  1. A patient with diabetes has non-compressible ankle vessels on ABI testing. Which alternative measurement is most appropriate?

    Answer: Toe-brachial index

    The toe-brachial index (TBI) is the preferred alternative because digital arteries are rarely calcified in diabetic patients.

  2. During exercise ABI testing, a patient's ABI drops from 0.85 at rest to 0.52 immediately after treadmill walking. What does this indicate?

    Answer: Hemodynamically significant arterial stenosis

    A post-exercise ABI drop of ≥20% or to below 0.90 confirms hemodynamically significant PAD not apparent at rest.

  3. Which artery is the most common site of atherosclerotic occlusion in the lower extremity?

    Answer: Superficial femoral artery at the adductor canal

    The superficial femoral artery at the adductor (Hunter's) canal is the most common site of lower extremity atherosclerotic occlusion.

  4. What is the significance of a high-thigh pressure that is lower than the brachial pressure in segmental limb pressure testing?

    Answer: Suggests aortoiliac occlusive disease

    A high-thigh pressure lower than brachial pressure indicates inflow disease at the aortoiliac level.

  5. On a lower extremity duplex scan, color flow imaging shows aliasing at a focal arterial segment. What is the primary cause of aliasing?

    Answer: Velocity exceeding the Nyquist limit

    Aliasing occurs when blood flow velocity exceeds the Nyquist limit (half the pulse repetition frequency), causing color wraparound.

  6. A patient undergoing lower extremity arterial evaluation has a biphasic waveform at the posterior tibial artery. What does this suggest compared to a normal triphasic waveform?

    Answer: Mild proximal disease with preserved forward flow

    A biphasic waveform with loss of the reverse flow component suggests mild to moderate proximal arterial disease reducing peripheral resistance.

  7. In peripheral arterial duplex imaging, what insonation angle should be maintained for accurate velocity measurements?

    Answer: 60 degrees or less

    An angle of 60 degrees or less is required for accurate Doppler velocity measurements; angles above 60 degrees introduce significant error.