CLC CLC Specimen Collection, Handling & Pre-Analytical Processes 1 — Questions and Answers
Question 1: The pre-analytical phase of laboratory testing is considered the most error-prone phase. Which of the following is a common pre-analytical error?
- Incorrect calibration of instrument
- Hemolyzed specimen due to improper collection technique (Correct answer)
- Transcription error in result reporting
- Reagent lot-to-lot variation
Correct answer: Hemolyzed specimen due to improper collection technique
Hemolysis from improper venipuncture technique is one of the most frequent pre-analytical errors, which can falsely alter results for multiple analytes.
Question 2: According to CLSI guidelines, what is the recommended order of draw when collecting multiple tubes during a single venipuncture?
- EDTA → SST → citrate → heparin
- Blood culture → citrate → SST → heparin → EDTA (Correct answer)
- SST → EDTA → citrate → blood culture
- Heparin → EDTA → SST → citrate
Correct answer: Blood culture → citrate → SST → heparin → EDTA
CLSI GP41 specifies the order: blood cultures first, then citrate (blue), then SST or plain red, then heparin (green), then EDTA (lavender) to prevent cross-contamination between additives.
Question 3: A laboratory consultant reviews rejection criteria and notes that a urine specimen for culture arrived in the laboratory 4 hours after collection without refrigeration. What is the appropriate action?
- Process the specimen and note the delay
- Reject the specimen and request a new collection (Correct answer)
- Centrifuge immediately and process
- Add a preservative and proceed
Correct answer: Reject the specimen and request a new collection
Unrefrigerated urine held more than 2 hours before culture is typically rejected because bacterial overgrowth invalidates culture results.
Question 4: Which anticoagulant tube is the correct choice for a prothrombin time (PT/INR) test?
- EDTA (lavender top)
- Heparin (green top)
- Sodium citrate (blue top) (Correct answer)
- Serum separator tube (gold top)
Correct answer: Sodium citrate (blue top)
Sodium citrate (blue top) tubes are required for coagulation studies including PT/INR because citrate preserves clotting factors by chelating calcium.
Question 5: A phlebotomist collects a citrate tube but it is only 80% full. What is the most significant concern with this specimen?
- Insufficient volume for the analyzer
- Altered blood-to-anticoagulant ratio affecting coagulation results (Correct answer)
- Risk of clot formation in the tube
- Tube vacuum loss
Correct answer: Altered blood-to-anticoagulant ratio affecting coagulation results
Citrate tubes require a precise 9:1 blood-to-anticoagulant ratio; underfilling alters this ratio and leads to falsely prolonged coagulation results.
Question 6: Which specimen type is most appropriate for measuring ionized calcium?
- Serum (SST tube, spun)
- Whole blood collected in a heparinized syringe (Correct answer)
- Plasma from EDTA tube
- 24-hour urine collection
Correct answer: Whole blood collected in a heparinized syringe
Ionized calcium is best measured in heparinized whole blood collected anaerobically, as EDTA chelates calcium and serum requires careful handling to avoid pH changes.
The pre-analytical phase of laboratory testing is considered the most error-prone phase.
Which of the following is a common pre-analytical error?