โ† All CFP Flashcard Decks

Safety Standards & Compliance Flashcards

7 cards from real CFP practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Safety Standards & Compliance flashcards as text
  1. Which building code organization publishes the International Residential Code (IRC), which many jurisdictions use for residential fence height and setback standards?

    Answer: International Code Council (ICC)

    The International Code Council (ICC) publishes the IRC, which is widely adopted by local jurisdictions as the basis for residential fence and barrier regulations.

  2. Pool barrier fences in the US must comply with which ASTM standard for entrapment and climbability requirements?

    Answer: ASTM F2200

    ASTM F2200 specifies the performance requirements for pool barrier fences, including opening size, height, and climbability to prevent child drowning.

  3. When a fence post hole is left open overnight on a job site, OSHA requires it to be:

    Answer: Covered with a material able to support 200 lbs and secured against displacement

    OSHA 29 CFR 1926.502 requires that floor/ground openings be covered with materials strong enough to support at least twice the maximum intended load and secured to prevent accidental removal.

  4. The OSHA Heat Illness Prevention standard requires employers in outdoor construction to provide water to workers at what minimum rate?

    Answer: 1 quart per hour

    OSHA recommends and Cal/OSHA mandates providing at least 1 quart (32 oz) of water per hour to outdoor workers in hot conditions to prevent heat illness.

  5. A fence contractor's employee is injured on the job. Under OSHA recordkeeping rules, a work-related injury requiring medical treatment beyond first aid must be recorded on which form?

    Answer: OSHA Form 300

    OSHA Form 300 (Log of Work-Related Injuries and Illnesses) is required to record all work-related injuries and illnesses that meet the recordable criteria.

  6. When handling pressure-treated lumber containing chromated copper arsenate (CCA), which safety precaution is critical?

    Answer: Wear gloves and a dust mask; never burn scraps

    CCA-treated wood contains arsenic compounds; burning releases toxic fumes, and dust inhalation during cutting requires respiratory protection and gloves.

  7. A fence installation crew is setting posts near overhead power lines. OSHA requires maintaining a minimum clearance of how many feet from lines rated 50 kV or below?

    Answer: 10 feet

    OSHA 29 CFR 1926.1408 requires a minimum 10-foot clearance from overhead power lines rated up to 50 kV for unqualified workers and equipment.