Certified Elevator Technician (CET) — Questions and Answers
Question 1: What is the PRIMARY purpose of continuing education requirements in Hydraulic Elevator Systems for CET professionals?
- Earning additional credentials for career advancement
- Maintaining current knowledge and competency as the field evolves (Correct answer)
- Networking with other professionals in the field
- Fulfilling mandatory regulatory requirements only
Correct answer: Maintaining current knowledge and competency as the field evolves
Continuing education in Hydraulic Elevator Systems ensures professionals maintain current knowledge and skills as standards, technologies, and best practices evolve in the Certified Elevator Technician field.
Question 2: Which factor most directly determines the sheave groove diameter's effect on rope fatigue life?
- Groove depth
- The ratio of sheave pitch diameter to rope diameter (D/d ratio) (Correct answer)
- Groove hardness
- Number of grooves on the sheave
Correct answer: The ratio of sheave pitch diameter to rope diameter (D/d ratio)
The D/d ratio determines the bending radius the rope experiences each cycle; a higher D/d ratio means less bending stress and longer rope fatigue life.
Question 3: In a variable-frequency drive (VFD) controlled elevator, what determines the motor's rotational speed?
- The output frequency supplied by the VFD (Correct answer)
- The DC bus voltage level
- The number of motor poles only
- The gate signal to the IGBT modules
Correct answer: The output frequency supplied by the VFD
Motor speed in a VFD system is directly proportional to the output frequency, allowing smooth acceleration and deceleration profiles.
Question 4: In an elevator control circuit, what does a 'slowdown' switch typically do?
- Switches the motor from high to low speed winding
- Engages the emergency brake system
- Signals the controller to begin deceleration before reaching a landing (Correct answer)
- Stops the car at the terminal floor immediately
Correct answer: Signals the controller to begin deceleration before reaching a landing
A slowdown switch triggers the controller to initiate deceleration so the car arrives at a landing at proper leveling speed.
Question 5: In elevator electrical work, what does 'megger testing' verify?
- Insulation resistance of wiring, motors, and cables (Correct answer)
- Correct phase sequence of the main power supply
- Motor shaft alignment and bearing condition
- Continuity of the safety circuit chain
Correct answer: Insulation resistance of wiring, motors, and cables
A megohmmeter (megger) applies high DC voltage to measure insulation resistance, verifying that insulation has not degraded due to moisture, heat, or age.
Question 6: Which type of motor is commonly used in modern traction elevator systems?
- AC induction motor
- AC gearless permanent magnet motor (Correct answer)
- DC brushed motor
- Stepper motor
Correct answer: AC gearless permanent magnet motor
AC gearless permanent magnet motors are widely used for their energy efficiency and smooth operation.
Question 7: What must be done to an elevator after a governor and safety test is completed successfully?
- Install new safety jaws and retest
- Submit the elevator for re-certification immediately
- Replace all governor rope segments
- Inspect and reset the governor, reset safeties, test normal operation before returning to service (Correct answer)
Correct answer: Inspect and reset the governor, reset safeties, test normal operation before returning to service
After a safety test, the governor must be reset, safety devices inspected and reset, and normal operation verified before the elevator returns to passenger service.
Question 8: Why is personal protective equipment (PPE) important for elevator technicians?
- Is optional per site supervisor
- Reduces risk of workplace injury (Correct answer)
- Improves technician appearance
- Speeds up installation
Correct answer: Reduces risk of workplace injury
PPE such as gloves, helmets, and safety harnesses reduce the risk of injury from falls, electrical contact, or falling objects.
Question 9: When replacing conductors in an existing elevator installation, the new conductors must:
- Be installed using the original wiring methods even if those methods are now outdated
- Meet or exceed current applicable code requirements regardless of the original installation date (Correct answer)
- Be the same insulation color as the original wiring being replaced
- Match the original manufacturer's wire type and part number exactly
Correct answer: Meet or exceed current applicable code requirements regardless of the original installation date
Replacement conductors must comply with current code requirements; the original installation date does not allow grandfathering of substandard replacement materials or methods.
Question 10: In a duplex elevator group, what does 'dispatching logic' in the group controller determine?
- Which car responds to a hall call based on position, direction, and load (Correct answer)
- The motor acceleration rate for each individual car
- The door open time for each landing
- The leveling sensitivity at each floor
Correct answer: Which car responds to a hall call based on position, direction, and load
Dispatching logic assigns hall calls to the most efficient car based on real-time factors such as car position, travel direction, and passenger load.
Question 11: What documentation must an elevator contractor provide to the AHJ upon completion of a modernization?
- A list of replaced parts with their costs
- A customer satisfaction survey
- A permit, as-built wiring diagrams, and a certificate of compliance or inspection (Correct answer)
- Only a verbal confirmation that work is complete
Correct answer: A permit, as-built wiring diagrams, and a certificate of compliance or inspection
ASME A17.1 and most jurisdictions require updated as-built drawings, a closed permit, and an inspection certificate before returning the elevator to normal service.
Question 12: How does counterweight percentage of balance affect traction elevator energy consumption?
- Counterweight balance has no effect on energy consumption
- A counterweight balanced at 40–50% of rated load minimizes energy use by offsetting load in both directions (Correct answer)
- A heavier counterweight always saves energy going up
- Higher counterweight balance always reduces energy use regardless of traffic
Correct answer: A counterweight balanced at 40–50% of rated load minimizes energy use by offsetting load in both directions
Balancing at 40–50% of rated capacity means the motor does minimal work for light up-trips and light down-trips, optimizing energy across typical traffic patterns.
Question 13: Which ASME A17.1 rule governs the minimum factor of safety for elevator hoist ropes?
- 10.5 (Correct answer)
- 12.0
- 7.1
- 8.5
Correct answer: 10.5
ASME A17.1 requires a minimum factor of safety of 10.5 for steel wire hoist ropes based on rated load and speed.
