ARRT Computed Tomography (CT) Certification Examination โ Questions and Answers
Question 1: What is preventive maintenance?
- Cleaning only
- Replacing all equipment annually
- Regular scheduled maintenance to prevent equipment failure (Correct answer)
- Fixing equipment after it breaks
Correct answer: Regular scheduled maintenance to prevent equipment failure
Preventive maintenance involves regular, scheduled inspections and servicing to prevent unexpected breakdowns and extend equipment life.
Question 2: Adaptive statistical iterative reconstruction (ASIR) improves CT image quality primarily by:
- Increasing spatial resolution beyond filtered back projection
- Improving temporal resolution
- Eliminating beam hardening artifacts
- Reducing image noise while maintaining resolution (Correct answer)
Correct answer: Reducing image noise while maintaining resolution
ASIR uses statistical modeling to reduce noise, allowing diagnostic images at lower dose without proportional loss of spatial resolution.
Question 3: What is the Continuing Qualifications Requirements (CQR) process for ARRT CT certification?
- A self-assessment and continuing education program every 10 years (Correct answer)
- A mandatory exam that must be passed every 5 years
- A review of clinical competencies performed every year
- A recertification application process every 5 years
Correct answer: A self-assessment and continuing education program every 10 years
The Continuing Qualifications Requirements (CQR) is a distinct process from the biennial CE requirements. For ARRT CT certification, CQR involves a self-assessment and targeted continuing education program that must be completed every 10 years. This ensures long-term competency and addresses any identified knowledge gaps.
Question 4: Which of the following activities qualifies as a Category A continuing education credit for ARRT recertification?
- Reviewing patient charts for quality assurance
- Performing additional clinical shifts
- Attending an ARRT-approved educational seminar (Correct answer)
- Reading a radiology textbook independently
Correct answer: Attending an ARRT-approved educational seminar
Category A credits require structured learning through ARRT-approved providers such as accredited seminars, courses, or self-assessment activities.
Question 5: What does 'afterglow' (or 'ghosting') in CT solid-state detectors cause?
- Increased image noise due to photon starvation
- Ring artifacts from a single failed detector channel
- Reduced spatial resolution due to detector cross-talk
- Residual signal carried over from prior projections, causing streak artifacts (Correct answer)
Correct answer: Residual signal carried over from prior projections, causing streak artifacts
Afterglow occurs when scintillator crystals continue to emit light after X-ray exposure ends, carrying residual signal into subsequent projections and causing streak or shading artifacts.
Question 6: If an ARRT CT candidate fails the examination, what is the mandatory waiting period before retaking it?
- 30 days
- 180 days
- 90 days (Correct answer)
- One full year
Correct answer: 90 days
ARRT mandates a 90-day waiting period between examination attempts for post-primary specialty exams including CT.
Question 7: How does ARRT CT certification support a technologist's participation in quality improvement initiatives within their department?
- It disqualifies technologists from serving on quality committees
- It provides the advanced protocol and dose optimization knowledge needed to contribute meaningfully to QI projects (Correct answer)
- It transfers QI responsibilities entirely to the radiologist
- It only applies to patient scheduling improvements
Correct answer: It provides the advanced protocol and dose optimization knowledge needed to contribute meaningfully to QI projects
The depth of CT knowledge required for ARRT certification equips technologists to identify protocol inefficiencies, dose issues, and image quality problems in QI settings.
Question 8: What does OPSEC stand for?
- Operational Section
- Optional Security
- Operating System Executive
- Operations Security (Correct answer)
Correct answer: Operations Security
OPSEC protects critical information from adversaries by identifying and safeguarding sensitive data.
Question 9: Which statement about ARRT CT certification and malpractice risk is most accurate?
- Only radiologists' credentials affect malpractice outcomes
- Facilities employing certified technologists may face reduced liability exposure due to documented staff competency (Correct answer)
- Certification increases malpractice risk because higher standards are expected
- Certification has no legal or liability implications
Correct answer: Facilities employing certified technologists may face reduced liability exposure due to documented staff competency
Documented staff competency through recognized credentials can support a facility's defense in litigation by showing due diligence in hiring and maintaining qualified staff.
Question 10: How long is the ARRT CT post-primary certification credential valid before renewal is required?
- 2 years (biennium) (Correct answer)
- 1 year
- Lifetime with no renewal
- 5 years
Correct answer: 2 years (biennium)
Like all ARRT credentials, CT post-primary certification must be renewed every two years through the biennial renewal process.
Question 11: Under ARRT rules, how long does a candidate have to complete the examination after their application is approved?
- 30 days
- 3 years
- 1 year (Correct answer)
- 90 days
Correct answer: 1 year
Once approved, candidates generally have a 1-year eligibility window during which they must schedule and complete the examination.
Question 12: What is the minimum passing score typically required on the ARRT CT certification examination?
- 75
- 85
- 68
- The ARRT uses a scaled score, not a percentage (Correct answer)
Correct answer: The ARRT uses a scaled score, not a percentage
ARRT reports exam results as a scaled score rather than a raw percentage, with 75 being the passing scaled score.
Question 13: What is the minimum passing score for the ARRT CT certification exam?
- 75 (Correct answer)
- 65
- 80
- 70
Correct answer: 75
To successfully pass the ARRT CT certification exam, candidates must achieve a scaled score of 75 or higher. This score represents the minimum level of competency required by the ARRT to demonstrate proficiency in computed tomography. Scores are scaled to ensure fairness across different exam forms.
Question 14: Which characteristic best describes a nonionic iodinated contrast medium compared to an ionic agent?
- Higher osmolality and greater ionization in solution
- Lower iodine concentration per milliliter
- Identical osmolality but with ionic charge
- Lower osmolality and does not dissociate into ions in solution (Correct answer)
Correct answer: Lower osmolality and does not dissociate into ions in solution
Nonionic contrast media remain intact molecules in solution, yielding lower osmolality and fewer adverse hemodynamic and chemotoxic effects than ionic agents.
Question 15: To troubleshoot a CT image showing significant noise (grainy appearance), the technologist should first consider adjusting which parameter?
- Reducing matrix size
- Increasing mAs (Correct answer)
- Increasing pitch
- Decreasing kVp
Correct answer: Increasing mAs
Increasing mAs raises the number of X-ray photons, directly reducing quantum noise and improving signal-to-noise ratio.
Question 16: Which of the following best describes 'overranging' (z-overscanning) in helical CT?
- Extra rotations acquired beyond the requested scan range to complete helical reconstruction (Correct answer)
- Scanning beyond the prescribed FOV diameter
- Applying too wide a display window
- Using a higher kVp than needed
Correct answer: Extra rotations acquired beyond the requested scan range to complete helical reconstruction
Overranging refers to the additional tube rotations at the start and end of a helical scan needed to reconstruct the first and last requested slices, increasing dose.
Question 17: What is the ALARA principle in radiation safety?
- All Labs And Rooms Assessed
- Always Lock And Restrict Access
- Automated Limiting Adjustment for Radiation Applications
- As Low As Reasonably Achievable โ minimize radiation exposure (Correct answer)
Correct answer: As Low As Reasonably Achievable โ minimize radiation exposure
ALARA means keeping radiation doses as low as reasonably achievable while still obtaining diagnostic-quality images, balancing benefit against risk.
Question 18: A Radiation Therapy (T) credential holder who wishes to obtain CT certification must complete which category of clinical competencies?
- CT-specific competencies as outlined in the ARRT CT content specifications (Correct answer)
- Radiography general competencies only
- No clinical competencies โ written exam only
- MRI competencies as a prerequisite
Correct answer: CT-specific competencies as outlined in the ARRT CT content specifications
All CT candidates, regardless of their primary pathway, must satisfy CT-specific clinical competency requirements.
Question 19: What is the primary reason CT scanners use slip-ring technology?
- To allow continuous gantry rotation by eliminating the need for cables to wind and unwind (Correct answer)
- To improve detector quantum efficiency
- To synchronize gantry rotation with patient respiration
- To increase the kVp range of the X-ray tube
Correct answer: To allow continuous gantry rotation by eliminating the need for cables to wind and unwind
Slip-ring technology uses electrical contacts that rotate with the gantry, enabling continuous 360ยฐ rotation without cable entanglement, which is essential for helical/spiral CT.
Question 20: Which of the following is an example of a breach of patient confidentiality?
- Documenting contrast administration in the patient's chart
- Sharing patient imaging results with the ordering physician
- Confirming a patient's identity before beginning a procedure
- Discussing a patient's case with a family member without patient consent (Correct answer)
Correct answer: Discussing a patient's case with a family member without patient consent
Under HIPAA, patient health information may not be shared with family members without the patient's explicit consent, except in specific circumstances.
Question 21: A patient with a cardiac pacemaker presents for chest CT. Which artifact should the technologist anticipate?
- Metallic streak artifact from the pacemaker leads and generator (Correct answer)
- Cupping artifact
- Ring artifact
- Windmill artifact
Correct answer: Metallic streak artifact from the pacemaker leads and generator
Pacemaker generators and leads are highly attenuating metallic objects that produce characteristic beam hardening streak artifacts on chest CT.
Question 22: A patient states, 'I am Jehovah's Witness and refuse any blood transfusion.' The radiologic technologist should:
- Document the statement and notify the supervising clinician immediately (Correct answer)
- Contact the patient's family to override the decision
- Disregard the statement as the patient may not understand their condition
- Proceed with the procedure and allow physicians to decide later
Correct answer: Document the statement and notify the supervising clinician immediately
A competent adult patient has the right to refuse treatment; the technologist must document this and notify the care team to ensure informed refusal is properly handled.
Question 23: On axial CT of the knee, the iliotibial band is best identified at which location?
- Lateral aspect of the knee, inserting on Gerdy's tubercle of the tibia (Correct answer)
- Posterolateral aspect of the knee, inserting on the femoral condyle
- Posterior to the lateral collateral ligament at the fibular head
- Anteromedial compartment between the patellar tendon and medial collateral ligament
Correct answer: Lateral aspect of the knee, inserting on Gerdy's tubercle of the tibia
The iliotibial band runs along the lateral thigh and inserts on Gerdy's tubercle on the anterolateral tibia.
Question 24: What is the ALARA principle in radiation safety?
- As Low As Reasonably Achievable โ minimize radiation exposure (Correct answer)
- Automated Limiting Adjustment for Radiation Applications
- Always Lock And Restrict Access
- All Labs And Rooms Assessed
Correct answer: As Low As Reasonably Achievable โ minimize radiation exposure
ALARA means keeping radiation doses as low as reasonably achievable while still obtaining diagnostic-quality images, balancing benefit against risk.
Question 25: What is the largest organ in the human body?
