  1. What is the primary advantage of a daylight harvesting control system in perimeter office zones?

    Answer: It dims or switches off electric lights when daylight provides sufficient illuminance

    Daylight harvesting uses photosensors to continuously dim or switch electric lighting when sufficient natural light is available, reducing electrical energy use.

  2. A 480V/277V three-phase system distributes power to lighting panels. What is the advantage of 277V branch circuits for commercial lighting?

    Answer: Lower current for the same wattage reduces conductor and breaker costs

    At 277V, the current for the same wattage load is approximately half that at 120V, allowing smaller conductors and reducing distribution losses.

  3. Which LED driver topology provides the best efficiency over a wide dimming range?

    Answer: Pulse-width modulation (PWM) driver

    PWM drivers switch current on and off rapidly, maintaining full LED drive current per pulse so efficacy stays high even at low dim levels.

  4. An auditor calculates that replacing 200 W metal halide high-bay fixtures with 90 W LED high-bays will save 22 kW of demand. At $12/kW/month demand charge, what is the annual demand savings?

    Answer: $3,168

    22 kW × $12/kW/month × 12 months = $3,168 per year in demand charge savings.

  5. What does 'stroboscopic effect' mean in the context of lighting for rotating machinery?

    Answer: The apparent slowing or stopping of rotating parts when light flickers at multiples of rotational speed

    When light flickers at a frequency equal to or a multiple of the rotation speed, moving parts can appear stationary, creating a safety hazard.

  6. Under ASHRAE 90.1, which control is mandatory for all interior lighting in spaces larger than 5,000 ft²?

    Answer: Automatic time-switch controls

    ASHRAE 90.1 requires automatic time-switch or scheduling controls for interior lighting in spaces over 5,000 ft² to ensure lights are turned off after hours.

  7. Which transformer type produces the lowest no-load (core) losses for distribution to lighting panels?

    Answer: Amorphous core transformer

    Amorphous core transformers use an amorphous metal alloy that significantly reduces hysteresis losses, cutting no-load losses by up to 70% versus standard silicon-steel cores.