Question 14: How often must routine safety inspections typically be conducted on commercial elevators?
- Only before installation
- When requested by building owner
- Every 5 years
- Annually (Correct answer)
Correct answer: Annually
Most jurisdictions require annual safety inspections to ensure continued safe operation and compliance with code requirements.
Question 15: When an existing hydraulic elevator's muffler is replaced during modernization, what is the main reason for this replacement?
- To increase pump output pressure
- To reduce hydraulic fluid pulsation noise transmitted through the piping and structure (Correct answer)
- To allow a larger diameter pipe to be used
- To eliminate the need for a pressure relief valve
Correct answer: To reduce hydraulic fluid pulsation noise transmitted through the piping and structure
Mufflers dampen pressure pulsations generated by the pump, reducing vibration and noise transmitted into the building structure and occupant spaces.
Question 16: A technician finds the car is consistently 1 inch below floor level at all landings when heavily loaded. The MOST likely cause on a traction elevator is:
- A misadjusted door cam roller
- Rope stretch due to increased load (Correct answer)
- Worn car guide shoes causing car tilt
- A faulty floor selector magnet
Correct answer: Rope stretch due to increased load
Under heavy load, hoist ropes stretch slightly beyond their normal length, causing the car to stop lower than the leveling position; re-leveling or rope compensation is required.
Question 17: What is the role of the door dwell time setting on an automatic elevator door operator?
- Limits how long the door will attempt to close before reversing
- Determines the motor acceleration rate during opening
- Sets the maximum door closing speed
- Controls how long the door pauses at the fully open position before closing (Correct answer)
Correct answer: Controls how long the door pauses at the fully open position before closing
Door dwell time is the adjustable period the door remains fully open at a landing, giving passengers adequate time to enter or exit before automatic closing begins.
Question 18: Which type of governor rope is required for use with elevator governors per ASME A17.1?
- Synthetic fiber rope
- Fiber core wire rope
- Independent wire rope core (IWRC) (Correct answer)
- Chain drive linkage
Correct answer: Independent wire rope core (IWRC)
ASME A17.1 requires independent wire rope core (IWRC) governor ropes for their superior strength and resistance to crushing.
Question 19: When an elevator is used as part of an accessible means of egress per IBC and ADA, what additional equipment is typically required inside the cab?
- Emergency lighting only
- Smoke detectors and sprinkler heads
- Fire-rated cab interior materials
- Two-way communication and standby power (Correct answer)
Correct answer: Two-way communication and standby power
Elevators serving as accessible means of egress must have two-way communication systems and standby power to operate during emergencies.
Question 20: According to ASME A17.1, what must happen if the door reopening device fails on a power-operated door?
- The door must remain open until repaired
- The door must still be able to close at reduced speed (Correct answer)
- The door may close at normal speed with a warning buzzer
- The elevator must be taken out of service immediately
Correct answer: The door must still be able to close at reduced speed
If the reopening device (such as a safety edge or light curtain) fails, the door must still be capable of closing but must do so at reduced kinetic energy.
Question 21: Which standard of practice is MOST important for ensuring quality in Accessibility & ADA Compliance?
- Minimizing documentation to focus on practical work
- Following evidence-based protocols while adapting to specific circumstances (Correct answer)
- Using the most advanced technology available regardless of need
- Strictly adhering to the same procedure in every situation
Correct answer: Following evidence-based protocols while adapting to specific circumstances
Evidence-based protocols provide a foundation of proven practices, but effective Certified Elevator Technician professionals must also adapt their approach based on specific circumstances and individual case needs within Accessibility & ADA Compliance.
Question 22: Per NEC Article 620, which wiring method is approved for use inside elevator hoistways?
- Non-metallic sheathed cable (NM-B) stapled to hoistway concrete
- Rigid metal conduit (RMC), intermediate metal conduit (IMC), or electrical metallic tubing (EMT) (Correct answer)
- Armored cable (AC) stapled at 4-foot maximum intervals
- Open wiring on porcelain insulators at 4-foot intervals
Correct answer: Rigid metal conduit (RMC), intermediate metal conduit (IMC), or electrical metallic tubing (EMT)
NEC Article 620 requires conductors in hoistways to be installed in metal raceways such as RMC, IMC, or EMT to protect wiring from the mechanical hazards present in the hoistway environment.
Question 23: How does risk management apply to daily practice in Fire Service & Emergency Operations for Certified Elevator Technician professionals?
- By avoiding high-risk situations entirely
- Through proactive identification of potential hazards and implementation of preventive measures (Correct answer)
- Only through responding to incidents after they occur
- Through annual safety audits exclusively
Correct answer: Through proactive identification of potential hazards and implementation of preventive measures
Effective risk management in Fire Service & Emergency Operations requires proactive hazard identification and preventive measures, not just reactive responses. This approach reduces incidents, improves outcomes, and protects both professionals and clients.
Question 24: What is the purpose of the inner and outer decking on an escalator balustrade?
- Houses the step-chain lubrication reservoir
- Covers the internal components and provides a smooth surface adjacent to the steps (Correct answer)
- Provides structural support for the truss
- Guides the handrail return path
Correct answer: Covers the internal components and provides a smooth surface adjacent to the steps
Balustrade decking panels enclose the internal step-chain and guide mechanisms while presenting a smooth surface that reduces entrapment risk at the step-skirt interface.
Question 25: What documentation practice is considered essential in Escalator & Moving Walk Systems within the Certified Elevator Technician field?
- Using shorthand notes that can be expanded later if needed
- Only documenting unusual events or complications
- Recording actions, observations, and outcomes in real-time or as close to the event as possible (Correct answer)
- Completing all documentation at the end of the workday
Correct answer: Recording actions, observations, and outcomes in real-time or as close to the event as possible
Real-time or near-real-time documentation in Escalator & Moving Walk Systems ensures accuracy, provides a contemporaneous record, and is considered the gold standard for professional accountability and legal defensibility.