- Liver
- Heart
- Skin (Correct answer)
- Brain
Correct answer: Skin
The skin is the largest organ, covering approximately 20 square feet in adults and weighing about 8 pounds. It serves as the primary barrier against the environment.
Question 26: A patient with a serum creatinine of 1.8 mg/dL is scheduled for a contrast-enhanced CT. Which action is most appropriate?
- Notify the radiologist and consider pre-hydration protocols (Correct answer)
- Cancel the exam entirely without further evaluation
- Switch to gadolinium-based contrast agent
- Proceed normally with standard iodinated contrast dose
Correct answer: Notify the radiologist and consider pre-hydration protocols
Elevated creatinine indicates impaired renal function, requiring radiologist notification and consideration of pre-hydration or dose reduction to minimize contrast-induced nephropathy risk.
Question 27: Which of the following best describes the CT appearance of the caudate lobe of the liver?
- Located posterior to the inferior vena cava and anterior to the portal vein
- A small segment located between the IVC and the fissure for the ligamentum venosum (Correct answer)
- The largest segment of the left hepatic lobe
- Located between the gallbladder fossa and the fissure for the ligamentum teres
Correct answer: A small segment located between the IVC and the fissure for the ligamentum venosum
The caudate lobe (segment I) lies between the IVC posteriorly and the fissure for the ligamentum venosum anteriorly.
Question 28: Which of the following BEST describes noise power spectrum (NPS) in CT?
- A test of detector linearity across HU ranges
- The ratio of signal to total detector noise
- The standard deviation of HU values in a uniform phantom
- A measure of how noise is distributed across spatial frequencies in an image (Correct answer)
Correct answer: A measure of how noise is distributed across spatial frequencies in an image
NPS characterizes the frequency content of image noise, showing whether noise is more granular (high-frequency) or blotchy (low-frequency) depending on reconstruction parameters.
Question 29: Minimum intensity projection (MinIP) post-processing is particularly useful for displaying which anatomical structures?
- Air-filled airways and lung parenchyma (Correct answer)
- Solid abdominal organs
- Contrast-enhanced blood vessels
- Dense bone and calcifications
Correct answer: Air-filled airways and lung parenchyma
MinIP projects the lowest attenuation voxel along each ray, making it ideal for displaying air-containing structures like the tracheobronchial tree or emphysematous lung.
Question 30: In CT, 'effective mAs' (mAs/pitch) is important because:
- It controls the display window
- It remains constant regardless of pitch, maintaining image noise consistency (Correct answer)
- It sets the rotation time only
- It determines the field of view
Correct answer: It remains constant regardless of pitch, maintaining image noise consistency
Effective mAs = mAs รท pitch; keeping this constant as pitch changes maintains consistent image noise regardless of table speed.
Question 31: How does ARRT CT certification influence a technologist's ability to work at facilities affiliated with academic medical centers?
- It is disqualifying because academic centers prefer non-certified staff
- It is irrelevant because academic centers set their own competency standards independently of ARRT
- Academic medical centers often require specialty certifications for positions involving advanced imaging modalities (Correct answer)
- It only matters for technologists who also teach radiology students
Correct answer: Academic medical centers often require specialty certifications for positions involving advanced imaging modalities
Academic medical centers frequently list specialty ARRT certifications as required or preferred qualifications for CT positions due to their high-acuity patient populations.
Question 32: A CT technologist with ARRT CT certification wants to teach at a community college radiologic technology program. How does the certification help?
- It is a disqualifying credential for educational roles
- It automatically grants a teaching license in all states
- It demonstrates content expertise that many programs require or prefer for adjunct CT instructors (Correct answer)
- It only qualifies the technologist to teach radiography, not CT specifically
Correct answer: It demonstrates content expertise that many programs require or prefer for adjunct CT instructors
Community college and vocational radiologic technology programs often require or prefer instructors to hold advanced ARRT credentials in the specialty they are teaching.
Question 33: During a CT angiography of the neck (CTA neck), the scan direction is typically:
- Cranial to caudal
- Caudal to cranial (Correct answer)
- Bidirectional simultaneously
- Axial only without table movement
Correct answer: Caudal to cranial
CTA of the neck scans caudal to cranial to follow the contrast bolus as it travels superiorly through the carotid and vertebral arteries.
Question 34: What is the first step in the ARRT CT certification process?
- Obtain a recommendation letter from an employer
- Submit an online application through the ARRT portal (Correct answer)
- Complete the required clinical competencies
- Schedule the CT certification exam
Correct answer: Submit an online application through the ARRT portal
The initial step in the ARRT CT certification process, after meeting all prerequisites, is to formally apply. This is done by submitting an online application through the official ARRT website portal. This application initiates the eligibility review and allows candidates to proceed with scheduling their exam.
Question 35: Which of the following best describes the purpose of a test bolus or bolus tracking technique in CT angiography?
- To reduce overall contrast volume needed
- To eliminate venous contamination
- To improve bone subtraction
- To determine the optimal scan delay for peak arterial enhancement (Correct answer)
Correct answer: To determine the optimal scan delay for peak arterial enhancement
Test bolus or bolus-tracking (SmartPrep/SureStar) determines when contrast peaks in the target vessel so scanning begins at the optimal moment.
Question 36: Which artifact is caused by patient movement during CT data acquisition and appears as blurring or ghosting on the reconstructed image?
- Motion artifact (Correct answer)
- Aliasing artifact
- Partial volume artifact
- Cupping artifact
Correct answer: Motion artifact
Motion artifacts result from patient movement during scanning, causing inconsistent data at each projection angle and manifesting as blurring or streaking.
Question 37: Which statement best describes an isotropic voxel in CT imaging?
- A voxel with equal dimensions in x, y, and z axes (Correct answer)
- A voxel that contains only one tissue type
- A voxel reconstructed using iterative algorithms
- A voxel with maximum attenuation value
Correct answer: A voxel with equal dimensions in x, y, and z axes
Isotropic voxels have equal measurements in all three spatial dimensions, enabling high-quality MPR and 3D reconstructions in any plane without stair-step degradation.
Question 38: CT perfusion imaging requires specialized post-processing to generate which type of parametric maps?
- Hounsfield unit histograms
- Cerebral blood flow, cerebral blood volume, and mean transit time maps (Correct answer)
- Bone mineral density scores
- Standardized uptake value (SUV) maps
Correct answer: Cerebral blood flow, cerebral blood volume, and mean transit time maps
CT perfusion post-processing applies deconvolution or maximum slope models to time-attenuation curves to produce quantitative maps of CBF, CBV, and MTT.
Question 39: What is the purpose of contrast media in CT scans?
- To reduce radiation dose
- To speed up the scan
- To enhance the visibility of specific structures and pathology (Correct answer)
- To make the patient comfortable
Correct answer: To enhance the visibility of specific structures and pathology
Contrast media (dye) enhances the visibility of blood vessels, organs, and abnormalities by changing how X-rays interact with specific tissues.
Question 40: The spatial frequency at which the MTF falls to 10% is commonly used to define:
- The optimal reconstruction FOV
- The limiting spatial resolution of the CT system (Correct answer)
- The detective quantum efficiency (DQE)
- The noise power spectrum peak
Correct answer: The limiting spatial resolution of the CT system
MTF10% represents the highest spatial frequency the system can transfer with 10% modulation, effectively defining the limiting resolution.
Question 41: A horizontal band of decreased attenuation passing through the posterior fossa on a head CT is a classic example of which artifact?
- Motion artifact from cardiac pulsation
- Ring artifact
- Beam hardening between the petrous bones (Correct answer)
- Partial volume artifact
Correct answer: Beam hardening between the petrous bones
The dense petrous temporal bones cause preferential absorption of lower-energy photons, producing a dark band across the posterior fossa known as a beam hardening artifact.
Question 42: An applicant discloses a misdemeanor conviction on the ARRT ethics pre-application. What is the likely next step?
- The misdemeanor is ignored if more than 5 years old
- ARRT conducts an ethics review before granting or denying eligibility (Correct answer)
- The applicant is approved with a probationary credential
- The application is automatically denied
Correct answer: ARRT conducts an ethics review before granting or denying eligibility
Any disclosed violation triggers an ARRT ethics review, which evaluates the nature and context of the offense before deciding eligibility.
Question 43: Stochastic effects of radiation are characterized by which of the following?
- Severity increasing proportionally with dose above the threshold
- Occurring only in radiosensitive tissues such as bone marrow
- A threshold dose below which the effect cannot occur
- No dose threshold; probability of occurrence increases with dose (Correct answer)
Correct answer: No dose threshold; probability of occurrence increases with dose
Stochastic effects (e.g., radiation-induced cancer) are assumed to have no threshold; their probability, not severity, increases with dose.
Question 44: What is the role of the ARRT Board of Trustees in the accreditation and credentialing process?
- They perform on-site inspections of clinical training sites
- They govern ARRT policy, including eligibility requirements and ethical standards (Correct answer)
- They issue state radiologic technology licenses
- They directly score individual certification examinations
Correct answer: They govern ARRT policy, including eligibility requirements and ethical standards
The ARRT Board of Trustees is the governing body responsible for setting policy, eligibility criteria, and ethical standards for the organization.
Question 45: During CT scanner acceptance testing, which test verifies that the displayed scan field of view (SFOV) matches the actual reconstructed area?
- Geometric accuracy/distance accuracy test (Correct answer)
- Detector crosstalk measurement
- Bowtie filter attenuation test
- Noise power spectrum test
Correct answer: Geometric accuracy/distance accuracy test
The geometric/distance accuracy test uses a phantom with known dimensions to confirm that distances measured on reconstructed images correspond to actual physical distances.
Question 46: Which of the following best describes a 'Category A' CE credit in the ARRT system?
- Clinical hours logged during overtime shifts
- Structured educational activity provided by an ARRT-approved sponsor (Correct answer)
- Peer-reviewed article reading logged in a journal
- Any learning activity self-reported by the technologist
Correct answer: Structured educational activity provided by an ARRT-approved sponsor
Category A credits are earned through formal, structured educational activities provided by sponsors recognized and approved by ARRT.
Question 47: What are the principles of mission command?
- Technology, firepower, logistics
- Speed, power, aggression
- Competence, mutual trust, shared understanding, commander's intent (Correct answer)
- Rank, authority, obedience
Correct answer: Competence, mutual trust, shared understanding, commander's intent
Mission command empowers subordinates through trust, shared understanding of the commander's intent, and disciplined initiative.
Question 48: How many continuing education (CE) credits must ARRT-certified technologists earn in each biennium to maintain eligibility for CT certification renewal?
- 12 credits
- 48 credits
- 24 credits (Correct answer)
- 36 credits
Correct answer: 24 credits
ARRT requires 24 CE credits per two-year renewal cycle to maintain an active, unrestricted credential.
