  1. In a high-rise building, elevator machine rooms are often pressurized during a fire event. What is the primary reason for this?

    Answer: To prevent smoke infiltration into the machine room and hoistway

    Pressurizing machine rooms and hoistways prevents smoke from migrating into these spaces, protecting equipment and maintaining safe elevator operation.

  2. A certified elevator technician discovers that the Phase I key switch is stuck in the 'ON' position and cannot be returned to 'OFF.' What is the correct immediate action?

    Answer: Tag the switch out of service and notify the building owner and authority having jurisdiction

    A malfunctioning Phase I key switch must be tagged out of service and reported to the building owner and AHJ since it is a life-safety component.

  3. Under ASME A17.1, what minimum illumination is required inside an elevator car during firefighters' Phase II service?

    Answer: Emergency lighting providing at least 5 foot-candles

    ASME A17.1 requires emergency in-car lighting of at least 5 foot-candles during firefighters' service so occupants and firefighters can operate safely.

  4. A firefighter using Phase II service presses a floor button but the doors do not close. What most likely caused this?

    Answer: The door open button is being held simultaneously

    In Phase II, doors will not close if the door open button is being held; releasing it allows the close button to function.

  5. When a building fire alarm system activates but the fire is confirmed to be in the basement, elevators should recall to:

    Answer: The alternate designated level (one floor above main)

    When the main designated level is at or adjacent to the fire floor, elevators recall to the alternate designated level, typically one floor above the main.

  6. What does the term 'non-stop' mean in the context of Phase I elevator recall?

    Answer: The elevator does not respond to hall calls or car calls en route to the designated level

    Non-stop recall means the elevator bypasses all registered hall and car calls and travels directly to the designated level without stopping.

  7. Which of the following is NOT a required feature of the in-car Phase II firefighters' service switch?

    Answer: It must automatically call for help when activated

    Phase II switches must be key-operated with ON/OFF positions in the car operating panel, but they do not have an automatic distress call function.