Question 26: A property owner wants to increase an elevator's speed from 100 FPM to 200 FPM during a modernization. Which component is most likely to require replacement due to this speed increase?
- The hall lanterns
- The governor (Correct answer)
- The machine room ventilation
- The car flooring
Correct answer: The governor
The governor must be replaced because its tripping speed is calibrated for the original contract speed, not the new higher speed.
Question 27: Under ADA and ASME A17.1, the door dwell time (time doors remain fully open at a landing) must be a minimum of how many seconds for an accessible elevator?
- 3 seconds (Correct answer)
- 5 seconds
- 10 seconds
- 2 seconds
Correct answer: 3 seconds
ADA Section 407.3.4 requires doors to remain fully open for a minimum of 3 seconds to allow wheelchair users sufficient time to enter or exit.
Question 28: What type of hydraulic fluid is recommended for environmentally sensitive installations?
- Phosphate ester fire-resistant fluid
- Petroleum-based ISO VG 46 fluid
- Water-glycol hydraulic fluid
- Biodegradable vegetable-based or synthetic ester fluid (Correct answer)
Correct answer: Biodegradable vegetable-based or synthetic ester fluid
Biodegradable vegetable-based or synthetic ester fluids are used in environmentally sensitive areas because they break down naturally if spilled.
Question 29: Which ASME A17.1 rule requires that escalator handrails be checked to ensure they move in the same direction and at approximately the same speed as the steps?
- Rule 8.6.1.1 (Correct answer)
- Rule 6.2.4.2
- Rule 6.1.3
- Rule 6.1.6.1
Correct answer: Rule 8.6.1.1
ASME A17.1 Rule 8.6.1.1 (periodic inspections for escalators) includes verifying handrail speed relative to step speed to prevent passenger falls.
Question 30: Conductors from different systems (such as lighting, power, and signal circuits) installed in the same elevator wireway must:
- Always be the same AWG gauge to prevent voltage differences
- Be separated by a metal barrier or otherwise comply with NEC requirements for system separation (Correct answer)
- Have identical insulation color coding throughout the installation
- All be grounded to a single common point within the wireway
Correct answer: Be separated by a metal barrier or otherwise comply with NEC requirements for system separation
NEC Article 620 and ASME A17.1 require separation of conductors from different systems to prevent electrical interference, cross-talk, and safety hazards from mixing incompatible circuit types.
Question 31: What is the MOST common cause of hydraulic elevator cylinder corrosion on underground installations?
- Excessive pump pressure
- Electrolytic corrosion from stray electrical currents in the soil (Correct answer)
- Contaminated hydraulic fluid inside the cylinder
- High hydraulic fluid temperature
Correct answer: Electrolytic corrosion from stray electrical currents in the soil
Underground steel cylinders are susceptible to electrolytic (galvanic) corrosion caused by stray ground currents passing through the soil.
Question 32: What type of lighting is required in an elevator machine room?
- Permanent artificial illumination of at least 19 foot-candles (Correct answer)
- Natural lighting with a window
- Emergency lighting only
- Portable task lighting only
Correct answer: Permanent artificial illumination of at least 19 foot-candles
ASME A17.1 requires permanent artificial lighting providing a minimum of 19 foot-candles (200 lux) at the floor level in machine rooms.
Question 33: What is the PRIMARY purpose of continuing education requirements in Fire Service & Emergency Operations for CET professionals?
- Earning additional credentials for career advancement
- Networking with other professionals in the field
- Maintaining current knowledge and competency as the field evolves (Correct answer)
- Fulfilling mandatory regulatory requirements only
Correct answer: Maintaining current knowledge and competency as the field evolves
Continuing education in Fire Service & Emergency Operations ensures professionals maintain current knowledge and skills as standards, technologies, and best practices evolve in the Certified Elevator Technician field.
Question 34: What effect does cold ambient temperature have on hydraulic elevator start-up performance?
- It causes the relief valve to open at a lower pressure
- It increases oil viscosity, potentially causing sluggish operation and poor leveling (Correct answer)
- It has no significant effect on performance
- It decreases oil viscosity, causing faster car acceleration
Correct answer: It increases oil viscosity, potentially causing sluggish operation and poor leveling
Cold temperatures increase oil viscosity, making it flow more slowly through valves and restricting flow, which results in sluggish starts and poor leveling until the fluid warms up.
Question 35: What documentation practice is considered essential in Door Operators & Interlocks within the Certified Elevator Technician field?
- Only documenting unusual events or complications
- Completing all documentation at the end of the workday
- Using shorthand notes that can be expanded later if needed
- Recording actions, observations, and outcomes in real-time or as close to the event as possible (Correct answer)
Correct answer: Recording actions, observations, and outcomes in real-time or as close to the event as possible
Real-time or near-real-time documentation in Door Operators & Interlocks ensures accuracy, provides a contemporaneous record, and is considered the gold standard for professional accountability and legal defensibility.
Question 36: When an elevator is taken out of service for maintenance, ASME A17.1 requires that the car doors be locked or the car be parked:
- At the top floor with doors open
- At the bottom landing with doors closed (Correct answer)
- At any landing with a barricade
- At the main landing with doors open
Correct answer: At the bottom landing with doors closed
When taken out of service, the elevator car should be parked at the bottom terminal landing with the car and hoistway doors closed and locked to prevent access.
Question 37: How must traveling cables be attached at the car and at the overhead support point?
- With strain relief so that conductors are not subjected to tensile stress at terminations (Correct answer)
- With cable ties spaced every 12 inches along the cable run
- Welded directly to the car sling frame for a permanent connection
- With spring-loaded connectors that allow free movement in all directions
Correct answer: With strain relief so that conductors are not subjected to tensile stress at terminations
Strain relief prevents mechanical tension from being transferred to the electrical connections, protecting conductors and terminals from fatigue failures caused by the cable's weight and motion.