Question 49: A technologist reconstructs axial CT images with 5 mm thickness then reforms sagittal images showing 'staircase' appearance. The BEST solution is:
- Reconstruct using thinner overlapping slices before reformatting (Correct answer)
- Increase mAs for the next scan
- Use a sharper reconstruction kernel
- Increase the reconstruction FOV
Correct answer: Reconstruct using thinner overlapping slices before reformatting
Staircase artifact on reformats results from thick axial slices; reconstructing thinner overlapping slices provides finer z-axis sampling and smoother multiplanar reformats.
Question 50: On a CT system, what does the term 'isocenter' refer to?
- The center of the patient table surface
- The center of the X-ray beam at the detector plane
- The midpoint of the scan field of view display
- The precise center of gantry rotation where the X-ray beam and detector array intersect (Correct answer)
Correct answer: The precise center of gantry rotation where the X-ray beam and detector array intersect
The isocenter is the exact point at the center of gantry rotation where the X-ray beam is focused, and proper patient centering at this point optimizes image quality and dose.
Question 51: Which premedication regimen is most commonly recommended for elective contrast administration in patients with a prior mild allergic-like contrast reaction?
- IV epinephrine 30 minutes before contrast
- Oral prednisone 50 mg at 13, 7, and 1 hour before contrast plus diphenhydramine 50 mg 1 hour before (Correct answer)
- No premedication is needed for mild prior reactions
- IV methylprednisolone only, given 1 minute before injection
Correct answer: Oral prednisone 50 mg at 13, 7, and 1 hour before contrast plus diphenhydramine 50 mg 1 hour before
The ACR-recommended premedication protocol for non-emergent cases includes oral prednisone at 13, 7, and 1 hour before contrast plus diphenhydramine 50 mg 1 hour before.
Question 52: What is the primary advantage of CT over conventional X-ray?
- CT provides cross-sectional images with superior soft tissue contrast (Correct answer)
- CT takes less time
- CT uses no radiation
- CT is cheaper
Correct answer: CT provides cross-sectional images with superior soft tissue contrast
CT provides detailed cross-sectional images with much better soft tissue contrast resolution than conventional X-rays, allowing visualization of subtle differences between tissues.
Question 53: On axial CT of the pelvis in a female patient, the uterus is characteristically located:
- Lateral to the cervix between the external iliac vessels
- Posterior to the rectum at the level of the sacrum
- Anterior to the urinary bladder in the retropubic space
- Posterior to the urinary bladder and anterior to the rectum (Correct answer)
Correct answer: Posterior to the urinary bladder and anterior to the rectum
The uterus lies between the urinary bladder anteriorly and the rectum posteriorly in the true pelvis.
Question 54: What is the window level and window width on CT images?
- Patient positioning parameters
- Settings that control the brightness and contrast of displayed images (Correct answer)
- Scan speed controls
- Physical measurements of the CT scanner
Correct answer: Settings that control the brightness and contrast of displayed images
Window level sets the center brightness (what HU appears as middle gray) and window width controls contrast range (how many HUs span from black to white).
Question 55: On axial CT, the cisterna chyli is typically located at which vertebral level and position?
- Posterior to the aorta at T4-T5
- Lateral to the right crus of the diaphragm at L1-L2
- Within the retrocrural space at T12-L1
- Anterior to L2-L3 between the aorta and IVC (Correct answer)
Correct answer: Anterior to L2-L3 between the aorta and IVC
The cisterna chyli is a lymphatic sac located anterior to the L1-L2 vertebral bodies, between the abdominal aorta and the inferior vena cava.
Question 56: Which artifact appears as a dark band between two high-density objects on a CT image and is caused by beam hardening?
- Windmill artifact
- Ring artifact
- Moirรฉ artifact
- Shadowing or 'dark band' artifact (Correct answer)
Correct answer: Shadowing or 'dark band' artifact
Dark bands (also called 'shadowing' or 'cupping' between dense objects) arise from extreme beam hardening where few low-energy photons survive to reach the detector between two dense structures.
Question 57: Partial volume averaging artifacts in CT are best reduced by which acquisition parameter adjustment?
- Increasing mAs
- Increasing kVp
- Widening the display window
- Using a thinner slice thickness (Correct answer)
Correct answer: Using a thinner slice thickness
Thinner slices reduce partial volume averaging by ensuring each voxel contains tissue from a smaller volume, improving accuracy of CT numbers.
Question 58: What is the recommended IV injection rate range for a CT angiography of the aorta using a power injector?
- 3.0โ6.0 mL/sec (Correct answer)
- 1.0โ2.0 mL/sec
- 0.5โ1.0 mL/sec
- 8.0โ10.0 mL/sec
Correct answer: 3.0โ6.0 mL/sec
CTA of the aorta typically requires injection rates of 3โ6 mL/sec to achieve sufficient intravascular iodine concentration for diagnostic arterial enhancement.
Question 59: Cardiac motion artifacts on coronary CT angiography are primarily reduced by which technique?
- High-pitch helical scanning only
- Using maximum mAs
- ECG gating to synchronize data acquisition with the cardiac cycle (Correct answer)
- Administering iodinated contrast slowly
Correct answer: ECG gating to synchronize data acquisition with the cardiac cycle
ECG gating synchronizes CT data acquisition to the relatively motion-free phases of the cardiac cycle (typically mid-diastole), reducing coronary motion artifact.
Question 60: On CT spine, which finding is most consistent with a herniated nucleus pulposus at L4-L5 causing left leg radiculopathy?
- Central disc bulge at L3-L4
- Left foraminal stenosis at L3-L4
- Right paracentral disc protrusion compressing the L4 nerve root in the lateral recess
- Left paracentral disc extrusion compressing the left L5 nerve root (Correct answer)
Correct answer: Left paracentral disc extrusion compressing the left L5 nerve root
A left paracentral extrusion at L4-L5 compresses the traversing L5 nerve root in the lateral recess, causing ipsilateral radiculopathy.
Question 61: What are the four basic tissue types in the human body?
- Skin, bone, blood, and fat
- Brain, heart, lung, and liver
- Epithelial, connective, muscle, and nervous (Correct answer)
- Smooth, rough, dense, and loose
Correct answer: Epithelial, connective, muscle, and nervous
The four fundamental tissue types are epithelial (covering/lining), connective (support/connection), muscle (movement), and nervous (communication/control).
Question 62: What does a noise index (NI) setting in automatic tube current modulation (ATCM) control?
- The target image noise level that drives mA adjustments (Correct answer)
- The amount of bowtie filter attenuation
- The number of reconstruction iterations applied
- The maximum allowed kVp during the scan
Correct answer: The target image noise level that drives mA adjustments
The noise index defines the target standard deviation of image noise; ATCM raises or lowers mA to achieve this noise target based on patient attenuation.
Question 63: What is the difference between arteries and veins?
- Arteries carry blood away from the heart; veins carry blood toward the heart (Correct answer)
- They carry the same blood in the same direction
- Veins are thicker than arteries
- Arteries are only in the lungs
Correct answer: Arteries carry blood away from the heart; veins carry blood toward the heart
Arteries carry blood away from the heart (usually oxygenated) while veins carry blood toward the heart (usually deoxygenated). Arteries have thicker walls to handle higher pressure.
Question 64: Which of the following CE topics would be MOST directly relevant to CT recertification requirements?
- MRI safety screening protocols
- Ultrasound transducer maintenance
- Advances in CT radiation dose reduction techniques (Correct answer)
- Fluoroscopy guided interventional procedures
Correct answer: Advances in CT radiation dose reduction techniques
CE focused on CT-specific topics like dose reduction directly supports the knowledge base required for CT certification maintenance.
Question 65: Which document must a CT examination candidate submit to verify completion of required clinical experience?
- A letter from the hospital CEO
- A personal statement of clinical hours
- An IRS tax form showing employment
- Attestation signed by the supervising radiologist or program director (Correct answer)
Correct answer: Attestation signed by the supervising radiologist or program director
ARRT requires an attestation from a qualified supervisor verifying that the candidate met clinical competency requirements.
Question 66: Increasing the reconstruction field of view (FOV) while keeping matrix size constant will:
- Decrease pixel size and increase spatial resolution
- Increase noise while improving contrast
- Increase pixel size and decrease spatial resolution (Correct answer)
- Have no effect on spatial resolution
Correct answer: Increase pixel size and decrease spatial resolution
Larger FOV with the same matrix means each pixel covers more area, increasing pixel size and reducing spatial resolution.
Question 67: A standard high-resolution CT (HRCT) chest protocol uses which reconstruction approach to evaluate interstitial lung disease?
- Thin slices with soft tissue kernel
- Thick slices with soft tissue kernel
- Thick slices with bone kernel
- Thin slices with high-frequency (sharp) kernel (Correct answer)
Correct answer: Thin slices with high-frequency (sharp) kernel
HRCT uses thin slices (โค1.5 mm) with a high-spatial-frequency kernel to maximize edge detail of lung parenchyma and airways.
Question 68: When scanning for acute aortic dissection, the scan range should include:
- Abdomen and pelvis only
- Chest only
- Head and neck only
- Chest, abdomen, and pelvis (Correct answer)
Correct answer: Chest, abdomen, and pelvis
Aortic dissection can extend from the aortic root to the iliac arteries, so the entire aorta from chest through pelvis must be imaged.
Question 69: Cupping artifact on a CT image of a large cylindrical phantom most likely indicates:
- Incorrect detector gain calibration
- Excessive pitch value
- Patient motion during scanning
- Beam hardening due to preferential absorption of lower-energy photons (Correct answer)
Correct answer: Beam hardening due to preferential absorption of lower-energy photons
Cupping artifact occurs because low-energy photons are preferentially absorbed by the periphery, hardening the beam and making the center appear falsely darker.
Question 70: A CT technologist notices the dose reference level (DRL) for a routine chest CT is being routinely exceeded. The BEST first step is to:
- Continue scanning since DRLs are not legally binding limits
- Review and optimize the scan protocol to determine if dose can be reduced without compromising diagnostic quality (Correct answer)
- Report the finding only to the radiologist and take no further action
- Immediately halve the mAs for all chest CT exams
Correct answer: Review and optimize the scan protocol to determine if dose can be reduced without compromising diagnostic quality
DRLs serve as benchmarks; exceeding them triggers a protocol review to identify optimization opportunities while preserving diagnostic image quality.
Question 71: Which of the following is required as proof of identity when a candidate checks in for the ARRT CT examination?
- ARRT membership card only
- Government-issued photo ID with signature (Correct answer)
- Employer-issued badge
- Social Security card
Correct answer: Government-issued photo ID with signature
Pearson VUE and ARRT require a valid, unexpired government-issued photo ID with a matching signature at check-in.
