  1. The AIAG MSA manual recommends that %Tolerance (P/T ratio) be used when the primary concern is:

    Answer: Determining if the gage is adequate to hold the product specification

    The P/T ratio (precision-to-tolerance) compares gage variation to the specification tolerance, making it the right metric when conformance decisions are the focus.

  2. A measurement system has a %R&R of 22% and an ndc of 3. Which statement is most accurate?

    Answer: The system is unacceptable primarily because ndc is below 5

    An ndc below 5 means the system cannot distinguish enough categories within the process variation, making it inadequate regardless of %R&R being marginally acceptable.

  3. In an MSA study for a vision inspection system, 50 parts (25 good, 25 defective) are presented to 3 operators twice. This study design best evaluates:

    Answer: Attribute agreement analysis (Kappa) for an automated or human visual inspector

    Presenting known-status parts to multiple appraisers in replicated trials is the standard attribute agreement analysis design, evaluated using Kappa statistics.

  4. Which of the following is a correct interpretation of 'bias' in a measurement system?

    Answer: The systematic difference between the observed average measurement and the true (reference) value

    Bias is the systematic (consistent) error — the offset between the measurement system's average reading and the accepted reference value.

  5. A Six Sigma team discovers that calibration records for a critical measurement device are 6 months overdue. What should be done FIRST before using data collected during that period?

    Answer: Conduct an immediate bias and stability study to assess the magnitude of potential error

    Assessing the current bias and reviewing historical stability data helps quantify the risk before deciding whether prior data is usable or must be discarded.

  6. In a Gage R&R ANOVA table, which F-ratio is used to test whether part-to-part variation is statistically significant?

    Answer: F = MS(Part) / MS(Operator×Part)

    In a crossed Gage R&R ANOVA, Part variation is tested against the Operator×Part interaction term as the appropriate error term.

  7. A temperature sensor is used to monitor a process over the range 50°C–250°C. A linearity study reveals the bias is negligible at 50°C but reaches +4°C at 250°C. What action is most appropriate?

    Answer: Apply a correction factor at high temperatures or replace the sensor

    Non-constant bias across the operating range (poor linearity) requires either a correction factor at affected values or replacing the sensor with one that performs linearly.