Question 38: An elevator technician is testing Phase I recall. After activating the lobby key switch to 'RECALL,' one car continues to answer hall calls. What is the most likely cause?
- The Phase I wiring to that car's controller is open or disconnected (Correct answer)
- The car's doors are in the open position
- The car is on independent service
- The building fire alarm panel has overridden Phase I
Correct answer: The Phase I wiring to that car's controller is open or disconnected
If a car continues normal operation during Phase I recall, the most likely cause is a wiring fault preventing the recall signal from reaching that car's controller.
Question 39: On a high-speed door operator, what is the primary function of the door nudging feature?
- Reverses the door if resistance exceeds a set threshold
- Prevents the door from closing when passengers are detected
- Sounds an alarm when the door is blocked
- Speeds up door closing when an obstruction is detected for an extended period (Correct answer)
Correct answer: Speeds up door closing when an obstruction is detected for an extended period
Door nudging reduces closing speed and sounds a warning signal to clear obstructions that have held the door open beyond the preset time.
Question 40: Per ASME A17.1, what is the maximum allowable pit depth for a standard traction elevator without requiring an access ladder?
- 30 inches
- 24 inches
- 60 inches
- 48 inches (Correct answer)
Correct answer: 48 inches
ASME A17.1 requires a fixed metal ladder in pits deeper than 48 inches to allow safe access for maintenance personnel.
Question 41: During a traction elevator modernization, the existing wire rope is found to have broken wires within the allowable limit but shows significant corrosion. What is the correct action?
- Apply additional lubrication and re-inspect in 30 days
- Replace the ropes because corrosion is an independent disqualifying condition (Correct answer)
- Continue using the rope until the broken wire limit is exceeded
- Document the corrosion and proceed with modernization
Correct answer: Replace the ropes because corrosion is an independent disqualifying condition
Corrosion is an independent condition requiring rope replacement, regardless of broken wire count, because it compromises tensile strength unpredictably.
Question 42: What safety component cuts off power during an elevator malfunction?
- Surge protector
- Voltage stabilizer
- Contactor
- Circuit breaker (Correct answer)
Correct answer: Circuit breaker
A circuit breaker or main disconnect switch is designed to interrupt power during overload or faults to protect the system.
Question 43: Which code primarily governs elevator safety standards in North America?
- OSHA 1910
- NEC 2020
- ASME A17.1/CSA B44 (Correct answer)
- NFPA 70E
Correct answer: ASME A17.1/CSA B44
The ASME A17.1/CSA B44 Safety Code for Elevators is the key regulatory standard used throughout North America.
Question 44: What is the purpose of 'compensating ropes' or 'compensating chains' in a tall-rise traction elevator?
- Compensate for the weight imbalance caused by hoist rope weight shifting as the car travels (Correct answer)
- Provide a backup rope system in case primary ropes fail
- Connect the car safety to the governor rope
- Limit the travel speed on long rises
Correct answer: Compensate for the weight imbalance caused by hoist rope weight shifting as the car travels
Compensating ropes or chains loop under the car and counterweight to compensate for the changing weight of hoist ropes as the car moves up and down in high-rise applications.
Question 45: In a microprocessor-based elevator control system, what is a 'serial link' typically used for?
- Supplying DC power to the motor encoder
- Carrying high-voltage power to the car top junction box
- Providing a dedicated safety circuit path for the door contacts
- Communicating data between the machine room controller and the car operating panel (COP) (Correct answer)
Correct answer: Communicating data between the machine room controller and the car operating panel (COP)
A serial communication link (e.g., CAN bus or RS-485) transmits button calls, status data, and commands between the controller and the COP, reducing the number of traveling cables needed.
Question 46: What is the function of a 'door reversal device' in the elevator door control circuit?
- Acts as a mechanical stop at the fully open position
- Powers the door operator from an alternate source if the main supply fails
- Reverses the door motor winding connections to enable reopening
- Detects an obstruction and signals the door operator to reverse from closing to opening (Correct answer)
Correct answer: Detects an obstruction and signals the door operator to reverse from closing to opening
The door reversal device (such as a safety edge, light curtain, or pressure sensor) detects an obstruction and immediately commands the door operator to reverse direction and reopen.
Question 47: A traction elevator's guide rails show excessive rust pitting. What is the PRIMARY concern with this condition?
- Electrical grounding issues
- Lubricant contamination of the pit
- Increased guide shoe wear
- Impaired safety engagement and car ride quality (Correct answer)
Correct answer: Impaired safety engagement and car ride quality
Pitted rails can prevent the safety device from gripping uniformly, compromising emergency stopping performance and causing rough car movement.
Question 48: What is the effect of connecting a 230V elevator control transformer primary to a 208V supply?
- The secondary output voltage will be proportionally lower than design, potentially causing control malfunctions (Correct answer)
- The transformer will overheat and fail immediately
- The secondary voltage will remain at the rated value due to voltage regulation
- There will be no effect because both voltages are within 10% tolerance
Correct answer: The secondary output voltage will be proportionally lower than design, potentially causing control malfunctions
A lower-than-rated primary voltage produces a proportionally lower secondary voltage, which can cause contactors to drop out or PLC inputs to fall below their minimum threshold.
Question 49: What documentation practice is considered essential in Accessibility & ADA Compliance within the Certified Elevator Technician field?
- Only documenting unusual events or complications
- Recording actions, observations, and outcomes in real-time or as close to the event as possible (Correct answer)
- Completing all documentation at the end of the workday
- Using shorthand notes that can be expanded later if needed
Correct answer: Recording actions, observations, and outcomes in real-time or as close to the event as possible
Real-time or near-real-time documentation in Accessibility & ADA Compliance ensures accuracy, provides a contemporaneous record, and is considered the gold standard for professional accountability and legal defensibility.
Question 50: What is the purpose of sealing or sealing provisions on a governor after adjustment?