Question 72: ARRT's recertification policy allows CE credits earned through which type of structured journal activity?
- Any peer-reviewed radiology journal subscription
- ARRT-approved self-assessment modules or journal-based CE with post-tests (Correct answer)
- Informal article reading without assessment
- Department-based journal clubs without an approved sponsor
Correct answer: ARRT-approved self-assessment modules or journal-based CE with post-tests
Journal-based CE activities qualify only when they include a post-test and are offered through an ARRT-approved sponsor, not casual reading alone.
Question 73: What is the purpose of contrast media in CT scans?
- To reduce radiation dose
- To make the patient comfortable
- To enhance the visibility of specific structures and pathology (Correct answer)
- To speed up the scan
Correct answer: To enhance the visibility of specific structures and pathology
Contrast media (dye) enhances the visibility of blood vessels, organs, and abnormalities by changing how X-rays interact with specific tissues.
Question 74: Which CT finding most reliably indicates complicated acute pancreatitis?
- Pancreatic necrosis (non-enhancing parenchyma) (Correct answer)
- Peripancreatic fat stranding
- Peripancreatic fluid collections
- Pancreatic enlargement
Correct answer: Pancreatic necrosis (non-enhancing parenchyma)
Pancreatic necrosis, identified as non-enhancing parenchyma after IV contrast, is the defining feature of necrotizing pancreatitis.
Question 75: Iterative reconstruction (IR) techniques in CT offer which primary advantage over filtered back projection?
- Reduced image noise at the same or lower radiation dose (Correct answer)
- Elimination of all artifacts
- Faster reconstruction speed
- Higher spatial resolution
Correct answer: Reduced image noise at the same or lower radiation dose
IR algorithms use repeated mathematical modeling of the imaging process to suppress noise, allowing diagnostic image quality to be maintained at reduced mAs and dose.
Question 76: What is a Hounsfield unit?
- A measure of scan speed
- A unit of image resolution
- A quantitative measurement of tissue density on CT images (Correct answer)
- A unit of radiation dose
Correct answer: A quantitative measurement of tissue density on CT images
Hounsfield units (HU) measure tissue density on CT, with water at 0 HU, air at -1000 HU, and dense bone at +1000 HU or higher.
Question 77: On CT pulmonary angiography, a saddle embolus is identified. Where is this embolus located?
- Right main pulmonary artery only
- Left main pulmonary artery only
- Within segmental pulmonary arteries bilaterally
- Straddling the main pulmonary artery bifurcation (Correct answer)
Correct answer: Straddling the main pulmonary artery bifurcation
A saddle embolus straddles the bifurcation of the main pulmonary artery, occluding both left and right pulmonary arteries.
Question 78: In CT, the term 'isotropic voxel' means:
- The voxel dimensions are equal in all three axes (x, y, z) (Correct answer)
- The voxel's HU value is calibrated to water
- The voxel has no noise contribution
- The voxel represents a single tissue type
Correct answer: The voxel dimensions are equal in all three axes (x, y, z)
An isotropic voxel has equal dimensions in x, y, and z directions, enabling multiplanar reformats of equal quality in any plane.
Question 79: What are the four basic tissue types in the human body?
- Brain, heart, lung, and liver
- Epithelial, connective, muscle, and nervous (Correct answer)
- Skin, bone, blood, and fat
- Smooth, rough, dense, and loose
Correct answer: Epithelial, connective, muscle, and nervous
The four fundamental tissue types are epithelial (covering/lining), connective (support/connection), muscle (movement), and nervous (communication/control).
Question 80: How many total attempts does ARRT allow a candidate to take the CT certification examination?
- 3 attempts (Correct answer)
- Unlimited attempts
- 2 attempts
- 5 attempts
Correct answer: 3 attempts
ARRT limits candidates to 3 total attempts to pass each post-primary examination, including CT.
Question 81: What is the ALARA principle in radiation safety?
- Always Lock And Restrict Access
- As Low As Reasonably Achievable โ minimize radiation exposure (Correct answer)
- All Labs And Rooms Assessed
- Automated Limiting Adjustment for Radiation Applications
Correct answer: As Low As Reasonably Achievable โ minimize radiation exposure
ALARA means keeping radiation doses as low as reasonably achievable while still obtaining diagnostic-quality images, balancing benefit against risk.
Question 82: Which of the following correctly identifies the position of the common bile duct on axial CT?
- Anterior and to the right of the portal vein in the hepatoduodenal ligament (Correct answer)
- Posterior and to the left of the portal vein in the hepatoduodenal ligament
- Medial to the hepatic artery within the liver parenchyma
- Within the fissure for the ligamentum teres
Correct answer: Anterior and to the right of the portal vein in the hepatoduodenal ligament
In the hepatoduodenal ligament, the common bile duct lies anteriorly and to the right of the portal vein, with the hepatic artery to the left.
Question 83: Which CT quality control parameter is most directly affected by X-ray tube focal spot size?
- CT number uniformity
- Image noise
- Low-contrast detectability
- High-contrast spatial resolution (Correct answer)
Correct answer: High-contrast spatial resolution
A smaller focal spot produces sharper images with improved high-contrast spatial resolution because the geometric unsharpness is reduced.
Question 84: 3D volume rendering of CT data allows the display of internal structures through which technique?
- Selecting only the highest attenuation voxel per projection ray
- Subtracting bone from the dataset
- Assigning opacity values to voxels based on their Hounsfield units (Correct answer)
- Applying a smooth kernel to the raw data
Correct answer: Assigning opacity values to voxels based on their Hounsfield units
Volume rendering assigns transfer functions that map each HU value to a color and opacity, allowing semi-transparent visualization of multiple tissue types simultaneously.
Question 85: How often must ARRT-certified technologists complete continuing education to maintain their credentials?
- Every 3 years
- Every year
- Every 2 years (Correct answer)
- Every 5 years
Correct answer: Every 2 years
ARRT requires 24 continuing education credits every 2 years to maintain certification.
Question 86: What is the largest organ in the human body?
- Heart
- Brain
- Liver
- Skin (Correct answer)
Correct answer: Skin
The skin is the largest organ, covering approximately 20 square feet in adults and weighing about 8 pounds. It serves as the primary barrier against the environment.
Question 87: A radiologic technologist holds R.T.(R)(CT) credentials. What do the letters in parentheses each represent?
- (R) = residency completed; (CT) = computed tomography board
- (R) = state registration; (CT) = federal CT permit
- (R) = primary ARRT registration in Radiography; (CT) = post-primary CT certification (Correct answer)
- (R) = Radiology degree; (CT) = computed tomography license
Correct answer: (R) = primary ARRT registration in Radiography; (CT) = post-primary CT certification
R.T.(R) denotes primary ARRT registration in Radiography, and (CT) denotes the additional post-primary CT certification earned.
Question 88: Which factor primarily determines the z-axis (longitudinal) resolution in a multislice CT scanner?
- Reconstruction matrix size
- kVp setting
- Detector row width (Correct answer)
- Gantry rotation speed
Correct answer: Detector row width
Z-axis resolution is primarily determined by detector row width (collimation), which defines slice thickness in the longitudinal direction.
Question 89: The right coronary artery is most reliably identified on axial CT in which anatomical groove?
- Left atrioventricular groove
- Posterior interventricular groove
- Right atrioventricular (coronary) groove (Correct answer)
- Anterior interventricular groove
Correct answer: Right atrioventricular (coronary) groove
The right coronary artery runs within the right atrioventricular groove between the right atrium and right ventricle.
Question 90: Which phantom is used to measure CTDI100 according to the standard FDA/IEC protocol?
- A 16 cm diameter PMMA phantom for head and a 32 cm phantom for body (Correct answer)
- A water-filled anthropomorphic phantom
- A 32 cm diameter cylindrical PMMA phantom for head and a 16 cm phantom for body
- A 20 cm sphere filled with tissue-equivalent material
Correct answer: A 16 cm diameter PMMA phantom for head and a 32 cm phantom for body
The FDA/IEC protocol uses a 16 cm PMMA phantom for head measurements and a 32 cm phantom for body measurements to derive CTDI100.
Question 91: What does CT stand for in medical imaging?
- Cardiac Testing
- Clinical Therapy
- Computed Tomography (Correct answer)
- Central Treatment
Correct answer: Computed Tomography
CT (Computed Tomography) uses X-ray technology and computer processing to create detailed cross-sectional images of the body.
Question 92: Which scan parameter adjustment would best reduce streak artifact from dental fillings on a head/neck CT?
- Decrease tube voltage
- Use gantry tilt to avoid the plane of the fillings (Correct answer)
- Decrease rotation time
- Increase tube current (mA)
Correct answer: Use gantry tilt to avoid the plane of the fillings
Tilting the gantry angles the scan plane away from dense dental hardware, reducing the metal streak artifact through structures of interest.
Question 93: Which pancreatic landmark on CT imaging marks the junction between the head and body of the pancreas?
- The splenic artery origin from the celiac axis
- The main pancreatic duct (duct of Wirsung)
- The common bile duct entering the pancreatic head
- The superior mesenteric vein crossing the pancreas (Correct answer)
Correct answer: The superior mesenteric vein crossing the pancreas
The superior mesenteric vein crosses the anterior surface of the pancreas at the junction of the head and body.
Question 94: What is the significance of ARRT accreditation reciprocity with respect to international technologists seeking U.S. credentials?
- Foreign technologists are exempt from the ethics review
- ARRT does not grant reciprocity; international candidates must meet all ARRT eligibility requirements independently (Correct answer)
- Foreign credentials are automatically accepted as equivalent to ARRT certification
- ARRT has formal reciprocity agreements with all countries
Correct answer: ARRT does not grant reciprocity; international candidates must meet all ARRT eligibility requirements independently
ARRT does not have reciprocity agreements with foreign credentialing bodies; all candidates must independently meet ARRT's eligibility and examination requirements.
Question 95: What is the window level and window width on CT images?
- Patient positioning parameters
- Scan speed controls
- Physical measurements of the CT scanner
- Settings that control the brightness and contrast of displayed images (Correct answer)
Correct answer: Settings that control the brightness and contrast of displayed images
Window level sets the center brightness (what HU appears as middle gray) and window width controls contrast range (how many HUs span from black to white).
Question 96: On a coronal CT reconstruction, the right hemidiaphragm is typically higher than the left because:
- The spleen is positioned more inferiorly than the liver
- The right lung is larger and displaces the diaphragm inferiorly
- The right crus of the diaphragm is thicker than the left
- The liver occupies the right upper quadrant and elevates the right hemidiaphragm (Correct answer)
Correct answer: The liver occupies the right upper quadrant and elevates the right hemidiaphragm
The mass of the liver beneath the right hemidiaphragm elevates it approximately half a rib space higher than the left.
