← All CEM Flashcard Decks

Methods and Strategies Flashcards

7 cards from real CEM practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Methods and Strategies flashcards as text
  1. Which measurement and verification (M&V) option under IPMVP is MOST appropriate when it is difficult to isolate individual measure savings?

    Answer: Option C — Whole Facility

    Option C uses whole-facility metering to track energy changes, making it suitable when multiple measures interact or when individual isolation is impractical.

  2. What is the purpose of establishing an 'energy baseline' before implementing conservation measures?

    Answer: To provide a reference for quantifying savings after implementation

    A baseline documents pre-retrofit energy use so that post-implementation consumption can be compared to quantify actual savings achieved.

  3. A CEM is developing an energy master plan. Which element is MOST critical to include for long-term strategic success?

    Answer: Aligned energy goals with organizational mission and capital planning cycles

    An effective energy master plan integrates energy goals with organizational priorities and budget cycles to ensure sustained commitment and funding.

  4. Which strategy is MOST effective for managing electricity costs associated with time-of-use (TOU) rates?

    Answer: Shifting non-critical loads to off-peak hours

    Under TOU rates, electricity costs more during peak hours, so shifting flexible loads — like chilling, laundry, or charging — to off-peak periods directly reduces bills.

  5. An energy manager discovers that a chiller plant is running at 15% load most of the time. What strategy should be evaluated FIRST?

    Answer: Stage chillers so fewer machines run at higher, more efficient loads

    Chillers operate most efficiently near 80–90% of their design load; staging fewer units at higher loads eliminates the severe efficiency penalty of part-load operation.

  6. What is 'retrocommissioning' (RCx) as an energy management strategy?

    Answer: Systematically tuning existing building systems to restore or exceed original design performance

    Retrocommissioning investigates and corrects faults in existing systems — such as controls drift, sensor errors, and scheduling problems — without capital replacement.

  7. A CEM wants to benchmark a hospital's energy performance. Which tool is MOST appropriate for US facilities?

    Answer: ENERGY STAR Portfolio Manager

    ENERGY STAR Portfolio Manager provides 1–100 energy performance scores normalized for weather and occupancy, enabling apples-to-apples comparison with similar US facilities.