- To prevent unauthorized adjustment of the trip speed setting (Correct answer)
- To lubricate the flyweight bearings
- To protect the jaws from corrosion
- To secure the governor rope end fittings
Correct answer: To prevent unauthorized adjustment of the trip speed setting
Governors are sealed after calibration to ensure trip speed settings cannot be altered without evidence of tampering, maintaining safety integrity.
Question 51: What is the primary function of a phase-loss relay in a three-phase elevator motor circuit?
- Balance the load across all three phases
- Disconnect the motor if one phase is lost (Correct answer)
- Regulate motor speed during acceleration
- Provide overcurrent protection for the motor
Correct answer: Disconnect the motor if one phase is lost
A phase-loss relay monitors all three phases and disconnects the motor if any single phase is lost, preventing single-phasing damage.
Question 52: During a door interlock test, a technician bypasses the hoistway door interlock and the car moves. This result indicates:
- The door operator speed is too high and must be adjusted
- The interlock circuit is correctly wired in series
- The retiring cam needs realignment
- The interlock is NOT in the safety circuit and must be corrected (Correct answer)
Correct answer: The interlock is NOT in the safety circuit and must be corrected
If bypassing the interlock allows car movement, the interlock is not properly in series with the safety circuit, which is a code violation requiring immediate correction.
Question 53: Which component in a traction elevator system prevents the car from exceeding its rated speed?
- Governor (Correct answer)
- Buffer
- Safety device
- Brake drum
Correct answer: Governor
The governor monitors car speed and triggers the safety device if the car exceeds the overspeed threshold defined by ASME A17.1.
Question 54: The traveling cable loop transition point (where the cable changes from hanging down to running upward) should ideally be located:
- At the machine room floor level for easy inspection access
- At the lowest landing to minimize cable stress during high-speed travel
- At the top of the hoistway to reduce the unsupported length of cable
- Near the midpoint of the car's travel range to minimize cable movement and mechanical stress (Correct answer)
Correct answer: Near the midpoint of the car's travel range to minimize cable movement and mechanical stress
Positioning the loop transition near mid-travel minimizes the total range of cable movement and reduces cumulative mechanical stress on conductors over the life of the installation.
Question 55: A firefighter on Phase II service wants to travel from floor 5 to floor 12. After pressing the '12' button and pressing door close, the doors do not close. What should the technician check first during the post-incident inspection?
- Whether the Phase I key switch was still in the 'ON' position
- Whether the door reopening device (safety edge) was obstructed or defective (Correct answer)
- Whether the car was overloaded beyond its rated capacity
- Whether the machine room ventilation fan had failed
Correct answer: Whether the door reopening device (safety edge) was obstructed or defective
A defective or obstructed door reopening device (safety edge or light curtain) can prevent door closing during Phase II service.
Question 56: On a hydraulic elevator, the overspeed valve (rupture valve) is designed to close when:
- The pump motor overheats
- The car reaches the top floor
- Oil flow rate exceeds a preset limit during descent (Correct answer)
- The oil temperature drops below minimum
Correct answer: Oil flow rate exceeds a preset limit during descent
The rupture valve closes automatically when downward oil flow exceeds the rated descent speed flow rate, stopping uncontrolled descent.
Question 57: What is the maximum time delay allowed between the arrival of an elevator at a landing and the opening of the doors, per ASME A17.1 accessibility provisions?
- The doors must begin opening at landing (Correct answer)
- 3 seconds after arrival
- 5 seconds after arrival
- 2 seconds after arrival
Correct answer: The doors must begin opening at landing
ASME A17.1 requires doors to begin opening at landing without delay; any hold-open dwell time starts after the doors have opened.
Question 58: A building owner asks why some elevators have TWO designated recall floors (main and alternate). Which scenario makes the alternate level necessary?
- Buildings with more than 10 elevators always need an alternate level
- Buildings over 75 feet must designate two recall floors per IBC
- When smoke is detected at the main designated level lobby, elevators divert to the alternate (Correct answer)
- The alternate level is for freight elevators only
Correct answer: When smoke is detected at the main designated level lobby, elevators divert to the alternate
The alternate designated level is required specifically for situations where smoke is detected in the lobby of the main designated level, preventing recall into a hazardous environment.
Question 59: Traveling cables used in elevator installations must be:
- Listed specifically for elevator use and capable of withstanding repeated flexing (Correct answer)
- Standard THHN building wire bundled in flexible metallic conduit
- Any UL-listed wire of sufficient gauge for the connected load
- Solid conductor wire rated at 600V minimum per NEC
Correct answer: Listed specifically for elevator use and capable of withstanding repeated flexing
Elevator traveling cables must be specifically listed for this application due to the unique demands of continuous flexing, torsion, and hoistway environmental conditions that standard wire cannot withstand.
Question 60: What is the maximum permitted gap between the escalator step riser and the step tread of the following step in the incline section?
- 1/4 inch
- 3/8 inch
- 1/2 inch
- 3/16 inch (Correct answer)
Correct answer: 3/16 inch
ASME A17.1 limits the gap between step components to 3/16 inch (4.76 mm) to prevent entrapment of small feet or footwear.
Question 61: What does 'harmonic distortion' from an elevator VFD affect in a building electrical system?
- The VFD's internal DC bus only
- Only the elevator motor windings
- Only lighting circuits on the same phase
- Other equipment connected to the same electrical distribution system (Correct answer)
Correct answer: Other equipment connected to the same electrical distribution system
VFDs generate harmonic currents that travel through the building's electrical distribution system and can cause overheating, nuisance tripping, and interference with sensitive equipment throughout the building.
Question 62: Per NEC 250.119, which color identifies the equipment grounding conductor in elevator wiring?
- White or gray, consistent with neutral conductor identification
- Green, green with yellow stripe, or bare copper (Correct answer)
- Orange, reserved for ungrounded conductors in high-leg delta systems
- Blue, used universally for grounding in three-phase systems
Correct answer: Green, green with yellow stripe, or bare copper
NEC 250.119 requires equipment grounding conductors to be green, green with yellow stripes, or bare copper — this standard applies uniformly across all NEC applications including elevators.
