โ† All CIT Flashcard Decks

CIT Prosthetic Components & Restoration Flashcards

7 cards from real CIT practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 CIT Prosthetic Components & Restoration flashcards as text
  1. Which material is most commonly used for provisional implant-supported restorations due to its ease of modification and repairability?

    Answer: PMMA (polymethylmethacrylate)

    PMMA is the preferred provisional material because it can be easily added to, trimmed, and polished chairside, allowing iterative refinement of tissue contours and occlusion.

  2. In implant prosthodontics, what term describes the misfit at the implant-abutment interface that can lead to microleakage and bone loss?

    Answer: Microgap

    A microgap at the implant-abutment interface allows bacterial colonization and micromovement, contributing to marginal bone loss and peri-implantitis.

  3. A screw-access channel in a screw-retained crown is typically sealed with which material after torquing the prosthetic screw?

    Answer: PTFE (Teflon) tape followed by composite resin

    PTFE tape is placed over the screw head to protect it, and then composite resin seals the access channel, allowing future retrievability by removing the composite.

  4. Which occlusal scheme is generally recommended for implant-supported full-arch fixed prostheses to minimize lateral forces on implants?

    Answer: Bilateral balanced occlusion

    Bilateral balanced occlusion distributes lateral forces evenly across all implants during excursive movements, reducing the risk of overloading individual implants or components.

  5. What is the function of an anti-rotation feature on an implant abutment connection?

    Answer: To prevent the abutment from rotating independently of the implant body

    Anti-rotation features such as hex, octagon, or spline connections physically lock the abutment to the implant to prevent rotational movement, which is essential for single-unit restorations.

  6. When evaluating the fit of an implant framework at try-in, which radiographic finding confirms passive fit?

    Answer: Complete seating of all abutments with no gap visible radiographically at each implant interface

    Radiographic confirmation of passive fit requires that no gap is visible at any implant-abutment junction when each screw is tightened individually, confirming the framework seats completely at every implant.

  7. Which technique is used to verify the accuracy of a master cast by confirming that the implant analogs replicate the exact intraoral implant positions?

    Answer: Verification jig (pick-up index)

    A verification jig is fabricated from the master cast and tried in the patient's mouth; if it seats passively at all implant connections simultaneously, the cast accurately reflects the intraoral implant positions.