Question 97: On an axial CT image at the level of the carina, which structure lies immediately posterior to the ascending aorta?
- Left pulmonary artery
- Superior vena cava
- Right pulmonary artery (Correct answer)
- Azygos vein
Correct answer: Right pulmonary artery
The right pulmonary artery passes posterior to the ascending aorta at the level of the carina.
Question 98: On axial brain CT, the internal capsule is bounded medially by which structure?
- Caudate nucleus (Correct answer)
- Globus pallidus
- Putamen
- Thalamus
Correct answer: Caudate nucleus
The anterior limb of the internal capsule is bounded medially by the head of the caudate nucleus.
Question 99: Which of the following is a non-financial benefit of ARRT CT certification that directly impacts a technologist's daily work?
- Increased confidence and clinical decision-making ability in CT protocols (Correct answer)
- Reduced number of CT scans assigned per shift
- Exemption from hospital-wide mandatory training
- Automatic scheduling priority for day shifts
Correct answer: Increased confidence and clinical decision-making ability in CT protocols
Preparing for and passing the CT exam deepens protocol knowledge, which enhances the technologist's confidence and quality of clinical decisions.
Question 100: For a trauma CT protocol of the chest, which contrast phase is typically acquired?
- Portal venous phase (Correct answer)
- Arterial phase only
- Delayed phase only
- Non-contrast only
Correct answer: Portal venous phase
The portal venous phase (~60โ70 seconds post-injection) provides optimal parenchymal enhancement to detect solid organ injuries in chest trauma.
Question 101: Multiplanar reformation (MPR) in CT refers to:
- Generating 3D surface models from volumetric data
- Subtracting pre-contrast from post-contrast images
- Applying color to CT images based on Hounsfield units
- Reconstructing axial images into coronal, sagittal, or oblique planes (Correct answer)
Correct answer: Reconstructing axial images into coronal, sagittal, or oblique planes
MPR uses the volumetric CT dataset to create reformatted images in any anatomical plane without additional radiation exposure to the patient.
Question 102: What documentation does an ARRT candidate typically need to submit to verify clinical competency in CT?
- Competency verification signed by a supervising radiologist or qualified technologist (Correct answer)
- A letter from the state radiology board
- ACR accreditation certificate of the facility
- Employer payroll records
Correct answer: Competency verification signed by a supervising radiologist or qualified technologist
Clinical competency must be verified by a supervising qualified professional who can attest that the candidate performed required procedures.
Question 103: Partial volume averaging artifact in CT is BEST minimized by:
- Using thinner slice collimation (Correct answer)
- Decreasing the tube current
- Increasing the reconstruction matrix
- Using a smoother reconstruction kernel
Correct answer: Using thinner slice collimation
Thinner slices reduce the z-axis extent of each voxel, decreasing the chance that multiple tissue types are averaged into a single voxel.
Question 104: In CT, 'DLP' (dose-length product) is calculated as:
- CTDIvol ร scan length (Correct answer)
- SSDE ร patient weight
- mAs ร kVp ร scan length
- CTDIw ร pitch
Correct answer: CTDIvol ร scan length
DLP = CTDIvol ร scan length (cm); it estimates the total energy deposited in the patient and is used to calculate effective dose.
Question 105: When a CT abdomen protocol specifies 'nephrographic phase,' scanning typically occurs at what delay after IV contrast injection?
- 80โ120 seconds (Correct answer)
- 5โ10 minutes
- 30โ45 seconds
- 15โ25 seconds
Correct answer: 80โ120 seconds
The nephrographic phase occurs at approximately 80โ120 seconds post-injection when both cortex and medulla enhance uniformly, optimizing renal parenchymal visualization.
Question 106: Quantum (photon) noise in CT images is most visible under which conditions?
- High kVp and wide window
- Fast pitch and narrow FOV
- High mAs and thin slices
- Low mAs or large patient size (Correct answer)
Correct answer: Low mAs or large patient size
Quantum noise increases when fewer photons reach the detectors, which occurs with low mAs settings or when X-rays are attenuated by a large patient.
Question 107: How many continuing education (CE) credits are required for recertification in ARRT CT?
- 12 CE credits
- 20 CE credits
- 40 CE credits
- 24 CE credits (Correct answer)
Correct answer: 24 CE credits
To maintain ARRT CT certification, technologists must complete a specific number of continuing education (CE) credits within each two-year renewal period. The requirement is 24 CE credits, which helps ensure that certified professionals stay updated with advancements and best practices in the field of computed tomography.
Question 108: Under ARRT's Continuing Qualifications Requirements (CQR), what must credential holders demonstrate?
- Ongoing competency through self-assessment and structured activities related to their discipline (Correct answer)
- Employer attestation of satisfactory job performance
- A passing score on a repeat certification exam every 10 years
- Completion of a new clinical rotation every 10 years
Correct answer: Ongoing competency through self-assessment and structured activities related to their discipline
CQR requires credential holders to complete self-assessment and structured CE activities demonstrating continued competency in their specialty.
Question 109: Which scan parameter change will REDUCE patient dose while keeping all other factors constant?
- Decreasing pitch from 1.5 to 0.75
- Increasing mAs from 200 to 300
- Decreasing scan length from 40 cm to 30 cm (Correct answer)
- Increasing rotation time from 0.5 s to 1.0 s
Correct answer: Decreasing scan length from 40 cm to 30 cm
Reducing scan length directly reduces the total volume irradiated and therefore lowers DLP and patient dose.
Question 110: What is a nosocomial infection?
- A genetic condition
- A respiratory infection
- A childhood disease
- An infection acquired in a healthcare facility (Correct answer)
Correct answer: An infection acquired in a healthcare facility
Nosocomial (healthcare-associated) infections are acquired during the course of receiving medical treatment in a healthcare facility, not present at admission.
Question 111: What is the primary purpose of performing a daily air calibration (warm-up scan) on a CT scanner?
- To verify gantry tilt accuracy
- To measure patient dose output
- To calibrate detector channels and normalize dark current (Correct answer)
- To test the table weight limit
Correct answer: To calibrate detector channels and normalize dark current
The daily air calibration normalizes detector channel responses and corrects for dark current drift, maintaining uniform image quality.
Question 112: How does ARRT define 'structured education' for CT post-primary eligibility?
- Any on-the-job training logged by the supervisor
- Formal coursework covering specific CT content areas as defined by ARRT (Correct answer)
- Self-study using any radiology textbook
- Attendance at a single CT conference or symposium
Correct answer: Formal coursework covering specific CT content areas as defined by ARRT
ARRT requires formal coursework in specific CT content areas as part of its structured education requirement for post-primary eligibility.
Question 113: In CT, the modulation transfer function (MTF) is used to characterize:
- Contrast resolution at different tissue densities
- Spatial frequency response and limiting spatial resolution (Correct answer)
- Patient dose efficiency
- Detector quantum efficiency
Correct answer: Spatial frequency response and limiting spatial resolution
The MTF describes how well the CT system transfers spatial frequencies from object to image, defining the system's spatial resolution capability.
Question 114: What happens to a technologist's post-primary CT certification if their primary ARRT registration lapses?
- The CT certification also lapses because it depends on primary registration status (Correct answer)
- The CT certification remains active independently
- Only the primary registration lapses; post-primary certifications are unaffected
- The CT certification converts to an inactive status automatically
Correct answer: The CT certification also lapses because it depends on primary registration status
Post-primary certifications such as CT are dependent on an active primary ARRT registration; if the primary lapses, so does the post-primary certification.
Question 115: Which window setting is most appropriate for evaluating pulmonary nodules in the lung parenchyma?
- Window width ~400 HU, window level ~40 HU
- Window width ~3000 HU, window level ~300 HU
- Window width ~1500 HU, window level ~-600 HU (Correct answer)
- Window width ~200 HU, window level ~80 HU
Correct answer: Window width ~1500 HU, window level ~-600 HU
Lung windows use a wide width (~1500 HU) and negative level (~-600 HU) to display the full range of lung attenuation from air to soft tissue.
Question 116: What type of artifact appears as bright or dark streaks radiating from high-density objects like metal implants in CT images?
- Motion artifact
- Partial volume artifact
- Ring artifact
- Beam hardening artifact (Correct answer)
Correct answer: Beam hardening artifact
Beam hardening artifacts appear as streaks or dark bands radiating from dense metallic objects because lower-energy photons are preferentially absorbed.
Question 117: The ARRT Standards of Ethics is incorporated into the CT certification process primarily to:
- Ensure candidates demonstrate professional integrity and moral character (Correct answer)
- Verify candidates' financial standing
- Confirm candidates' insurance coverage
- Assess candidates' academic GPA
Correct answer: Ensure candidates demonstrate professional integrity and moral character
The Standards of Ethics screening ensures that only individuals with demonstrated professional integrity are certified.
Question 118: Curved planar reformation (CPR) in CT is most useful for:
- Creating color-coded perfusion maps
- Straightening and displaying tortuous structures such as vessels or the spine along their entire length (Correct answer)
- Subtracting bone from CT angiography images
- Generating endoscopic views of hollow organs
Correct answer: Straightening and displaying tortuous structures such as vessels or the spine along their entire length
CPR follows a user-defined curved path through the volume dataset to display a tortuous structure in a single unfolded plane, useful for coronary arteries or the aorta.
Question 119: A radiologic technologist notices that CT images of the liver appear uniformly noisy despite using standard mAs. The MOST appropriate first corrective action is:
- Reduce the reconstruction FOV by 50%
- Verify that the correct reconstruction kernel and algorithm are applied (Correct answer)
- Double the mAs for the repeat scan immediately
- Switch to a narrower window width for display
Correct answer: Verify that the correct reconstruction kernel and algorithm are applied
Verifying protocol settings (kernel, algorithm, slice thickness) first ensures the source of apparent noise is identified before unnecessarily increasing dose.
Question 120: CT window width (WW) setting controls which aspect of image display?
- The spatial resolution of the image
- The range of Hounsfield units displayed as the full gray scale from black to white (Correct answer)
- The center Hounsfield unit of the gray scale
- The overall brightness of the image
Correct answer: The range of Hounsfield units displayed as the full gray scale from black to white
Window width determines the range of CT numbers (HU) mapped to the grayscale; a narrow window increases contrast but limits the HU range displayed.