Question 63: Which ASME A17.1 rule governs the requirement for firefighters' emergency operation (Phase I and Phase II)?
- Rule 3.26.3
- Rule 2.26.1.2
- Rule 2.26.2 (Correct answer)
- Rule 2.27.3
Correct answer: Rule 2.26.2
ASME A17.1 Rule 2.26.2 establishes requirements for firefighters' emergency operation including Phase I recall and Phase II in-car service.
Question 64: Why must counterweight clearances be verified whenever new rope is installed on a traction elevator?
- New rope creates more traction and causes the car to overshoot floors
- New rope stretches during run-in, lowering the counterweight position and reducing pit clearance (Correct answer)
- New rope increases brake wear due to higher tension
- New rope is heavier and may overload the motor
Correct answer: New rope stretches during run-in, lowering the counterweight position and reducing pit clearance
New hoist ropes stretch during initial operation; if not accounted for, the counterweight may descend lower than designed, reducing the required pit buffer clearance.
Question 65: What minimum temperature must be maintained in an elevator machine room to protect electrical and mechanical components?
- 40°F (4°C)
- 60°F (15°C)
- 32°F (0°C)
- 50°F (10°C) (Correct answer)
Correct answer: 50°F (10°C)
ASME A17.1 requires machine room temperatures to be maintained above 50°F (10°C) to protect lubricants, electrical components, and control systems.
Question 66: In Fire Service & Emergency Operations, what is the FIRST step a CET professional should take when encountering a new case or situation?
- Document the situation and wait for further instructions
- Implement an immediate solution based on past experience
- Conduct a comprehensive assessment and gather all relevant information (Correct answer)
- Consult with a supervisor before taking any action
Correct answer: Conduct a comprehensive assessment and gather all relevant information
In Fire Service & Emergency Operations, a thorough initial assessment ensures all relevant factors are identified before deciding on an appropriate course of action. This systematic approach is fundamental to Certified Elevator Technician practice.
Question 67: Which component prevents passengers from inserting objects between the handrail and the balustrade deck at the newel?
- Comb segment
- Deck guard
- Skirt brush
- Handrail entry guard (deflector) (Correct answer)
Correct answer: Handrail entry guard (deflector)
Handrail entry guards are installed where the handrail enters the newel to prevent hands, clothing, or objects from being drawn into the handrail slot.
Question 68: What is the purpose of the pit stop switch on a traction elevator?
- Activates the oil buffer
- Stops the car at the lowest landing
- Resets the safety circuit after overspeed
- De-energizes the elevator for pit maintenance (Correct answer)
Correct answer: De-energizes the elevator for pit maintenance
The pit stop switch is a red emergency stop switch that cuts power to the elevator to allow safe maintenance work inside the pit.
Question 69: Which of the following conditions would cause a 'door open fault' on a microprocessor-based door operator during a closing cycle?
- The door fails to reach the fully closed position within the allotted time (Correct answer)
- The motor current exceeds the rated amperage for more than 5 seconds
- The door closes faster than the programmed high-speed profile
- The light curtain detects a break during the open dwell period
Correct answer: The door fails to reach the fully closed position within the allotted time
A door open fault is triggered when the door fails to complete its travel to the fully closed position within the controller's preset time window.
Question 70: A hydraulic elevator car drifts downward more than 3/8 inch within 5 minutes after arrival. According to ASME A17.1, this indicates:
- Excessive valve leakage that must be corrected before continued operation (Correct answer)
- A pump that is oversized for the application
- An improperly adjusted up-limit switch
- Normal behavior due to thermal contraction of the fluid
Correct answer: Excessive valve leakage that must be corrected before continued operation
ASME A17.1 sets a maximum allowable settlement limit; excessive drift indicates internal valve leakage that must be repaired to maintain safe leveling.
Question 71: Which NFPA standard governs fire safety requirements for escalators and moving walks in buildings?
- NFPA 70
- NFPA 72
- NFPA 13
- NFPA 101 (Correct answer)
Correct answer: NFPA 101
NFPA 101 (Life Safety Code) addresses escalator use as a means of egress and includes fire safety requirements for escalator openings between floors.
Question 72: Under ASME A17.1, which component is required to prevent the elevator car from descending into the pit when workers are present?
- Car safeties
- Pit stop switch
- Car-on-pit-floor mechanical lock (Correct answer)
- Runby limiting device
Correct answer: Car-on-pit-floor mechanical lock
A car-on-pit-floor mechanical lock (pit prop or equivalent) prevents the car from descending onto pit workers during maintenance work in the pit.
Question 73: What is the function of the car top inspection station (CTIS) on an elevator?
- Resets the overspeed governor
- Allows authorized personnel to operate the car at low speed from the car top for maintenance (Correct answer)
- Controls lighting in the hoistway
- Monitors door open/close cycles
Correct answer: Allows authorized personnel to operate the car at low speed from the car top for maintenance
The CTIS provides an inspection control that overrides normal operation, limiting car speed to inspection speed so technicians can safely work on top of the car.
Question 74: The 'Category 5 test' for elevators under ASME A17.1 requires which type of load test?
- No-load test at rated speed
- 125% rated load static test
- Full rated load test with safety device actuation (Correct answer)
- 150% rated load dynamic test
Correct answer: Full rated load test with safety device actuation
A Category 5 test is a full load test that includes actuation of the safety device with the rated load in the car to verify the car safety system can stop and hold the load.
Question 75: How does risk management apply to daily practice in Accessibility & ADA Compliance for Certified Elevator Technician professionals?
- Through proactive identification of potential hazards and implementation of preventive measures (Correct answer)
- By avoiding high-risk situations entirely
- Through annual safety audits exclusively
- Only through responding to incidents after they occur
Correct answer: Through proactive identification of potential hazards and implementation of preventive measures
Effective risk management in Accessibility & ADA Compliance requires proactive hazard identification and preventive measures, not just reactive responses. This approach reduces incidents, improves outcomes, and protects both professionals and clients.
