โ† All CIT Flashcard Decks

Implant Design & Fabrication Flashcards

7 cards from real CIT practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Implant Design & Fabrication flashcards as text
  1. The 'critical healing zone' concept in implant design refers to which anatomical region and its associated biological events?

    Answer: The coronal 2-3mm of crestal bone where biological width establishes

    The coronal crestal bone region is the 'critical healing zone' where biological width establishment determines long-term crestal bone stability.

  2. A bone-level implant placed at the crestal bone with a 4.1mm platform requires an abutment with which emergence profile consideration?

    Answer: Narrow emergence that gradually widens to the crown diameter

    A sub-crestal or crestal bone-level implant requires a gradually widening emergence profile to support peri-implant soft tissue architecture and mimic natural tooth anatomy.

  3. When selecting implant diameter for a mandibular first molar site with adequate bone width, which dimension is most commonly recommended?

    Answer: 4.5-5.0mm wide diameter

    Wide-diameter implants (4.5-5.0mm) are preferred for mandibular molar sites to better replicate the wider root footprint and distribute occlusal forces.

  4. In laser surface modification of titanium implants (SLActive/Laser-Lok), what is the primary mechanism for enhanced soft tissue integration?

    Answer: Parallel circumferential microgrooves that orient connective tissue fibers perpendicularly

    Laser-Lok microgrooves create a physical template that guides connective tissue fiber orientation perpendicular to the implant surface, creating a functional soft tissue attachment.

  5. A 'morse taper' internal connection in an implant system refers to which design characteristic?

    Answer: A conical friction-fit connection with a taper of 5-8 degrees

    Morse taper connections use a precise conical fit (5-8ยฐ) creating a cold-weld friction seal that minimizes micromovement and the implant-abutment microgap.

  6. Which factor most critically determines the minimum required bone height above the inferior alveolar nerve (IAN) when placing a standard 10mm implant?

    Answer: A minimum 2mm safety margin below the implant apex

    A minimum 2mm safety margin between the implant apex and the IAN canal is the standard to prevent nerve injury from drilling or implant pressure.

  7. The 'prosthetic table' concept in wide-platform implants is designed to:

    Answer: Provide a broader implant-crown junction to reduce cantilever stress on the abutment screw

    A wider prosthetic table (platform) on broad-diameter implants reduces the lever arm and bending stress on the abutment screw, improving long-term mechanical reliability.

Implant Design & Fabrication Flashcards โ€” CIT Study Cards with Answers