โ† All CHT Flashcard Decks

Infection Control and Patient Safety in Dialysis Flashcards

6 cards from real CHT practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 6 Infection Control and Patient Safety in Dialysis flashcards as text
  1. The acceptable alcohol concentration in hand sanitizers effective for healthcare use against most viruses and bacteria is:

    Answer: 60-95% ethanol or isopropanol

    Hand sanitizers must contain 60-95% alcohol to denature microbial proteins effectively; lower concentrations lack sufficient antimicrobial activity.

  2. Patient safety reporting systems in dialysis facilities are most effective when they use:

    Answer: Non-punitive, anonymous reporting to encourage near-miss and error disclosure

    Non-punitive reporting cultures encourage staff to report near-misses and errors without fear of punishment, enabling learning and systemic safety improvements.

  3. Which practice is PROHIBITED in dialysis treatment areas to prevent cross-contamination between patients?

    Answer: Bringing medication carts, trays, or supplies used for one patient to another patient's station without disinfection

    Medication carts and supplies moved between patient stations without disinfection risk transferring bloodborne pathogens via contaminated surfaces.

  4. Which organization publishes the Conditions for Coverage (CfC) that dialysis facilities must meet to receive Medicare reimbursement?

    Answer: CMS (Centers for Medicare & Medicaid Services)

    CMS publishes and enforces the ESRD Conditions for Coverage, which establish the minimum standards dialysis facilities must meet for Medicare certification.

  5. Two-patient identification checks before initiating hemodialysis include verifying:

    Answer: Patient name and date of birth (or second identifier) against the treatment order

    Two-patient identifiers (name plus DOB or MRN) verified against the treatment order prevent wrong-patient dialysis, a serious preventable safety event.

  6. The purpose of performing a machine safety check before each hemodialysis treatment includes verifying:

    Answer: Conductivity, temperature, pH (bicarbonate balance), blood leak detector function, and air detector function

    Pre-treatment machine safety checks verify that dialysate parameters and safety alarms are properly set and functional before connecting the patient to the extracorporeal circuit.