Question 76: How does risk management apply to daily practice in Door Operators & Interlocks for Certified Elevator Technician professionals?
- Only through responding to incidents after they occur
- Through annual safety audits exclusively
- By avoiding high-risk situations entirely
- Through proactive identification of potential hazards and implementation of preventive measures (Correct answer)
Correct answer: Through proactive identification of potential hazards and implementation of preventive measures
Effective risk management in Door Operators & Interlocks requires proactive hazard identification and preventive measures, not just reactive responses. This approach reduces incidents, improves outcomes, and protects both professionals and clients.
Question 77: What is the function of an 'up-direction' contactor in a traditional relay-logic elevator controller?
- Energizes the motor for counterclockwise rotation to move the car downward
- Applies holding current to the electromagnetic brake
- Reverses motor phase sequence to drive the car in the up direction (Correct answer)
- Controls the speed of the motor during upward travel only
Correct answer: Reverses motor phase sequence to drive the car in the up direction
The up-direction contactor reverses the phase sequence of the motor supply, causing the motor to rotate in the direction that moves the car upward.
Question 78: What is the purpose of a 'top-of-car inspection' (TOCI) station in elevator electrical design?
- Provides emergency lighting for hoistway inspection
- Allows the motor room technician to monitor the car position from above
- Transfers control authority to the car top, limits speed to inspection speed, and requires continuous pressure operation (Correct answer)
- Bypasses the door contacts during annual inspection
Correct answer: Transfers control authority to the car top, limits speed to inspection speed, and requires continuous pressure operation
The TOCI station transfers control to the car top, restricts speed to no more than 150 ft/min (inspection speed), and requires constant-pressure operation for safe personnel movement.
Question 79: What is the purpose of a limit switch in elevator systems?
- Measure speed
- Signal for door closing
- Control car lighting
- Prevent over-travel of the elevator car (Correct answer)
Correct answer: Prevent over-travel of the elevator car
Limit switches prevent the elevator from moving beyond safe boundaries by cutting off power when limits are reached.
Question 80: What causes 'nuisance tripping' of the elevator main line circuit breaker?
- Incorrect phase sequence at the main disconnect
- Excessive motor starting current exceeding the breaker's instantaneous trip rating (Correct answer)
- Low insulation resistance in the traveling cable
- A failed encoder sending false speed signals
Correct answer: Excessive motor starting current exceeding the breaker's instantaneous trip rating
High inrush current during motor starting can exceed the instantaneous trip threshold of an incorrectly sized breaker, causing nuisance trips.
Question 81: Under OSHA 29 CFR 1910.68, the maximum rated load for a manlift step platform is:
- 300 lbs
- 200 lbs
- 250 lbs (Correct answer)
- 350 lbs
Correct answer: 250 lbs
OSHA 29 CFR 1910.68 specifies that manlift step platforms must be designed to carry a maximum load of 250 lbs.
Question 82: Under ADA, elevator hall call buttons must be located at what maximum height above the finished floor?
- 48 inches for all configurations
- 60 inches maximum regardless of approach
- 42 inches for side reach and 54 inches for forward reach
- 54 inches for side reach and 48 inches for forward reach (Correct answer)
Correct answer: 54 inches for side reach and 48 inches for forward reach
ADA specifies a maximum height of 54 inches for side reach and 48 inches for forward reach for elevator hall call buttons.
Question 83: What is the purpose of the 'independent service' mode on an elevator in relation to emergency operations?
- It enables the elevator to run at reduced speed only
- It activates Phase I recall automatically
- It bypasses all safety devices
- It removes the elevator from normal group dispatching for single-car manual control (Correct answer)
Correct answer: It removes the elevator from normal group dispatching for single-car manual control
Independent service removes the car from automatic group dispatching so it can be operated manually, but it is not an emergency mode like Phase II.
Question 84: What is the function of the elevator buffer?
- Absorb energy at the shaft base (Correct answer)
- Provide car acceleration
- Control door movement
- Measure car weight
Correct answer: Absorb energy at the shaft base
Buffers are installed at the bottom of the hoistway to absorb impact and stop the car safely if it travels too far downward.
Question 85: On a pallet-type moving walk, what retains the pallets in their proper lateral position along the track?
- Comb plate teeth
- Guide shoes riding on the truss chord
- Pallet axle flanges engaging guide rails (Correct answer)
- The handrail drive belt
Correct answer: Pallet axle flanges engaging guide rails
Pallet axle flanges or guide wheels engage dedicated guide rails in the truss to keep each pallet laterally aligned throughout the circuit.
Question 86: Per ASME A17.1, the minimum conductor size permitted for elevator power circuits is:
- 18 AWG, the standard minimum for fixture wiring
- 14 AWG, ensuring adequate current capacity and mechanical strength (Correct answer)
- 10 AWG, providing a conservative safety margin for motor loads
- 22 AWG, consistent with low-voltage control circuit minimums
Correct answer: 14 AWG, ensuring adequate current capacity and mechanical strength
ASME A17.1 specifies No. 14 AWG as the minimum conductor size for elevator power circuits, balancing current-carrying capacity with mechanical durability in the hoistway environment.
Question 87: Which standard of practice is MOST important for ensuring quality in Door Operators & Interlocks?
- Using the most advanced technology available regardless of need
- Minimizing documentation to focus on practical work
- Following evidence-based protocols while adapting to specific circumstances (Correct answer)
- Strictly adhering to the same procedure in every situation
Correct answer: Following evidence-based protocols while adapting to specific circumstances
Evidence-based protocols provide a foundation of proven practices, but effective Certified Elevator Technician professionals must also adapt their approach based on specific circumstances and individual case needs within Door Operators & Interlocks.
Question 88: What type of guide shoe uses a renewable liner that slides along the rail?
