  1. What is the purpose of performing a static pressure test on a water supply system during a CMI inspection?

    Answer: To verify supply pressure is within the acceptable range of 40–80 psi and check for pressure fluctuations

    Static pressure testing confirms the supply pressure falls within the safe operational range; pressure above 80 psi can damage fixtures and appliances, while low pressure indicates supply problems.

  2. A CMI uses a combustible gas detector near a gas meter and detects a reading. What is the correct immediate action?

    Answer: Leave the property, advise all occupants to evacuate, and contact the gas utility immediately

    A confirmed gas leak is an immediate life-safety emergency requiring evacuation and utility notification before any other action.

  3. When inspecting electrical panels, what does a CMI look for to identify a double-tapped breaker?

    Answer: Multiple conductors (wires) connected to a single breaker terminal not rated for that configuration

    A double-tap occurs when two conductors share one breaker terminal, creating a potential loose connection, overheating, and overcurrent protection failure unless the breaker is rated for multiple conductors.

  4. Which diagnostic technique does a CMI use to differentiate active efflorescence from old, inactive efflorescence on a masonry wall?

    Answer: Test moisture levels with a meter and observe if new deposits are forming at current moisture intrusion points

    Elevated moisture readings near efflorescence deposits and evidence of continuing deposit growth indicate active water migration, while dry readings with stable deposits suggest the condition may be historical.

  5. A CMI inspecting a crawl space observes wood with a cubical cracking pattern throughout the grain. This describes which type of wood decay?

    Answer: Brown rot (dry rot)

    Brown rot (often called dry rot) breaks down cellulose in wood, leaving characteristic cubical or block-like cracking patterns across the grain as the wood shrinks and collapses.

  6. When a CMI is inspecting AFCI (Arc Fault Circuit Interrupter) breaker protection, which circuit locations require AFCI protection under current NEC standards for new US construction?

    Answer: Virtually all 15A and 20A, 120V circuits in dwelling unit living spaces including bedrooms, living rooms, kitchens, and hallways

    The NEC has progressively expanded AFCI requirements to cover nearly all 15A and 20A, 120V branch circuits in dwelling units to protect against arc-fault ignition fires.