CET Cheat Sheet 2026
The 30 highest-yield CET facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
100 questions
180 min time limit
70.00% to pass
- What is the PRIMARY purpose of continuing education requirements in Accessibility & ADA Compliance for CET professionals? → Maintaining current knowledge and competency as the field evolves
- Which standard of practice is MOST important for ensuring quality in Governor & Overspeed Protection? → Following evidence-based protocols while adapting to specific circumstances
- Under ASME A17.1, what is the minimum width of a firefighters' emergency key switch box access opening? → 2 inches
- What is the typical step riser height used on a standard escalator? → 8 inches
- Which safety switch stops an escalator when the skirt panel is deflected inward by an obstruction? → Skirt obstruction switch
- Per ASME A17.1, the minimum conductor size permitted for elevator power circuits is: → 14 AWG, ensuring adequate current capacity and mechanical strength
- What is the purpose of the terminal stopping device (final limit switch) in a traction elevator? → Stops the car if it passes beyond normal travel limits
- Under the ADA Standards for Accessible Design, elevator car position indicators must be provided and must include which of the following for accessibility? → Audible signal and visible display announcing each floor
- What is the PRIMARY purpose of continuing education requirements in Modernization & Upgrades for CET professionals? → Maintaining current knowledge and competency as the field evolves
- What is the standard color coding for door safety edge wiring on a DC motor-driven door operator? → There is no standard color code — refer to the wiring diagram
- What is the function of a 'door reversal device' in the elevator door control circuit? → Detects an obstruction and signals the door operator to reverse from closing to opening
- What does 'selective modernization' mean in the context of elevator upgrades? → Upgrading specific components while retaining other existing parts that still meet code
- In Governor & Overspeed Protection, what is the FIRST step a CET professional should take when encountering a new case or situation? → Conduct a comprehensive assessment and gather all relevant information
- In an elevator safety circuit, what is a 'series circuit' configuration used for? → Ensuring that ALL safety contacts must be closed for the elevator to run
- What is the PRIMARY purpose of continuing education requirements in Fire Service & Emergency Operations for CET professionals? → Maintaining current knowledge and competency as the field evolves
- What is the standard minimum number of hoist ropes required for a traction elevator under ASME A17.1? → 3
- A newly modernized elevator fails its 'full load, full speed' stopping distance test. Which component is MOST likely misadjusted? → Electromagnetic brake torque
- A passenger elevator installed in a new building covered by ADA must have a minimum weight capacity of how many pounds? → 1,500 lbs (680 kg)
- When replacing hydraulic elevator cylinder packing (seals), the technician must FIRST: → Relieve all system pressure and support the car on blocking before disassembly
- Which maintenance task helps prevent 'roping' wear patterns on traction sheaves? → Rotating ropes end-for-end at prescribed intervals
- A governor that is set to trip at too low a speed relative to rated speed would most likely cause: → Safeties engaging during normal operation
- Which edition of the ICC/ANSI A117.1 standard governs accessible elevator cab dimensions used in ADA compliance? → The edition adopted by the local jurisdiction
- According to ASME A17.1, the maximum pressure above which a hydraulic elevator relief valve must open is: → 125% of working pressure
- According to ADA Standards for Accessible Design, what is the minimum clear floor area required inside an elevator cab for a standard side-entry configuration? → 48 inches wide × 51 inches deep
- What is the purpose of the 'independent service' mode on an elevator in relation to emergency operations? → It removes the elevator from normal group dispatching for single-car manual control
- A traction elevator makes a loud 'thud' when stopping at floors. The MOST probable mechanical cause is: → Worn brake lining causing the brake to apply too quickly
- Which standard of practice is MOST important for ensuring quality in Door Operators & Interlocks? → Following evidence-based protocols while adapting to specific circumstances
- Under ADA, elevator hall call buttons must be located at what maximum height above the finished floor? → 54 inches for side reach and 48 inches for forward reach
- A hydraulic elevator with a buried single-bottom cylinder must have the cylinder casing inspected for leaks. The MOST reliable method is: → Installing a monitoring tube to detect fluid accumulation inside the casing
- What is the purpose of a hydraulic elevator 'load-weighing' device in a variable-speed system? → To adjust pump output pressure and flow to optimize performance based on car load
Turn these facts into recall:
Was this helpful?