HVAC Cheat Sheet 2026

The 30 highest-yield HVAC facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.

100 questions
120 min time limit
70.00% to pass
  1. In commercial HVAC design, what is the purpose of a smoke control system? To manage airflow during a fire to protect egress paths and aid firefighting
  2. What is the maximum fill level (by weight) for a recovery cylinder? 80%
  3. What is the purpose of vacuuming a mini-split system before charging? Both B and C — remove air/moisture and verify leak-free
  4. What troubleshooting method uses the process of elimination by testing components from 'most likely to least likely'? The probable-cause method
  5. What does a 'chilled water coil' use instead of direct refrigerant expansion? Cold water (typically 44-46°F) circulated from a central chiller
  6. What is the purpose of a disconnect switch near an outdoor HVAC unit? To provide a local means of de-energizing the unit for safe service work
  7. Which type of air handler configuration has the blower located downstream of the coil? Draw-through
  8. Commercial HVAC maintenance contracts differ from residential service agreements primarily in that commercial contracts typically include: More frequent scheduled maintenance visits and detailed performance reporting
  9. Which refrigerant has been the standard for new residential split systems since R-22 was phased out? R-410A
  10. A technician finds oil staining around a brazed refrigerant joint on a rooftop unit. What should be done before adding refrigerant? Repair the leak, pressure-test, evacuate, then recharge
  11. In a BAS, what does a PID controller stand for? Proportional-Integral-Derivative
  12. What is the primary purpose of an oil separator used during refrigerant recovery? To separate compressor oil from refrigerant before it enters the recovery cylinder
  13. What is the function of a 'passive' or 'system-dependent' recovery device? It uses the system's own compressor to push refrigerant into the recovery cylinder
  14. A technician recovers refrigerant into a cylinder that already contains a different refrigerant. What must happen to this cylinder? It must be labeled as mixed/contaminated and sent to a refrigerant reclaimer
  15. Which BAS sequence of operation step typically follows the morning warm-up mode? Occupied mode
  16. In a BAS, what is the purpose of the 'priority array' in BACnet commandable objects? Manage multiple competing commands to an output by assigning priority levels 1-16
  17. Which code or standard establishes minimum efficiency requirements for residential central air conditioners in the United States? DOE minimum efficiency standards (SEER ratings)
  18. A heat recovery ventilator (HRV) is used in residential buildings primarily to: Exchange stale indoor air for fresh outdoor air while recovering heat energy
  19. Which recovery method is fastest for recovering large amounts of liquid refrigerant? Liquid recovery first, then vapor
  20. What does 'ASHRAE 90.1' establish that BAS designers must follow? Energy efficiency standards including HVAC controls requirements for commercial buildings
  21. What is the most common cause of a clogged condensate drain line? Algae and biological growth in the drain line
  22. What is the purpose of a Variable Air Volume (VAV) box in a BAS-controlled system? To modulate airflow to individual zones to maintain zone temperature setpoints
  23. Which commercial HVAC system component is responsible for distributing conditioned air to specific zones based on thermostat demand? VAV terminal box
  24. What type of coil is used in an air handler for the heating mode in a heat pump system? The same evaporator coil, which acts as a condenser during heating mode
  25. What does 'superheat' refer to in the context of an evaporator coil? The temperature of refrigerant vapor above its saturation temperature
  26. What is the function of a 'hard-start kit' (potential relay and start capacitor) on an air handler? It is not used on air handlers — only on compressors
  27. What is the typical fin spacing (fins per inch) for a residential evaporator coil? 8-14 fins per inch
  28. What is the primary advantage of a two-stage or variable-speed gas furnace? Improved comfort and efficiency by operating at lower capacity most of the time
  29. Duct leakage testing is required by energy codes primarily in: New residential construction to verify duct system integrity
  30. What unit is used to measure the cooling capacity of HVAC equipment in the US? BTU/hr or tons