F-01 - F-01 Fireguard Impairment Coordinator Role Questions and Answers 1 — Questions and Answers
Question 1: An Impairment Coordinator has been notified of an unplanned shutdown of a building's sprinkler system. Which of the following is one of the first and most critical responsibilities of the Impairment Coordinator?
- Personally conduct the first four hours of the fire watch.
- Determine the extent and expected duration of the out-of-service condition. (Correct answer)
- Immediately order an evacuation of the entire building.
- Contact the building's insurance carrier to file a preliminary report.
Correct answer: Determine the extent and expected duration of the out-of-service condition.
According to FDNY regulations, before taking other major steps, the Impairment Coordinator must first assess the situation by determining the scope and expected timeline of the impairment to understand the level of risk involved.
Question 2: Once a fire protection system is restored to service, which of the following actions must the Impairment Coordinator ensure is completed?
- The F-01 Fire Guard files the final report with the FDNY.
- The building owner is billed for the fire watch service.
- Necessary inspections and tests are conducted to verify the system is operational. (Correct answer)
- A new fire safety plan is drafted and submitted for approval.
Correct answer: Necessary inspections and tests are conducted to verify the system is operational.
The NYC Fire Code specifies that when an out-of-service system is restored, the Impairment Coordinator is responsible for verifying that it is fully operational through necessary inspections and tests before notifying stakeholders and removing tags.
Question 3: Who is responsible for placing an impairment tag at the Fire Department Connection (FDC) and system control valves when a sprinkler system is taken out of service?
- The first-arriving FDNY unit.
- The building owner or their representative.
- The F-01 Fire Guard on duty.
- The Impairment Coordinator. (Correct answer)
Correct answer: The Impairment Coordinator.
The Impairment Coordinator is responsible for ensuring that tags are placed at key locations, including the FDC and control valves, to indicate that a system is out of service.
Question 4: In a planned removal from service of a fire alarm system, which of the following is a primary duty of the Impairment Coordinator BEFORE the system is taken offline?
- Notify the building occupants, central station, and insurance carrier. (Correct answer)
- Train building occupants on evacuation procedures.
- Conduct a full fire drill for the affected areas.
- Repair any known deficiencies in the system.
Correct answer: Notify the building occupants, central station, and insurance carrier.
The Impairment Coordinator must ensure all required parties, including occupants (if the outage will be long), the central station, and the insurance carrier, are notified before a planned impairment begins.
Question 5: A building's standpipe system will be out of service for 36 hours for a major repair. The Impairment Coordinator's responsibilities include arranging for a fire watch. Who is directly responsible for performing the patrols for the majority of this period?
- The Impairment Coordinator.
- Any trained and knowledgeable person designated by the owner.
- A Certificate of Fitness holder for F-01 Fire Guard. (Correct answer)
- The building's maintenance supervisor.
Correct answer: A Certificate of Fitness holder for F-01 Fire Guard.
While the Impairment Coordinator is responsible for arranging the fire watch, FDNY regulations state that after the initial four hours of an impairment, the patrols must be conducted by individuals holding an F-01 Certificate of Fitness.
Question 6: If a building owner does not designate a specific person to be the Impairment Coordinator, who is automatically considered to have assumed the role and its responsibilities?
- The senior F-01 Fire Guard on site.
- The head of the building's security team.
- The building owner. (Correct answer)
- The fire safety/evacuation director.
Correct answer: The building owner.
According to the NYC Fire Code, the building owner is ultimately responsible. If they do not specifically designate an Impairment Coordinator, the owner themselves is considered the Impairment Coordinator by default.
An Impairment Coordinator has been notified of an unplanned shutdown of a building's sprinkler system.
Which of the following is one of the first and most critical responsibilities of the Impairment Coordinator?