Question 121: A 55-year-old patient develops generalized urticaria approximately 5 minutes after IV contrast injection. This reaction is best classified as:
- A delayed hypersensitivity reaction
- A physiologic reaction due to contrast osmolality
- A severe anaphylactic reaction requiring epinephrine
- A mild acute allergic-like (anaphylactoid) reaction (Correct answer)
Correct answer: A mild acute allergic-like (anaphylactoid) reaction
Generalized urticaria without systemic involvement (no bronchospasm or hypotension) represents a mild acute allergic-like reaction, typically treated with antihistamines.
Question 122: Which of these statements is true about eligibility for ARRT CT certification?
- Clinical competencies must be completed after passing the CT exam.
- Holding a state radiography license is enough to apply for certification.
- Applicants must hold an existing ARRT certification in an eligible primary pathway discipline. (Correct answer)
- Only professionals with a master's degree can apply for CT certification.
Correct answer: Applicants must hold an existing ARRT certification in an eligible primary pathway discipline.
ARRT CT certification is considered a post-primary certification, meaning it builds upon a foundational credential. Therefore, a prerequisite for applying is holding an active ARRT certification in a primary pathway discipline such as radiography, nuclear medicine technology, or radiation therapy. This ensures applicants have a core understanding of medical imaging principles.
Question 123: The Hounsfield unit (HU) value of pure water is:
- +100
- -1000
- 0 (Correct answer)
- +1000
Correct answer: 0
By definition, pure water is assigned an HU value of 0 on the Hounsfield scale used in CT imaging.
Question 124: The windmill artifact in multislice CT helical acquisitions is MOST pronounced when:
- High kVp is used with thin collimation
- Small FOV is selected with fine matrix
- Low mAs is used with a smooth kernel
- High pitch values are combined with thick slice reconstruction (Correct answer)
Correct answer: High pitch values are combined with thick slice reconstruction
Windmill artifact stems from undersampling in the z-direction; it is most visible with high pitch (sparse data) and thick reconstructions that exaggerate interpolation errors.
Question 125: The 'cupping artifact' in CT, where the center of a uniform object appears less dense than its periphery, is a manifestation of which phenomenon?
- Quantum noise
- Partial volume averaging
- Beam hardening (Correct answer)
- Aliasing
Correct answer: Beam hardening
Cupping artifact is a form of beam hardening where the edges of the object appear brighter because the beam hardens less traveling a shorter path length.
Question 126: In CT quality control documentation, what is the purpose of establishing 'action limits' for QC measurements?
- To establish the contrast media injection rate limits
- To determine the minimum number of QC tests per week
- To set thresholds that, when exceeded, require investigation and corrective action before clinical use (Correct answer)
- To define the maximum patient dose per study
Correct answer: To set thresholds that, when exceeded, require investigation and corrective action before clinical use
Action limits define tolerance thresholds for QC parameters; if a measurement falls outside these limits, the scanner must be taken out of service for investigation and repair.
Question 127: During a multi-phase CT liver protocol (non-contrast, arterial, portal venous, delayed), which action BEST reduces cumulative patient dose?
- Increase slice thickness per phase to reduce total acquisitions
- Use the maximum mAs for all phases to guarantee image quality
- Eliminate phases not essential for the clinical indication and use dose modulation for each phase (Correct answer)
- Increase kVp for each phase to reduce noise
Correct answer: Eliminate phases not essential for the clinical indication and use dose modulation for each phase
Eliminating unnecessary scan phases and applying tube current modulation to each remaining phase are the most effective strategies to reduce cumulative multi-phase CT dose.
Question 128: Iodinated contrast media produces vascular enhancement in CT primarily because iodine:
- Emits positrons that scatter X-rays
- Has a high atomic number that strongly attenuates X-rays (Correct answer)
- Reduces blood viscosity, increasing flow speed
- Increases the paramagnetic properties of blood
Correct answer: Has a high atomic number that strongly attenuates X-rays
Iodine (atomic number 53) has a high atomic number that dramatically increases X-ray attenuation in blood vessels and tissues, creating contrast enhancement on CT.
Question 129: Under ARRT policy, which of the following represents a 'primary pathway' to CT certification?
- Holding an ARRT credential in a related discipline and meeting CT requirements (Correct answer)
- Passing a state licensing exam only
- Graduating from any 4-year college program
- Completing 40 hours of online CT training
Correct answer: Holding an ARRT credential in a related discipline and meeting CT requirements
The primary pathway requires holding an ARRT credential in a related radiologic science discipline and fulfilling CT-specific education and clinical requirements.
Question 130: Which body administers the ARRT CT certification examination at testing centers?
- ACR regional offices
- JRCERT-affiliated schools
- Prometric (Correct answer)
- ARRT staff at ARRT headquarters
Correct answer: Prometric
ARRT partners with Prometric to deliver its certification examinations at testing centers nationwide.
Question 131: A 'blooming artifact' in CT most commonly results from:
- Incorrect HU calibration of the scanner
- Patient motion during acquisition
- Undersampling of high-frequency data
- High-density metallic objects causing overestimation of structure size (Correct answer)
Correct answer: High-density metallic objects causing overestimation of structure size
Blooming occurs when high-attenuation objects like metals or calcifications appear larger than their true size due to beam hardening and partial volume effects.
Question 132: When comparing filtered back projection (FBP) to model-based iterative reconstruction (MBIR) at matched noise levels, MBIR typically demonstrates:
- Higher spatial resolution with fewer artifacts at lower dose (Correct answer)
- Lower spatial resolution but equivalent noise
- Longer reconstruction times with no image quality advantage
- Equivalent resolution but increased beam hardening artifacts
Correct answer: Higher spatial resolution with fewer artifacts at lower dose
MBIR models the entire imaging chain including optics and statistics, achieving better resolution and artifact suppression at lower dose than FBP.
Question 133: Which entity must sponsor a continuing education activity for it to count toward ARRT CT recertification?
- The technologist's employing hospital
- Any national radiology organization
- The American College of Radiology only
- An ARRT-approved CE sponsor (Correct answer)
Correct answer: An ARRT-approved CE sponsor
ARRT only accepts Category A CE credits from activities provided by ARRT-approved sponsors, ensuring quality and relevance.
Question 134: A ring or band artifact centered on the image is most likely caused by a malfunction of which CT component?
- Collimator
- Gantry motor
- A single detector element (Correct answer)
- X-ray tube
Correct answer: A single detector element
Ring artifacts result from a miscalibrated or malfunctioning detector element producing a circular artifact at a fixed radius from the isocenter.
Question 135: On CT urography, a urothelial carcinoma of the ureter would most likely appear as:
- Ureteral wall calcification
- Periureteral fat stranding only
- Smooth fusiform dilation of the ureter
- Intraluminal filling defect with upstream hydronephrosis (Correct answer)
Correct answer: Intraluminal filling defect with upstream hydronephrosis
Urothelial carcinoma typically presents as an intraluminal filling defect causing partial or complete obstruction with upstream hydronephrosis.
Question 136: Which technique is most commonly used to reduce metal artifact in CT imaging of patients with hip prostheses?
- Decreasing kVp
- Increasing slice thickness
- Using a smaller FOV
- Metal artifact reduction (MAR) software (Correct answer)
Correct answer: Metal artifact reduction (MAR) software
Metal artifact reduction (MAR) algorithms replace corrupted projection data near metal with interpolated data, significantly reducing streaking artifacts.
Question 137: Which reconstruction kernel (filter) should be chosen to minimize noise when imaging soft tissue structures in the abdomen?
- Lung kernel
- Smooth or standard soft tissue kernel (Correct answer)
- Bone or edge-enhancing kernel
- Ultra-high resolution kernel
Correct answer: Smooth or standard soft tissue kernel
Soft tissue kernels apply low-pass filtering that smooths the image and reduces noise, which is appropriate for abdominal soft tissue evaluation.
Question 138: What is the primary purpose of the CT dose index (CTDI)?
- To determine scatter radiation levels in the control room
- To calculate the effective dose to the technologist
- To measure patient absorbed dose in a single organ
- To characterize radiation output of a CT scanner independent of patient size (Correct answer)
Correct answer: To characterize radiation output of a CT scanner independent of patient size
CTDI characterizes the radiation output of a CT scanner and allows standardized comparison between scanners and protocols.
Question 139: How often must an ARRT CT certification be renewed?
- Every 2 years (Correct answer)
- Every 10 years
- Every 5 years
- Every 3 years
Correct answer: Every 2 years
ARRT CT certification, like most ARRT credentials, requires regular renewal to ensure technologists maintain current knowledge and skills. Certified professionals must renew their certification every two years. This biennial renewal process typically involves meeting continuing education requirements.
Question 140: Which scan phase best demonstrates hepatic metastases that are hypervascular?
- Portal venous phase
- Hepatic arterial phase (Correct answer)
- Delayed phase
- Non-contrast phase
Correct answer: Hepatic arterial phase
Hypervascular metastases enhance avidly during the hepatic arterial phase when liver parenchyma enhancement is low, maximizing lesion-to-liver contrast.
Question 141: Respiratory motion artifacts on chest CT can best be minimized by:
- Increasing slice thickness
- Increasing kVp
- Widening the display window
- Using breath-hold technique during acquisition (Correct answer)
Correct answer: Using breath-hold technique during acquisition
Instructing the patient to suspend respiration during CT acquisition eliminates breathing motion, preventing blurring and step artifacts in the chest.
Question 142: Which CT finding helps differentiate a retroperitoneal hematoma from a retroperitoneal abscess?
- Hyperdense content on non-contrast CT (Correct answer)
- Displacement of adjacent organs
- Presence of gas bubbles within the collection
- Location posterior to the peritoneum
Correct answer: Hyperdense content on non-contrast CT
Acute hematomas appear hyperdense (50โ70 HU) on non-contrast CT due to clotted blood, distinguishing them from fluid collections.
Question 143: On CT of the head, lenticular (biconvex) hyperdensity is identified adjacent to the temporal bone. What is the most likely cause?
- Bridging vein rupture causing subdural hematoma
- Hypertensive hemorrhage
- Berry aneurysm rupture
- Middle meningeal artery rupture causing epidural hematoma (Correct answer)
Correct answer: Middle meningeal artery rupture causing epidural hematoma
Epidural hematomas result from middle meningeal artery injury and form a biconvex hyperdense collection limited by dural attachments at sutures.
Question 144: When performing a venipuncture for contrast administration, the needle bevel should be oriented:
- At a 90-degree angle to the skin
- Parallel to the skin surface, bevel sideways
- Facing down toward the vein wall
- Facing up (bevel up) (Correct answer)
Correct answer: Facing up (bevel up)
The bevel-up orientation allows the needle to enter the vein smoothly and reduces the risk of piercing the posterior vein wall.
Question 145: What is the fire triangle?
