NOCE Cheat Sheet 2026
The 30 highest-yield NOCE facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
200 questions
150 min time limit
70% to pass
- Using Prentice's rule, how much prism is induced when a patient looks 8mm below the optical center of a +3.00 D lens? → 2.4 prism diopters
- Which standard governs the occupational and educational personal eye protection requirements for safety eyewear? → ANSI Z87.1
- Which contact lens wearing schedule requires the most stringent patient education regarding infection risk? → Extended wear (overnight)
- A patient's frame is made of memory metal (beta-titanium or Flexon). What is the key advantage of this material for active patients? → It returns to its original shape after bending, reducing breakage
- Which combination of lens materials inherently blocks UV radiation up to 400nm without requiring an additional UV coating or treatment? → Polycarbonate and Trivex
- A patient's AR-coated lenses show a persistent greenish or purplish residual reflection. This is MOST likely due to: → The normal residual reflection color of AR coating design
- Which of the following correctly describes the function of the axis wheel on a manual lensometer? → It rotates the target to align the cylinder axis of the lens
- What does lag (or lens lag) describe in contact lens fitting assessment? → The movement of the lens in the opposite direction after an eye movement
- What is the resulting prescription when +1.75 -2.50 x 085 is transposed? → -0.75 +2.50 x 175
- Which type of multifocal lens design eliminates visible segment lines while providing a smooth progression of power? → Progressive addition lens
- Which lensometer target pattern indicates that a cylindrical correction is present in the lens being measured? → One set of mire lines clears at a different power than the other set
- According to the ANSI Z80.1-2020 tolerance standards, what is the allowable tolerance for sphere power for a prescription of -4.75 D? → ±0.13 D
- In contact lens prescribing, what is the recommended approach when there is a significant amount of residual astigmatism with a spherical soft lens? → Prescribe a toric soft contact lens to correct the residual cylinder
- OSHA standard 29 CFR 1910.133 requires employers to provide which type of eyewear to employees? → Appropriate eye and face protection for occupational hazards
- A reverse slab-off is used to compensate for vertical imbalance in a patient with anisometropia. On which lens is a reverse slab-off applied? → The lens with the most plus or least minus power in the vertical meridian.
- The Abbe number (V) is calculated as V = (nD − 1) / (nF − nC). This formula quantifies: → Chromatic dispersion — higher values mean less dispersion
- When a spectacle prescription exceeds ±4.00 D in sphere power, back vertex distance becomes clinically significant because: → Small changes in vertex distance produce meaningful changes in effective lens power
- A patient selects a frame with a very high base curve (e.g., 8 base). Which lens type is BEST suited for this frame? → Wrap-designed or atoric lenses corrected for the tilt
- Which anti-reflective coating layer is responsible for bonding the AR stack to the lens surface? → Adhesion layer
- Using the simplified sag formula s ≈ y²/(2r), what is the sag when y = 30 mm and r = 200 mm? → 2.25 mm
- When using a Burton lamp (UV lamp) to inspect contact lenses with fluorescein, a dark (black) area under a rigid contact lens indicates: → Bearing or touch between the lens and cornea
- Monocular PD for bifocal segment centration should be measured with the patient: → Looking straight ahead at distance fixation
- Light diverging from a point source located 50 cm away has a vergence of: → -2.00 D
- The image formed by a converging lens when the object is placed between the focal point and the lens is: → Virtual, erect, and magnified
- When using a lensometer to verify prism, the amount of prism is measured by: → How far the target mires are displaced from the center of the reticle in prism diopters
- Which layer of the cornea is responsible for pumping excess fluid out of the stroma to maintain its clarity? → Endothelium
- A patient is diagnosed with myopia. This refractive error is primarily caused by which anatomical variation? → The eyeball being too long, causing light to focus in front of the retina.
- Which of the following correctly describes the role of the 'seg height' measurement in a lined bifocal fitting? → The vertical distance from the lowest edge of the lens to the top of the bifocal segment
- Which federal agency primarily regulates the manufacture and labeling of prescription eyeglass lenses and frames as medical devices? → Food and Drug Administration (FDA)
- The ANSI Z80.1 standard specifies that for a single-vision distance lens with a power of -5.00 D, the maximum allowable cylinder power error is: → ±0.13 D
Turn these facts into recall:
Was this helpful?