Building Codes & Standards Flashcards

7 cards from real CCI practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Building Codes & Standards flashcards as text
  1. Under the IBC, what is the maximum allowable floor area for a single-story Type VB construction building with no sprinkler system used as a business occupancy (Group B)?

    Answer: 19,000 sq ft

    IBC Table 506.2 limits a single-story, non-sprinklered Type VB Group B occupancy to 19,000 sq ft of allowable floor area.

  2. Which ASTM standard governs the standard specification for ready-mixed concrete?

    Answer: ASTM C94

    ASTM C94 is the Standard Specification for Ready-Mixed Concrete, covering mixing, delivery, and uniformity requirements.

  3. The IBC requires a handrail on at least one side of a stair when the stair has how many or more risers?

    Answer: 4

    IBC Section 1012.1 requires handrails on stairs with four or more risers.

  4. Which code body publishes the National Electrical Code (NEC) adopted by most US jurisdictions?

    Answer: National Fire Protection Association (NFPA)

    The National Electrical Code (NFPA 70) is published by the National Fire Protection Association and is the basis for electrical installation requirements nationwide.

  5. Under the IBC, a building's 'occupant load' for egress design is primarily determined by:

    Answer: Dividing the occupiable floor area by the applicable occupant load factor

    IBC Section 1004.1 requires occupant load to be calculated by dividing the floor area by the occupant load factor from Table 1004.5.

  6. What does the acronym 'AHJ' stand for in the context of building codes and inspections?

    Answer: Authority Having Jurisdiction

    AHJ stands for Authority Having Jurisdiction, the organization, office, or individual responsible for enforcing code requirements.

  7. According to IBC Section 1604, the load combination that must be checked for strength design includes which of the following?

    Answer: 1.2D + 1.6L

    IBC Section 1604.3.1 requires checking the strength load combination 1.2D + 1.6L (among others), where D is dead load and L is live load.