โ† All CLC Flashcard Decks

Technology & Digital Tools Flashcards

7 cards from real CLC practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Technology & Digital Tools flashcards as text
  1. Which feature of a Laboratory Information System (LIS) ensures that a test result cannot be released without a supervisory review when a critical value is flagged?

    Answer: Autoverification hold

    An autoverification hold suspends result release and routes critical flags to a supervisor or pathologist before sign-out.

  2. A laboratory is implementing bidirectional interfaces between analyzers and the LIS. What is the primary benefit over a unidirectional interface?

    Answer: Automatic download of worklists to the analyzer and upload of results to the LIS

    Bidirectional interfaces allow both worklist/order downloads to the instrument and automatic result uploads back to the LIS, reducing manual entry errors.

  3. In laboratory informatics, what does the acronym ASTM E1381 standard govern?

    Answer: Low-level protocol for serial communication between analyzers and computers

    ASTM E1381 defines the low-level protocol (physical/data-link layer) for serial communication between clinical instruments and computer systems.

  4. A consultant recommends middleware software between analyzers and the LIS. What primary function does middleware serve in this architecture?

    Answer: Aggregating, processing, and routing data from multiple instruments before it reaches the LIS

    Middleware acts as an intelligent data broker that can apply rules, aggregate multi-instrument data, and route results to the LIS or other systems.

  5. Which cybersecurity framework is most commonly recommended for clinical laboratory IT risk assessments in US healthcare settings?

    Answer: NIST Cybersecurity Framework (CSF)

    The NIST Cybersecurity Framework is widely adopted in US healthcare and aligns with HIPAA Security Rule requirements for risk management.

  6. A laboratory consultant is evaluating a cloud-based LIMS. Which data protection requirement is MOST critical to verify before contract signing?

    Answer: Business Associate Agreement (BAA) execution and HIPAA-compliant data handling

    A signed BAA is legally required under HIPAA when a cloud vendor handles protected health information on behalf of a covered entity.

  7. Delta checks in a LIS compare a patient's current result to a previous result. What is the primary purpose of this function?

    Answer: Detecting specimen identification or transcription errors by flagging physiologically implausible changes

    Delta checks identify results that differ from a patient's prior value beyond a physiologically possible range, helping catch mislabeling or wrong-patient errors.