โ† All ASHE Flashcard Decks

Regulatory Compliance & Safety Standards Flashcards

7 cards from real ASHE practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Regulatory Compliance & Safety Standards flashcards as text
  1. The OSHA Hazard Communication Standard (HazCom, 29 CFR 1910.1200) requires Safety Data Sheets to follow which international format?

    Answer: GHS 16-section format

    HazCom 2012 aligned U.S. requirements with the Globally Harmonized System (GHS), mandating a standardized 16-section Safety Data Sheet format.

  2. A Permit-Required Confined Space in a hospital (per OSHA 29 CFR 1910.146) must have which feature that distinguishes it from a non-permit space?

    Answer: It contains or has a potential to contain a serious hazard

    A permit-required confined space has limited entry/exit AND contains or has potential to contain a serious physical or atmospheric hazard, requiring a written permit for entry.

  3. Under NFPA 99, which category of piped medical gas requires the highest level of risk assessment due to direct life-support dependency?

    Answer: Category 1

    Category 1 under NFPA 99 applies to spaces where failure of equipment or a system is likely to cause major injury or death to patients or caregivers, requiring the most stringent standards.

  4. A healthcare facility's Environment of Care Management Plans must be evaluated for effectiveness at minimum how often per TJC standards?

    Answer: Annually

    The Joint Commission requires that Environment of Care management plans (Safety, Security, Hazardous Materials, Fire, Medical Equipment, Utilities) be reviewed and evaluated annually.

  5. Which federal law requires healthcare facilities to report releases of hazardous substances above reportable quantities to the National Response Center?

    Answer: CERCLA/SARA Title III (EPCRA)

    EPCRA (Emergency Planning and Community Right-to-Know Act), enacted as SARA Title III, requires immediate notification to the NRC for releases of listed hazardous substances above reportable quantities.

  6. According to CMS guidelines, a hospital's emergency operations plan must be tested through a full-scale exercise at minimum:

    Answer: Twice per year, with one community-based exercise every 2 years

    CMS CoP requires hospitals to conduct two emergency response exercises per year, with at least one community-based full-scale exercise once every two years.

  7. Under NFPA 101 healthcare occupancy requirements, doors to hazardous areas (e.g., soiled linen rooms) must have a minimum fire resistance rating of:

    Answer: 45 minutes

    NFPA 101 requires that doors to hazardous areas in healthcare occupancies have a minimum 45-minute fire protection rating and be self-closing.