โ† All CMI Flashcard Decks

CMI Advanced Diagnostic Methods Flashcards

6 cards from real CMI practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 6 CMI Advanced Diagnostic Methods flashcards as text
  1. What does a thermal imaging camera detect during a home inspection that a standard visual inspection cannot?

    Answer: Temperature differentials that may indicate moisture intrusion, insulation gaps, or electrical hot spots

    Infrared cameras detect surface temperature variations, which can reveal hidden moisture, missing insulation, and overloaded electrical components invisible to the naked eye.

  2. When using a moisture meter during a CMI inspection, a reading above what percentage in wood framing typically indicates a concern requiring further investigation?

    Answer: 19%

    Wood moisture content above 19% creates conditions favorable for wood decay fungi and is the threshold that triggers further investigation or remediation recommendations.

  3. A CMI conducting a blower door test would use the results primarily to assess which building characteristic?

    Answer: Building air leakage and envelope tightness

    A blower door test depressurizes the building to measure air changes per hour (ACH), revealing the overall airtightness of the building envelope.

  4. Which symptom observed during a CMI's roof inspection most strongly suggests active moisture intrusion into the attic?

    Answer: Staining on rafters or sheathing combined with elevated moisture meter readings

    Staining combined with elevated moisture readings provides direct evidence of current or recent water entry, distinguishing active intrusion from old staining.

  5. A CMI inspecting a slab foundation observes diagonal cracking at window and door corners. This pattern most likely indicates which condition?

    Answer: Differential settlement causing stress concentration at structural openings

    Diagonal stair-step or diagonal cracks at openings are classic signs of differential settlement, where one area of the foundation moves more than an adjacent area.

  6. When inspecting a gas-fired forced air furnace, which finding requires the CMI to recommend immediate discontinuation of use?

    Answer: A cracked heat exchanger confirmed by combustion spillage test

    A cracked heat exchanger allows combustion gases including carbon monoxide to mix with supply air and distribute through the home, posing an immediate life-safety hazard.