- Roller guide shoe
- Sliding (friction) guide shoe (Correct answer)
- Magnetic guide shoe
- Compound guide shoe
Correct answer: Sliding (friction) guide shoe
Sliding guide shoes use replaceable plastic or bronze liners that contact and slide along the three faces of the T-rail, providing guidance with low maintenance.
Question 89: The handrail speed on an escalator must be maintained within what tolerance of step speed?
- ±1%
- ±10%
- ±2%
- ±5% (Correct answer)
Correct answer: ±5%
ASME A17.1 requires handrail speed to be within ±2% of step speed to prevent passenger imbalance, though some codes cite 0–2% above step speed.
Question 90: What is the purpose of the compensation ropes or chains in a high-rise traction elevator?
- To connect the governor to the safety device
- To limit car travel speed
- To provide emergency braking
- To balance the weight of the hoist ropes between car and counterweight (Correct answer)
Correct answer: To balance the weight of the hoist ropes between car and counterweight
Compensation ropes or chains counteract the changing weight imbalance of hoist ropes as the car travels through long hoistways.
Question 91: Which edition of the ICC/ANSI A117.1 standard governs accessible elevator cab dimensions used in ADA compliance?
- Always the 2017 edition
- Always the 2009 edition
- The edition adopted by the local jurisdiction (Correct answer)
- The edition in force at original construction
Correct answer: The edition adopted by the local jurisdiction
Accessibility requirements default to the ICC/ANSI A117.1 edition adopted by the local jurisdiction, which varies by state and municipality.
Question 92: When a new microprocessor controller is installed during modernization, what must be provided in the machine room for the new system?
- A new pit access ladder
- Updated wiring diagrams reflecting the as-installed condition (Correct answer)
- A separate utility sink
- A dedicated fire suppression system
Correct answer: Updated wiring diagrams reflecting the as-installed condition
ASME A17.1 requires current, accurate wiring diagrams to be available in the machine room so technicians can safely service the system.
Question 93: An elevator's door reopens immediately after closing without an obstruction. The FIRST component to check is:
- The door close limit switch
- The door safety edge or light curtain circuit (Correct answer)
- The floor selector position feedback
- The car operating panel close button wiring
Correct answer: The door safety edge or light curtain circuit
An unobstructed door that reverses points to a fault signal from the safety edge or light curtain circuit, making it appear the door is blocked when it is not.
Question 94: What is the primary purpose of adding a car position indicator (CPI) during an elevator modernization?
- To provide passengers with real-time floor position information, improving user experience and code compliance (Correct answer)
- To reduce the controller's processing load
- To replace the need for leveling switches
- To display advertising content on the car interior
Correct answer: To provide passengers with real-time floor position information, improving user experience and code compliance
CPIs inform passengers of the car's current floor location and direction, meeting modern accessibility and user experience standards often required by updated codes.
Question 95: What is the purpose of a 'buffer stopping switch' in the elevator pit electrical circuit?
- Cuts power to the pit lighting when the car is above the pit
- Resets the buffer oil level after compression
- Activates the pit stop switch alarm
- Opens the safety circuit when the car strikes an oil or spring buffer (Correct answer)
Correct answer: Opens the safety circuit when the car strikes an oil or spring buffer
The buffer stopping switch opens the safety circuit when the car or counterweight contacts a buffer, cutting power and preventing further car movement.
Question 96: Which condition would require immediate replacement of a governor rope?
- Minor surface oxidation
- Slight kinking from installation
- Six broken wires in one lay length (Correct answer)
- One broken wire in any strand
Correct answer: Six broken wires in one lay length
ASME A17.1 requires governor rope replacement when six or more broken wires are found in one lay length of the rope.
Question 97: Which component converts AC to DC for elevator control circuits?
- Capacitor
- Transformer
- Resistor
- Rectifier (Correct answer)
Correct answer: Rectifier
Rectifiers are used to convert alternating current (AC) to direct current (DC) for elevator control components.
Question 98: What is the consequence of operating a traction elevator with unequal rope tensions?
- Increased ride comfort due to load redistribution
- Automatic speed regulation by the controller
- Overloading of some ropes and premature wear, reducing the overall safety margin (Correct answer)
- Reduced energy consumption by the motor
Correct answer: Overloading of some ropes and premature wear, reducing the overall safety margin
Unequal tensions concentrate load on fewer ropes, reducing the effective safety factor and accelerating fatigue failure of the overloaded ropes.
Question 99: Tactile floor designations on elevator jambs must be mounted at what height measured from the finished floor per ADA?
- 54 inches (1370 mm) to center
- 48 inches (1220 mm) to center
- 60 inches (1525 mm) to center (Correct answer)
- 72 inches (1830 mm) to center
Correct answer: 60 inches (1525 mm) to center
ADA Section 407.2.3 requires floor designations on elevator hoistway jambs to be centered at 60 inches above the finished floor so they are reachable for tactile reading.
Question 100: Under ASME A17.1, what is the purpose of the 'car leveling device' and what tolerance is permitted?
- Stops the car within ±3 inches of landing
- Stops the car within ±1 inch of landing
- Stops the car within ±2 inches of landing
- Stops the car within ±½ inch of landing (Correct answer)
Correct answer: Stops the car within ±½ inch of landing
ASME A17.1 requires car leveling devices to bring the car to within ±½ inch of the landing floor level to ensure safe egress.
Certified Elevator Technician (CET)
The NAEC CET certification validates advanced knowledge and skill in elevator installation, maintenance, repair, and safety compliance. It is the professional benchmark for elevator technicians, covering electrical systems, mechanical systems, safety codes, and troubleshooting.
Exam Rules
- You can skip questions and return to them later
- Flag questions for review before submitting
- No feedback shown until you submit the entire exam
- Unanswered questions count as wrong — answer everything
- 10 pretest questions are mixed in and don't affect your score
- Timer auto-submits when time runs out
- Your progress is auto-saved every 30 seconds