- Heat, fuel, and oxygen โ the three elements needed for fire (Correct answer)
- Three fire escape routes
- Three types of fire extinguishers
- Three fire departments
Correct answer: Heat, fuel, and oxygen โ the three elements needed for fire
The fire triangle illustrates the three elements required for combustion: heat (ignition source), fuel (combustible material), and oxygen. Removing any one element extinguishes the fire.
Question 146: An ARRT credential holder moves to a state that requires separate state licensure. Which of the following is correct?
- State licensure is separate from ARRT certification and must be obtained independently (Correct answer)
- ARRT certification automatically fulfills state licensure requirements in all states
- JRCERT issues the state license upon request
- The technologist must retake the ARRT exam for state purposes
Correct answer: State licensure is separate from ARRT certification and must be obtained independently
ARRT certification and state licensure are distinct; technologists must comply with individual state requirements separately.
Question 147: If a CT technologist allows their ARRT registration to lapse, what is required before they can reinstate it?
- Complete the required CE credits and pay applicable fees (Correct answer)
- Retake the full certification examination
- Submit a written appeal to the ARRT board
- Pay a late fee only
Correct answer: Complete the required CE credits and pay applicable fees
Reinstatement of a lapsed ARRT registration requires fulfilling outstanding CE requirements and paying any applicable reinstatement fees.
Question 148: Which of the following describes the location of the zona incerta on axial CT brain images?
- A white matter tract connecting the thalamus to the frontal lobe
- A sulcus separating the caudate from the putamen
- A thin band of gray matter between the lenticular fasciculus and the thalamic fasciculus in the subthalamus (Correct answer)
- Gray matter located in the posterior limb of the internal capsule
Correct answer: A thin band of gray matter between the lenticular fasciculus and the thalamic fasciculus in the subthalamus
The zona incerta is a subthalamic gray matter band situated between the lenticular and thalamic fasciculi.
Question 149: A CT technologist is audited by ARRT and cannot produce records for completed CE activities. What is the most likely consequence?
- They are required to repeat the certification exam
- ARRT will contact the CE sponsors on their behalf
- A formal written warning is issued
- Their CE credits may be disallowed and registration revoked (Correct answer)
Correct answer: Their CE credits may be disallowed and registration revoked
During an audit, failure to document CE activities can result in disallowance of credits and potential revocation of registration.
Question 150: Size-specific dose estimate (SSDE) improves upon CTDIvol by:
- Measuring dose in air rather than in phantom
- Correcting for beam hardening errors
- Accounting for scan length
- Incorporating patient size to provide a more accurate dose estimate for individual patients (Correct answer)
Correct answer: Incorporating patient size to provide a more accurate dose estimate for individual patients
SSDE applies a conversion factor based on patient diameter or water equivalent diameter to CTDIvol, yielding a more patient-specific absorbed dose estimate.
Question 151: On axial CT of the head at the level of the fourth ventricle, which structure is immediately posterior to the fourth ventricle?
- Cerebellum (vermis) (Correct answer)
- Choroid plexus
- Medulla oblongata
- Pons
Correct answer: Cerebellum (vermis)
The cerebellar vermis forms the posterior wall of the fourth ventricle on axial CT images.
Question 152: Quantum mottle in CT images is primarily caused by:
- Detector calibration errors
- High kVp beam hardening
- An insufficient number of detected photons (Correct answer)
- Excessive table speed
Correct answer: An insufficient number of detected photons
Quantum mottle (noise) occurs when too few photons reach the detector, causing statistical fluctuations that appear as grainy image texture.
Question 153: What is the function of red blood cells?
- To produce hormones
- To clot blood
- To fight infection
- To transport oxygen from lungs to tissues and CO2 back (Correct answer)
Correct answer: To transport oxygen from lungs to tissues and CO2 back
Red blood cells (erythrocytes) contain hemoglobin that binds oxygen in the lungs and delivers it to tissues, then carries carbon dioxide back for exhalation.
Question 154: A technologist holds ARRT primary certification in Radiography and a post-primary in CT. How many total CE credits are required per cycle?
- 48 total โ 24 for each credential separately
- 24 total, shared across both credentials (Correct answer)
- 36 total โ 24 for primary plus 12 for post-primary
- 24 total, with at least 6 specific to CT
Correct answer: 24 total, shared across both credentials
ARRT allows the same 24 Category A CE credits to satisfy renewal requirements for both the primary and post-primary certifications simultaneously.
Question 155: Automatic tube current modulation (ATCM) in CT primarily aims to:
- Maintain consistent image noise while minimizing patient dose (Correct answer)
- Eliminate motion artifacts in cardiac imaging
- Maximize image spatial resolution for all body regions
- Improve temporal resolution in dynamic studies
Correct answer: Maintain consistent image noise while minimizing patient dose
ATCM adjusts mA based on patient attenuation in real time, delivering higher current through thicker/denser regions to maintain uniform noise and reducing dose elsewhere.
Question 156: What is the purpose of an emergency action plan?
- To establish procedures for responding to various emergencies (Correct answer)
- To schedule daily activities
- To assign parking spaces
- To manage budgets
Correct answer: To establish procedures for responding to various emergencies
Emergency action plans outline specific procedures for different emergency scenarios, ensuring organized, efficient response that protects personnel.
Question 157: On axial CT of the neck, the hypopharynx is best visualized at which vertebral level?
- C7-T1
- C3-C4
- C4-C6 (Correct answer)
- C1-C2
Correct answer: C4-C6
The hypopharynx extends from the level of the hyoid bone (C3) to the cricopharyngeus muscle (C6), and is best visualized on CT at C4-C6.
Question 158: The ARRT CT post-primary examination content specifications are reviewed and updated approximately every:
- 10 years
- Every certification cycle (2 years)
- 5 years (Correct answer)
- 1 year
Correct answer: 5 years
ARRT reviews and updates examination content specifications on approximately a five-year cycle through its practice analysis process.
Question 159: Which reconstruction kernel (filter) choice produces the HIGHEST spatial resolution but MOST noise in CT?
- Soft/smooth kernel
- Standard kernel
- Lung kernel
- Sharp/edge-enhancing kernel (Correct answer)
Correct answer: Sharp/edge-enhancing kernel
Sharp or bone kernels enhance high-frequency data to improve edge detail but amplify noise, making them high-resolution but noisy.
Question 160: On axial CT of the orbit, which extraocular muscle is located at the medial wall of the orbit?
- Medial rectus (Correct answer)
- Superior rectus
- Inferior oblique
- Superior oblique
Correct answer: Medial rectus
The medial rectus muscle runs along the medial orbital wall and is the most commonly enlarged muscle in thyroid eye disease.
Question 161: Which of the following CE activities would NOT qualify toward ARRT renewal requirements?
- Publishing a peer-reviewed article in a radiology journal
- Completing a vendor-sponsored equipment demonstration with no educational content (Correct answer)
- Attending an ASRT-approved radiology continuing education course
- Serving as a JRCERT program reviewer
Correct answer: Completing a vendor-sponsored equipment demonstration with no educational content
Vendor demonstrations without structured educational content do not meet ARRT's CE requirements; activities must have identifiable learning objectives.
Question 162: The pitch value in helical CT is defined as:
- Gantry rotation speed divided by table speed
- kVp divided by mA
- Slice thickness divided by detector row width
- Table travel per rotation divided by total beam collimation width (Correct answer)
Correct answer: Table travel per rotation divided by total beam collimation width
Pitch = table distance traveled per 360ยฐ rotation รท total collimated beam width, and values >1 indicate gaps in data coverage.
Question 163: When evaluating a CT image for streak artifacts emanating from a hip prosthesis, the BEST corrective technique is:
- Decreasing the mAs by 50%
- Increasing the kVp to 140
- Metal artifact reduction (MAR) reconstruction algorithm (Correct answer)
- Widening the reconstruction FOV
Correct answer: Metal artifact reduction (MAR) reconstruction algorithm
Metal artifact reduction algorithms use iterative or sinogram-based techniques to model and subtract metal-induced streaks from the image.
Question 164: A technologist working in a trauma center wants to advance to a CT lead position. Which prerequisite is most commonly required by employers?
- Completion of a vendor-specific scanner training course
- ARRT CT post-primary certification (Correct answer)
- A master's degree in radiologic science
- Five years of emergency department experience only
Correct answer: ARRT CT post-primary certification
ARRT CT certification is the most universally recognized and commonly required credential for CT lead or supervisory positions.
Question 165: The 'partial volume effect' artifact in CT occurs when:
- The detector cells are too large for the FOV selected
- The patient moves during the scan
- The beam is too narrow to penetrate dense bone
- A voxel contains two or more tissues of different attenuation, producing an averaged HU value (Correct answer)
Correct answer: A voxel contains two or more tissues of different attenuation, producing an averaged HU value
Partial volume averaging occurs when a single voxel spans structures of different densities, and the CT number represents the average rather than any single material.
Question 166: In a CT perfusion study of the brain, which parameter measures the volume of blood in a given unit of brain tissue?
- Cerebral blood volume (CBV) (Correct answer)
- Cerebral blood flow (CBF)
- Mean transit time (MTT)
- Time to peak (TTP)
Correct answer: Cerebral blood volume (CBV)
Cerebral blood volume (CBV) represents the total volume of blood within a defined brain tissue volume, measured in mL/100g.
Question 167: Which phenomenon explains why CT numbers for bone may appear elevated at the center of a thick bony structure compared to peripheral bone?
- Partial volume effect
- Beam hardening cupping artifact (Correct answer)
- Undersampling artifact
- Ring artifact
Correct answer: Beam hardening cupping artifact
Beam hardening causes preferential absorption of lower-energy photons; more hardening occurs centrally, leading to erroneously high CT numbers at bone edges and low values centrally (cupping).
Question 168: When performing a CT pulmonary angiography (CTPA), which scan direction is preferred?
- Either direction equally
- Caudal to cranial (Correct answer)
- Cranial to caudal
- Bidirectional
Correct answer: Caudal to cranial
Caudal-to-cranial scanning in CTPA ensures the densest contrast bolus reaches the pulmonary arteries during image acquisition.
Question 169: Which career pathway is most directly opened by holding ARRT CT certification?
- Radiology billing and coding specialist
- Lead CT technologist or CT supervisor (Correct answer)
- Radiation oncology physician assistant
- Nuclear medicine physician
Correct answer: Lead CT technologist or CT supervisor
CT certification establishes the specialized credential often required for leadership roles such as lead CT tech or CT department supervisor.
Question 170: The Hounsfield unit (HU) value of pure water is defined as:
- 0 HU (Correct answer)
- +500 HU
- +1000 HU
- -1000 HU
Correct answer: 0 HU
The CT number scale defines water as 0 HU and air as โ1000 HU, with other tissues placed relative to these references.
