F-02 - Fireguard Fire Watch and Patrol Duties Questions and Answers 1 — Questions and Answers
Question 1: An F-02 Fireguard is required to maintain a patrol record, often in a logbook. Which of the following is a mandatory requirement for these records according to FDNY regulations?
- Entries must be made in black or blue ink and retained on-site for a minimum of 3 years. (Correct answer)
- A digital copy must be emailed to the fire station at the end of each shift.
- The logbook must be stored in a locked safe when the Fireguard is not on patrol.
- Only the Fire Safety Director is permitted to make entries in the logbook.
Correct answer: Entries must be made in black or blue ink and retained on-site for a minimum of 3 years.
FDNY Fire Code requires that patrol logs be kept on-site for a minimum of 3 years and that entries be made in black or blue ink. Corrections must be made with a single line through the error, initialed, and dated; white-out is not permitted.
Question 2: During a routine patrol in a shelter, you discover a portable fire extinguisher that is not properly mounted and is sitting on the floor behind a stack of chairs. What is the most appropriate action for the F-02 Fireguard to take?
- Confiscate the extinguisher and take it to the supervisor's office for review.
- Ensure the extinguisher is properly mounted in a visible, accessible location and document the correction. (Correct answer)
- Leave the extinguisher where it is but make a note in the logbook to have maintenance look at it.
- Place a sign next to the extinguisher indicating that it is out of service.
Correct answer: Ensure the extinguisher is properly mounted in a visible, accessible location and document the correction.
A primary duty of a Fireguard is to identify and, when possible, correct fire safety hazards. An obstructed or improperly mounted fire extinguisher is a common violation. The guard should correct the situation by ensuring it is properly placed and accessible, then document the finding and correction in their patrol log.
Question 3: A fire drill is being conducted at the shelter where you are on duty as an F-02 Fireguard. Which of the following best describes your primary role during the drill?
- Operating the fire command station and making public announcements.
- Activating and then immediately resetting the fire alarm system to test its function.
- Timing the evacuation speed of occupants and reporting it to the building manager.
- Assisting in the orderly evacuation of occupants and ensuring exit paths remain clear. (Correct answer)
Correct answer: Assisting in the orderly evacuation of occupants and ensuring exit paths remain clear.
The responsibilities of an F-02 Fireguard explicitly include assisting with the evacuation of shelter occupants and employees during emergency drills and actual emergencies. Their role is to help guide people to safety and ensure the process is orderly.
Question 4: While on patrol, an F-02 Fireguard must be knowledgeable about the different classes of fire. A fire involving energized electrical equipment is classified as which type of fire?
- Class A
- Class B
- Class C (Correct answer)
- Class K
Correct answer: Class C
Class C fires involve energized electrical equipment. Using the wrong type of extinguisher, such as water-based (Class A), on a Class C fire can create a severe shock hazard.
Question 5: An F-02 Fireguard's Certificate of Fitness (C of F) is valid for a specific period before it must be renewed. According to FDNY regulations, how long is the F-02 C of F valid?
- One year from the date of issuance.
- Five years from the date of issuance.
- Indefinitely, as long as the holder is employed as a Fireguard.
- Three years from the date of issuance. (Correct answer)
Correct answer: Three years from the date of issuance.
The FDNY stipulates that the F-02 Certificate of Fitness is valid for a period of three years, after which it must be renewed.
Question 6: In a scenario where a building's fire alarm system is out of service, an F-02 Fireguard is conducting a fire watch. Besides patrolling, what is a critical tool the Fireguard must have to alert occupants in case of a fire?
- A copy of the building's blueprints.
- A personal cell phone to call 911.
- A method for making an audible alarm, such as a megaphone or air horn. (Correct answer)
- A master key to all rooms in the shelter.
Correct answer: A method for making an audible alarm, such as a megaphone or air horn.
When a fire alarm system is out of service, the Fireguard must have a reliable way to notify occupants of an emergency. The FDNY study material specifies that if pull stations are not operational, procedures must be in place to notify occupants, which often includes a megaphone, air horn, or other means to create a loud, audible alarm throughout the patrol area.
An F-02 Fireguard is required to maintain a patrol record, often in a logbook.
Which of the following is a mandatory requirement for these records according to FDNY regulations?