  1. The smallest input change that a measuring device can detect and display is known as the gauge's:

    Answer: Discrimination (resolution)

    Discrimination (also called resolution or smallest readable unit) is the smallest detectable increment that the measurement device can resolve.

  2. According to AIAG MSA guidelines, the measurement device's resolution (discrimination) should be at most what fraction of the process variation or tolerance?

    Answer: 1/10

    The gauge's smallest readable increment should be no greater than 1/10 of either the process variation (6σ) or the engineering tolerance to ensure adequate discrimination.

  3. In a Type 1 Gauge Study, which two key statistics are primarily evaluated?

    Answer: Cg and Cgk

    A Type 1 Gauge Study evaluates Cg (gauge capability) and Cgk (gauge capability considering bias) by having a single operator measure a reference part multiple times.

  4. If operator-by-part interaction is found to be statistically significant in an ANOVA Gauge R&R, what is the most likely root cause?

    Answer: Operators use inconsistent techniques that affect certain parts differently

    A significant operator-by-part interaction means that operators rank or measure parts differently from each other, suggesting non-uniform operator technique or part-handling differences.

  5. A measurement system evaluation shows σ²_total = 1.00, σ²_part = 0.85, σ²_GRR = 0.15. What is the %GRR (study variation method, using variance)?

    Answer: 15%

    %GRR using variance contribution = σ²_GRR / σ²_total × 100 = 0.15/1.00 × 100 = 15%.

  6. In an attribute agreement analysis for a go/no-go gauge, 'within-appraiser agreement' measures:

    Answer: How consistently one appraiser classifies the same parts across multiple trials

    Within-appraiser agreement (repeatability for attribute systems) evaluates whether a single appraiser makes the same accept/reject decision on the same part across repeated trials.

  7. Which action best addresses high Reproducibility (operator-to-operator variation) found in a Gauge R&R study?

    Answer: Standardize operator training and written measurement procedures