Question 171: What is the purpose of contrast media in CT scans?
- To reduce radiation dose
- To speed up the scan
- To enhance the visibility of specific structures and pathology (Correct answer)
- To make the patient comfortable
Correct answer: To enhance the visibility of specific structures and pathology
Contrast media (dye) enhances the visibility of blood vessels, organs, and abnormalities by changing how X-rays interact with specific tissues.
Question 172: A patient undergoing a radiographic exam becomes unresponsive and pulseless. The technologist should FIRST:
- Place the patient in recovery position and observe
- Administer oxygen via nasal cannula
- Begin chest compressions immediately while calling for help (Correct answer)
- Activate the emergency response system (call code)
Correct answer: Begin chest compressions immediately while calling for help
According to current AHA guidelines, high-quality chest compressions should begin immediately while simultaneously calling for emergency help.
Question 173: Within what timeframe must newly certified CT technologists complete their first renewal cycle?
- Three years from certification date
- One year from certification date
- When their primary registration expires (Correct answer)
- Two years from certification date
Correct answer: When their primary registration expires
Post-primary certification renewal is typically aligned with the technologist's primary registration renewal date, not a separate independent cycle.
Question 174: Which of the following best describes an out-of-field artifact in CT?
- Blurring from respiratory motion
- Streaking caused by anatomy extending beyond the scan FOV (Correct answer)
- Ring caused by detector failure
- Noise from low mAs
Correct answer: Streaking caused by anatomy extending beyond the scan FOV
Out-of-field artifacts occur when part of the patient's anatomy lies outside the calibrated scan FOV, causing truncation of projection data and bright peripheral streaks.
Question 175: Which organization is primarily responsible for accrediting radiologic technology programs in the United States?
- ARRT
- ACR-AAPM
- ACR
- JRCERT (Correct answer)
Correct answer: JRCERT
The Joint Review Committee on Education in Radiologic Technology (JRCERT) is the primary accrediting body for radiologic technology programs.
Question 176: What is the primary purpose of selecting a small reconstruction FOV (field of view) during CT image reconstruction?
- To increase the pixel size for better soft tissue contrast
- To improve spatial resolution by sampling more detail per pixel (Correct answer)
- To reduce patient dose
- To decrease image noise
Correct answer: To improve spatial resolution by sampling more detail per pixel
A smaller reconstruction FOV divides the imaged area into the same matrix of pixels, resulting in smaller pixel size and therefore higher spatial resolution of the region of interest.
Question 177: A patient taking metformin for type 2 diabetes is receiving IV iodinated contrast. Per ACR guidelines, when should metformin be withheld after contrast administration in a patient with normal renal function?
- Withhold for 24 hours before and after the exam
- Withhold only if the patient has an allergic reaction
- Withhold for 72 hours regardless of renal function
- It does not need to be withheld in patients with normal renal function (Correct answer)
Correct answer: It does not need to be withheld in patients with normal renal function
ACR guidelines state that patients with normal renal function (eGFR โฅ 30) receiving IV contrast do not need to withhold metformin.
Question 178: When using a mechanical patient lift (Hoyer lift), the sling should be placed under the patient:
- Correctly positioned before activating the lift, with all attachment points secured (Correct answer)
- After the patient is partially elevated to assess comfort
- Only when the patient is completely unconscious
- Only under the torso, leaving the legs unsupported
Correct answer: Correctly positioned before activating the lift, with all attachment points secured
All sling attachment points must be secured and the sling properly positioned before activating the lift to prevent the patient from falling.
Question 179: What is the minimum number of Category A CE credits that must be completed in the final year of a 2-year ARRT renewal cycle?
- 0 โ credits can all be earned in one year (Correct answer)
- All 24 credits must be earned evenly each year
- 6 credits minimum per year are required
- 12 credits minimum in the second year
Correct answer: 0 โ credits can all be earned in one year
ARRT does not require credits to be distributed evenly across both years; all 24 Category A credits can technically be earned at any point during the 2-year cycle.
Question 180: On axial CT at the level of the pelvis, the external iliac artery is located relative to the external iliac vein in which position?
- Medial to the vein
- Lateral to the vein
- Anterior and medial to the vein (Correct answer)
- Posterior to the vein
Correct answer: Anterior and medial to the vein
The external iliac artery lies anteromedial to the external iliac vein along the pelvic brim.
Question 181: For a radiologic technologist considering subspecialty practice, which statement about ARRT CT certification scope is most accurate?
- CT certification validates technical performance skills, not image interpretation or diagnosis (Correct answer)
- CT certification covers interventional radiology procedures as well
- CT certification qualifies technologists to independently interpret CT scans
- CT certification is equivalent to a fellowship in CT radiology
Correct answer: CT certification validates technical performance skills, not image interpretation or diagnosis
ARRT CT certification validates technical performance and patient care competencies; image interpretation and diagnosis remain within the radiologist's scope.
Question 182: Which section of the ARRT application requires disclosure of prior criminal history and ethics violations?
- Structured education section
- Reference section
- Ethics section (Correct answer)
- Clinical competency section
Correct answer: Ethics section
The ethics section of the ARRT application requires applicants to disclose criminal history, professional disciplinary actions, and other relevant ethical matters.
Question 183: Extravasation of iodinated contrast media into surrounding tissue most commonly occurs due to:
- Needle or catheter dislodgement from the vein during power injection (Correct answer)
- Allergic reaction to the contrast agent
- Patient movement during injection
- Contrast being injected too slowly
Correct answer: Needle or catheter dislodgement from the vein during power injection
Extravasation typically results from needle or catheter displacement from the vessel lumen, allowing contrast to leak into the interstitial tissue.
Question 184: An ARRT-certified CT technologist moves to a state that also requires state licensure for CT practice. Which statement is true?
- State licensure CE requirements always mirror ARRT requirements exactly
- ARRT certification replaces all state licensing requirements
- State licensure and ARRT certification are separate and both may be required (Correct answer)
- ARRT automatically notifies the state upon renewal
Correct answer: State licensure and ARRT certification are separate and both may be required
ARRT certification and state licensure are independent processes; meeting ARRT standards does not automatically satisfy state licensing requirements.
Question 185: The window level (WL) in CT display refers to:
- The center Hounsfield unit value of the displayed grayscale range (Correct answer)
- The minimum threshold for bone segmentation
- The reconstruction matrix size
- The total range of Hounsfield units shown
Correct answer: The center Hounsfield unit value of the displayed grayscale range
Window level sets the midpoint of the HU range being displayed, determining which tissue densities appear as medium gray on the monitor.
Question 186: On axial CT at the level of L4-L5, which structure is found anterior to the vertebral body?
- Inferior mesenteric artery origin
- Superior mesenteric artery origin
- Celiac axis
- Abdominal aortic bifurcation (Correct answer)
Correct answer: Abdominal aortic bifurcation
The abdominal aorta bifurcates into the common iliac arteries at approximately the L4 vertebral level.
Question 187: What is the first priority in any emergency situation?
- Write a report
- Ensure the safety of all personnel (Correct answer)
- Contact the media
- Save equipment
Correct answer: Ensure the safety of all personnel
In any emergency, the first priority is always the safety and well-being of all personnel. Equipment and materials can be replaced; lives cannot.
Question 188: What is the minimum passing score on the ARRT CT certification examination?
- 65 (scaled score)
- 70 (percent correct)
- 75 (scaled score) (Correct answer)
- 80 (percent correct)
Correct answer: 75 (scaled score)
ARRT uses a scaled scoring system and sets the minimum passing scaled score at 75.
Question 189: A CT pelvis shows a complex ovarian mass with solid components, calcifications, fat density, and hair-like structures. This is most consistent with:
- Mature cystic teratoma (dermoid cyst) (Correct answer)
- Serous cystadenocarcinoma
- Mucinous cystadenoma
- Endometrioma
Correct answer: Mature cystic teratoma (dermoid cyst)
Mature cystic teratomas contain fat, calcium, and soft tissue elements (including teeth or hair) from multiple germ cell layers.
Question 190: CT calcium scoring of the coronary arteries uses which post-processing method to quantify calcification?
- Volume rendering with opacity mapping
- MIP projection over the cardiac cycle
- Subtraction of non-contrast from contrast images
- Agatston scoring based on lesion area and peak Hounsfield unit density (Correct answer)
Correct answer: Agatston scoring based on lesion area and peak Hounsfield unit density
Agatston scoring multiplies the area of each calcified lesion by a density factor based on peak HU (1โ4 scale), then sums all lesions to yield the total calcium score.
Question 191: Which CT parameter most directly controls the amount of radiation dose delivered to the patient?
- kVp
- Reconstruction kernel
- Pitch
- mAs (Correct answer)
Correct answer: mAs
mAs (milliampere-seconds) directly determines the number of X-ray photons produced and is the primary controller of patient dose.
Question 192: Which of the following patient populations has the HIGHEST radiosensitivity?
- Adult males aged 40-60
- Pregnant women in the third trimester
- Elderly patients over 75
- Fetuses and children under 5 years of age (Correct answer)
Correct answer: Fetuses and children under 5 years of age
Fetuses and young children are most radiosensitive due to rapidly dividing cells and longer life expectancy over which stochastic effects can manifest.
Question 193: What is the window level and window width on CT images?
- Physical measurements of the CT scanner
- Settings that control the brightness and contrast of displayed images (Correct answer)
- Scan speed controls
- Patient positioning parameters
Correct answer: Settings that control the brightness and contrast of displayed images
Window level sets the center brightness (what HU appears as middle gray) and window width controls contrast range (how many HUs span from black to white).
Question 194: Which type of CT detector material is most commonly used in modern multi-detector CT (MDCT) systems due to its high conversion efficiency and fast decay time?
- Xenon gas ionization chambers
- Bismuth germanate (BGO) crystals
- Sodium iodide (NaI) crystal detectors
- Gadolinium oxysulfide (GOS) solid-state scintillators (Correct answer)
Correct answer: Gadolinium oxysulfide (GOS) solid-state scintillators
Modern MDCT scanners predominantly use solid-state scintillator detectors such as gadolinium oxysulfide because of their high X-ray absorption efficiency and rapid afterglow decay.
ARRT Computed Tomography (CT) Certification Examination
The ARRT CT certification exam assesses entry-level knowledge and cognitive skills required for computed tomography practice, covering patient care, radiation safety, image production, and CT imaging procedures across all major anatomical regions.
Exam Rules
- You can skip questions and return to them later
- Flag questions for review before submitting
- No feedback shown until you submit the entire exam
- Unanswered questions count as wrong โ answer everything
- 10 pretest questions are mixed in and don't affect your score
- Timer auto-submits when time runs out
- Your progress is auto-saved every 30 seconds