. Which electrosurgical unit (ESU) mode uses alternating current to simultaneously cut and coagulate tissue?

    Answer: Blend mode

    Blend mode combines cutting and coagulation by interrupting the current cycle, producing both a cutting effect and hemostasis simultaneously.

  2. When preparing a patient for a total hip arthroplasty in the lateral position, which padding is ESSENTIAL to prevent a common positioning injury?

    Answer: Axillary roll placed below the axilla

    An axillary roll placed just below (not in) the axilla protects the brachial plexus and neurovascular structures of the dependent arm.

  3. The CNOR candidate should know that flash (IUSS) sterilization is indicated ONLY when?

    Answer: A sterile item is dropped and no replacement is available

    Immediate use steam sterilization (IUSS) is appropriate only when a needed item is contaminated and no replacement is available, not for implants or routine use.

  4. A surgeon requests the Trendelenburg position for a pelvic laparoscopy. Which physiological effect should the perioperative nurse anticipate?

    Answer: Cephalad shift of the diaphragm

    Trendelenburg causes abdominal viscera and the diaphragm to shift cephalad, reducing lung compliance and functional residual capacity.

  5. Which Spaulding classification applies to a rigid sigmoidoscope that contacts intact mucous membranes but does not penetrate sterile tissue?

    Answer: Semi-critical — requires high-level disinfection

    Semi-critical items contact intact mucous membranes and require high-level disinfection as a minimum standard of reprocessing.

  6. During a laparoscopic cholecystectomy, the surgeon reports difficulty visualizing the operative field. The circulating nurse notes the CO2 insufflation pressure is 25 mmHg. What is the standard maximum safe intraabdominal pressure?

    Answer: 15 mmHg

    The standard safe intraabdominal insufflation pressure for laparoscopy is 15 mmHg; higher pressures increase the risk of cardiovascular and respiratory compromise.

  7. Which action by the scrub person demonstrates CORRECT maintenance of sterile technique during a procedure?

    Answer: Keeping hands at or above waist level at all times

    Scrubbed personnel must keep hands at or above waist level because anything below waist level is considered non-sterile.