← All AFE Flashcard Decks

Facilities Management & Operations Flashcards

7 cards from real AFE practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Facilities Management & Operations flashcards as text
  1. Which Americans with Disabilities Act (ADA) requirement specifies the minimum clear floor space needed for a wheelchair to make a 180-degree turn?

    Answer: 60-inch diameter

    The ADA Standards for Accessible Design require a 60-inch (5-foot) diameter clear floor space for a wheelchair to complete a 180-degree turn.

  2. A facilities manager is analyzing Key Performance Indicators. What does 'PM compliance rate' measure?

    Answer: Ratio of preventive maintenance work orders completed on schedule vs. total planned

    PM compliance rate tracks the percentage of planned preventive maintenance tasks completed within the scheduled time window, indicating how well the PM program is being executed.

  3. In the context of building automation systems (BAS), what function does 'demand-controlled ventilation' (DCV) perform?

    Answer: It varies ventilation rates based on actual occupancy measured by CO2 sensors

    DCV uses CO2 sensors as a proxy for occupancy to automatically adjust outside air ventilation rates, reducing energy use in spaces with variable occupancy.

  4. What is the primary goal of the 'Plan-Do-Check-Act' (PDCA) cycle when applied to facilities management?

    Answer: To drive continuous improvement in FM processes and performance

    The PDCA cycle provides a structured framework for FM continuous improvement by planning changes, implementing them, measuring results, and adjusting based on findings.

  5. Under the Clean Air Act, which refrigerant phase-out regulation most directly impacts facilities managers maintaining HVAC systems?

    Answer: Section 608 regulations governing refrigerant handling and recovery

    EPA Section 608 requires certified technicians to recover refrigerants during servicing, prohibits venting, and mandates leak repairs, directly governing HVAC maintenance practices.

  6. When calculating the 'Facilities Condition Index' (FCI), a lower FCI value indicates what?

    Answer: Better facility condition with less deferred maintenance backlog

    FCI = Deferred Maintenance Cost ÷ Current Replacement Value; a lower FCI (closer to 0) indicates better condition, while an FCI above 0.10 typically signals poor condition.

  7. Which type of contract arrangement gives a facilities management service provider the greatest incentive to improve efficiency and reduce costs?

    Answer: Performance-based contract with gain-sharing

    Performance-based contracts with gain-sharing align provider incentives with client goals by sharing a portion of achieved savings, motivating continuous efficiency improvements.