← All CIS Flashcard Decks

Regulatory Compliance and Standards Flashcards

6 cards from real CIS practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Regulatory Compliance and Standards flashcards as text
  1. What does the term 'IFU' mean in the context of instrument reprocessing?

    Answer: Instructions for Use — the manufacturer's directions for cleaning, disinfection, and sterilization

    IFU (Instructions for Use) are mandatory manufacturer-provided documents that specify validated methods for reprocessing each device; following the IFU is required by AAMI, TJC, and the FDA.

  2. A facility reprocesses a single-use device (SUD) against the manufacturer's labeling. Who then bears regulatory responsibility for that device?

    Answer: The reprocessing facility becomes the manufacturer and must comply with FDA device regulations

    Under FDA policy, when a facility reprocesses a SUD, it becomes the legal manufacturer and must comply with FDA's 21 CFR 820 quality system regulations for that device.

  3. Which AAMI standard specifically addresses high-level disinfection and liquid chemical sterilization processes?

    Answer: ANSI/AAMI ST58

    ANSI/AAMI ST58 provides guidance on chemical sterilization and high-level disinfection in health care facilities, covering glutaraldehyde, OPA, peracetic acid, and other agents.

  4. What does the Spaulding Classification System categorize?

    Answer: Medical devices by the level of disinfection or sterilization required based on their risk of infection transmission

    The Spaulding Classification System divides medical devices into Critical, Semi-critical, and Non-critical categories, each requiring a corresponding level of reprocessing to prevent infection.

  5. According to OSHA, which PPE is REQUIRED when handling contaminated instruments in the decontamination area?

    Answer: Heavy-duty gloves, fluid-resistant gown, face shield or mask and eye protection

    OSHA's Bloodborne Pathogens Standard requires appropriate PPE including puncture-resistant gloves, fluid-resistant gown, and face/eye protection when handling contaminated instruments.

  6. What is the primary reason sterilization records must be maintained for a minimum period as required by regulation?

    Answer: To support traceability and recall investigations if a sterilization failure is identified

    Sterilization records enable traceability — if a sterilizer malfunction is discovered, records allow identification of all affected loads and patients who received instruments from those loads.